Lenovo RT1.5kVA Product Manual

Lenovo RT1.5kVA Product Manual

2u rack or tower uninterruptible power supplies
Hide thumbs Also See for RT1.5kVA:

Advertisement

RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower

Uninterruptible Power Supplies

Product Guide
The RT1.5kVA, RT2.2kVA, and RT3kVA 2U Rack or Tower Uninterruptible Power Supply (UPS) offerings
provide extended power protection with increased efficiency and simplified power management to
safeguard the high-availability of Lenovo server environments. With efficiency ratings of up to 99%, these
compact 2U rack or tower designs can help reduce energy usage without compromising performance or
reliability.
The 2U Rack or Tower UPS units can be installed in a data center rack cabinet or can be used as tower
UPS units in office and distributed IT environments where extended power protection is required.
The 2U Rack UPS unit with the Extended Battery Module is shown in Figure 1.
Figure 1. 2U Rack UPS unit (top) with Extended Battery Module (bottom)
Did you know?
2U Rack or Tower UPS units feature Advanced Battery Management (ABM) technology that uses a unique,
three-stage charging technique that significantly extends battery service life and optimizes recharge time
compared to traditional charging methods.
2U Rack or Tower UPS units can enhance system availability with individual receptacle groups or load
segments that can be programmed and controlled, which allows mission-critical devices to be prioritized
during shutdown to preserve battery run time if there is a prolonged power outage.
2U Rack or Tower UPS units come standard with UPS Power Manager software that integrates seamlessly
with the major virtualization platforms, which enables you to view and manage your entire power system
from your current dashboard. It also triggers live migration during power outages and avoids data loss by
gracefully shutting down virtual machines and hosts in a cluster if there is an extended power outage.
Click here to check for updates
RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo RT1.5kVA

  • Page 1: Uninterruptible Power Supplies

    Uninterruptible Power Supplies Product Guide The RT1.5kVA, RT2.2kVA, and RT3kVA 2U Rack or Tower Uninterruptible Power Supply (UPS) offerings provide extended power protection with increased efficiency and simplified power management to safeguard the high-availability of Lenovo server environments. With efficiency ratings of up to 99%, these compact 2U rack or tower designs can help reduce energy usage without compromising performance or reliability.
  • Page 2: Ordering Information

    RT3kVA 2U Rack or Tower UPS (100-125VAC): 2.5 m (8 ft) line cord with NEMA L5-30P plug The RT1.5kVA, RT2.2.kVA, and RT3kVA 200-240 V UPS models do not ship with line cords. Table 2 and Table 3 list the compatible line cords which are suitable for RT1.5kVA and RT2.2kVA/RT3kVA 200-240 V UPS models, respectively.
  • Page 3 Network Management Card (NMC) installed. The NMC provides convenient, over-the-network UPS remote monitoring and management through a standard web browser or UPS Power Manager software. Figure 2 shows the UPS NMC. RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 4 Connects to an NMC through an RJ-45 CAT5 Ethernet cable (1 m cable included with the EMP) Can be located up to 20 m (65.6 ft) from the UPS RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 5 9 hours of downtime a year, not to mention brownouts and other power quality problems. Selecting the right UPS can help protect against these potentially costly incidents. The RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower UPS units are most effective against power failures, power sags, power surges, under-voltage, and over-voltage.
  • Page 6: Technical Specifications

    Group 2: 2x 5-15R Group 2: 2x 5-20R Group 2: 2x 5-20R Batteries Battery type Valve Regulated Lead Acid (VRLA): Maintenance-free, sealed, leak-proof Battery capacity 7.2 Ah 9 Ah 9 Ah RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 7 Optional (See Table 3) Optional (See Table 3) Electrical output Output voltage settings 200/208/220/230/240 V AC 200/208/220/230/240 V AC 200/208/220/230/240 V AC Output frequency 50/60 Hz 50/60 Hz 50/60 Hz RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 8 The following two tables list the expected period that the 2U Rack or Tower UPS models operate based only on batteries, depending on the load. Note: Battery backup times are approximate and can vary with equipment, configuration, battery age, and temperature. RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 9 1920 W RT3kVA 2U Rack or Tower UPS (100-125VAC) 270 W 540 W 810 W 1080 W 1350 W 1620 W 1890 W 2160 W 2430 W 100% 2700 W RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 10 1980 W RT3kVA 2U Rack or Tower UPS (200-240VAC) 270 W 540 W 810 W 1080 W 1350 W 1620 W 1890 W 2160 W 2430 W 100% 2700 W RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 11: Connectors And Controls

    Identification: Displays the machine type, model, and serial number of the unit, and the firmware level of the UPS, including the optional NMC’s firmware level and IP address, if installed. RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 12 The following figure shows the rear view of the RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (55941AX). Figure 5. Rear view of the RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (55941AX) The following figure shows the rear view of the RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (55942AX).
  • Page 13 Figure 7. Rear view of the RT3kVA 2U Rack or Tower UPS (100-125VAC) (55943AX) The following figure shows the rear view of the RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (55941KX). Figure 8. Rear view of the RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (55941KX)
  • Page 14 The following figure shows the rear view of the RT3kVA 2U Rack or Tower UPS (200-240VAC) (55943KX). Figure 10. Rear view of the RT3kVA 2U Rack or Tower UPS (200-240VAC) (55943KX) RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 15: Physical Specifications

    The following figure shows the rear view of the 1.5kVA/2.2kVA (top) and 3kVA (bottom) 2U Rack or Tower Extended Battery Modules. Figure 11. Rear view of the 1.5kVA/2.2kVA (top) and 3kVA (bottom) 2U Rack or Tower Extended Battery Modules Physical specifications RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 16: Operating Environment

    Agency approvals The 2U Rack or Tower UPS units conform to the following regulations: CSA or cUL CE Mark GOST BSMI Taiwan CB Report VCCI C-Tick (Australia) IRAM (Argentina) Warranty RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 17: Management Software

    Gold key license (up to 600 devices can be managed) The purchase of a Silver or Gold license adds additional management features not found in the Basic license. The following table shows the UPM licenses and features for each license when managing Lenovo UPS units.
  • Page 18 The UPM software solution ensures system uptime and data integrity by allowing you to monitor, manage, and control the devices on your network remotely. The UPM user interface is shown in the following figure. RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 19: Ups Power Protector

    UPS, which saves all work-in-progress and ensures data integrity. UPP's user interface provides detailed information about connected servers and UPS units through USB and serial or network communication. The UPP user interface is shown in the following figure. RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 20: Supported Servers

    UPS, refer to the products user manual for the maximum power draw. For additional technical information on the UPS line cords, outlets and grouping refer to the UPS Technical Reference, https://support.lenovo.com/docs/UM104477 Supported rack cabinets RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 21: Related Publications And Links

    Power Configurator Tool: http://support.lenovo.com/au/en/documents/LNVO-PWRCONF Installation and User's Guide - 2U Rack or Tower UPS http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5096504 Network Management Card User Guide http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085199 US Announcement Letter http://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS114-100 Related product families RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 22 Related product families Product families related to this document are the following: Uninterruptible Power Supplies RT1.5kVA, RT2.2kVA and RT3kVA 2U Rack or Tower Uninterruptible Power Supplies...
  • Page 23 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 24 Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at http://www3.lenovo.com/us/en/legal/copytrade/. The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo®...