hit counter script

Cisco MDS 9216 Configuration Manual page 95

Mds 9000 series san volume controller
Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

Chapter 10
Configuring a Dual Fabric SAN Environment
switch2(config-ivr-zone)# member pwwn 27:8d:00:05:30:00:33:2a vsan 2
switch2(config-ivr-zone)# member pwwn 27:89:00:05:30:00:33:2a vsan 2
switch2(config-ivr-zone)# member pwwn 20:07:00:a0:b8:0f:6c:34 vsan 12
switch2(config-ivr-zone)# exit
Step 11
Set up the IVR zone to allow SVC initiators in Switch 2 to talk to target port in Switch 1.
switch2(config)# ivr zone name ivr_12_2
switch2(config-ivr-zone)# member pwwn 23:30:00:05:30:00:8d:e2 vsan 12
switch2(config-ivr-zone)# member pwwn 23:31:00:05:30:00:8d:e2 vsan 12
switch2(config-ivr-zone)# member pwwn 20:06:00:a0:b8:0f:6c:34 vsan 2
switch2(config-ivr-zone)# exit
Set up the IVR zone to allow SVC management on both switches to talk to each other.
Step 12
switch2(config)# ivr zone name ivr_4_14
switch2(config-ivr-zone)# member pwwn 27:90:00:05:30:00:33:2a vsan 4
switch2(config-ivr-zone)# member pwwn 27:8f:00:05:30:00:33:2a vsan 4
switch2(config-ivr-zone)# member pwwn 23:34:00:05:30:00:8d:e2 vsan 14
switch2(config-ivr-zone)# member pwwn 23:35:00:05:30:00:8d:e2 vsan 14
switch2(config-ivr-zone)# exit
Create the IVR zone set with the IVR zones and activate the IVR zone set.
Step 13
switch2(config)# ivr zoneset name ivr_zs
switch2(config-ivr-zoneset)# member ivr_2_12
switch2(config-ivr-zoneset)# member ivr_12_2
switch2(config-ivr-zoneset)# member ivr_4_14
switch2(config-ivr-zoneset)# exit
switch2(config)# ivr zoneset activate name ivr_zs
Zone set activation is now initiated. Check inter-VSAN zoneset status.
If any VSANs are configured to permit the default-zone, then you must use the force option to activate
the IVR zone set
switch1(config)# ivr zoneset activate name ivr_zs force
Zone set activation is now initiated. Check inter-VSAN zoneset status.
Bring up all interfaces, including the E-port, for the IVR transit VSAN.
Step 14
switch2(config)# interface fc7/2, fc7/3
switch2(config-if)# no shutdown
switch2(config-if)# exit
switch2(config)# interface fc7/17
switch1(config-if)# switchport trunk mode on
switch1(config-if)# switchport mode E
switch2(config-if)# no shutdown
switch2(config-if)# switchport trunk allowed vsan 20
switch2(config-if)# exit
You have now configured the second fabric for the dual fabric SAN environment displayed in
Figure
78-16119-01, Cisco MDS SAN-OS Release 1.3
10-1.
Cisco MDS 9000 Family SAN Volume Controller Configuration Guide
Sample Configuration
10-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series

Table of Contents