Chapter 6
Configuring Hosts
switch(config-zone)# member pwwn 20:06:00:0b:fd:44:68:c2
switch(config-zone)# end
switch#
Create a SVC host using this pWWN
Step 8
switch# svc-config
switch(svc)# show cluster SampleCluster host candidate
-------------------------------------------------------------------------------
id
-------------------------------------------------------------------------------
1
2
switch(svc)# cluster config SampleCluster
switch(svc-cluster)# host add iscsi1 hostport 21:00:00:e1:8b:09:e7:04
switch(svc-cluster)# host add iscsi2 hostport 20:06:00:0b:fd:44:68:c2
Map VDisks to both hosts.
Step 9
switch(svc-cluster)# host name iscsi1
switch(svc-cluster-host)# map vdisk crm-data
switch(svc-cluster-host)# exit
switch(svc-cluster)# host name iscsi2
switch(svc-cluster-host)# map vdisk crm-data
switch(svc-cluster-host)# end
switch#
Start the iSCSI clients on both hosts and verify that the sessions come up using the show iscsi session
Step 10
command.