Preface
______________
Properties
______________
Parameters
______________
Diagnostics
______________
Analog value representation
______________
Connecting
1
2
3
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Siemens 6ES7134-4JB00-0AB0

  • Page 1 Preface SIMATIC ET 200S distributed I/O 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) ______________ Properties ______________ Parameters SIMATIC ______________ Diagnostics ET 200S distributed I/O 2AI TC ST analog electronic ______________ Analog value representation module (6ES7134-4JB00-0AB0) ______________ Connecting Manual 04/2007 A5E01076883-01...
  • Page 2 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 3: Preface

    Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http://www.siemens.com/automation/partner...
  • Page 4 ● The bulletin board, a worldwide knowledge exchange for users and experts. ● Your local contact for Automation & Drives in our contact database. ● Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 5 Table of contents Preface ..............................3 Properties ..............................7 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) .............7 Parameters .............................. 13 Parameters...........................13 Parameter description........................14 Diagnostics .............................. 15 Diagnostics using LED display.....................15 Error types............................16 Analog value representation ........................17 Introduction ..........................17 Analog value representation for measuring range with SIMATIC S7 ..........17 Measuring ranges ........................19...
  • Page 6 Table of contents 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 7: Properties

    Properties 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Properties ● 2 inputs for thermocouple or voltage measurement ● Input ranges: – Voltage measurement: ± 80 mV, resolution 15 bits + sign – Thermocouples: Type E, N, J, K, L, S, R, B, T, resolution 15 bits + sign ●...
  • Page 8 Properties 1.1 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Usable terminal modules Usable terminal modules for 2AI TC ST (6ES7134-4JB00-0AB0) TM-E15C26-A1 TM-E15C24-A1 TM-E15C24-01 TM-E15C23-01 Spring terminal (6ES7193-4CA50- (6ES7193-4CA30- (6ES7193-4CB30- (6ES7193-4CB10- 0AA0) 0AA0) 0AA0) 0AA0) TM-E15S26-A1 TM-E15S24-A1 TM-E15S24-01 TM-E15S23-01 Screw-type terminal...
  • Page 9 Properties 1.1 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) 2AI TC ST technical data (6ES7134-4JB00-0AB0) Dimensions and weight Width (mm) Weight Approx. 40 g Module-specific data Supports isochronous operation Number of inputs Cable length Shielded • Max. 50 m Parameter length...
  • Page 10 Properties 1.1 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Suppression of interference, limits of error Noise suppression for f = n x (f1 ± 1 %), (f1 = interference frequency) Common-mode interference (U • Min. 90 dB Common mode interference •...
  • Page 11 Compensation of thermocouples with a compensating box As well as the error limits of the 2AI TC ST electronic module (see Table "Technical data 2AI TC ST (6ES7134-4JB00-0AB0)" in this chapter) you must also take the accuracy of the compensating box into account.
  • Page 12 Properties 1.1 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 13: Parameters

    TC-EL Type L (Fe-Cu-Ni) • Only with thermocouples. A parameter assignment error occurs when the wire break diagnosis is enabled in the voltage measuring range. The module does not start up. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 14: Parameter Description

    The following diagrams show the step response with the various smoothing factors in relation to the number of module cycles. Figure 2-1 Smoothing with the 2AI TC ST 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 15: Diagnostics

    Event (LED) Cause Remedy No configuration or incorrect Check the parameter module plugged in. No load assignment. Check the load voltage.present There is a voltage. Evaluate the diagnostic message. diagnostics. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 16: Error Types

    Reference channel error is not reported if the RTD module is not parameterized in the GSD file using the PT100 Climatic. This applies to IM151-1 HIGH FEATURE (6ES7151-1BA00-0AB0 or higher), IM151-7 CPU and IM151-3 PROFINET IO (6ES7151-3AA00-0AB0 or higher). 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 17: Analog Value Representation

    Analog value Bit number Significance of the bits Sign The sign (S) of the analog value is always in bit number 15: ● "0" → + ● "1" → – 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 18 S 0 0 0 0 0 0 0 0 0 0 0 1 x x 15 + sign S 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 19: Measuring Ranges

    Hexadecimal > 2070,0 32767 7FFF Overflow 2070,0 20700 50DC Overrange 1820,1 18201 4719 1820,0 18200 4718 Nominal range 0000 -0,1 FFFF Underrange -120,0 -1200 FB50 < -120,0 -32768 8000 Underflow 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 20 Units Range Decimal Hexadecimal > 1450,0 32767 7FFF Overflow 1450,0 14500 38A4 Overrange 1200,1 12010 2EEA 1200,0 12000 2EE0 Nominal range -210,0 -2100 F7CC < -210,0 - 32768 8000 Underflow 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 21 Type N in °C Units Range Decimal Hexadecimal > 1550,0 32767 7FFF Overflow 1550,0 15500 3C8C Overrange 1300,1 13001 32C9 1300,0 13000 32C8 Nominal range -270,0 -2700 F574 < -270,0 -32768 8000 Underflow 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 22 Type T in °C Units Range Decimal Hexadecimal > 540,0 32767 7FFF Overflow 540,0 5400 1518 Overrange 400,1 4001 0FA1 400,0 4000 0FA0 Nominal range -270,0 -2700 F574 < -270,0 -32768 8000 Underflow 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 23: Voltage Measuring Ranges

    "Overflow/underflow" diagnostics Measured value after leaving the • -32767 8000 • disabled underrange "Lower limit value undershot" • diagnostic message "Wire-break check" diagnostics Open input: Undefined measured • • disabled value 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 24: Effect On Analog Value Representation

    (e.g., wire break in measuring range ±20 mA), the SF LED on the module lights up and the diagnostics can be evaluated. With this status, the correct input values are sent to the DP master. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 25: Connecting

    The steps you have to take are described in this chapter. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 26 The following schematic representation illustrates the connection of isolated measuring encoders to the optically isolated analog input modules. ① Logic ② Backplane bus ③ Ground bus ④ Central grounding point ⑤ Recommended connection ⑥ Isolated measuring encoders 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 27 Connection of non-isolated measuring encoders to an optically isolated analog input module: ① Logic ② Backplane bus ③ Ground bus ④ Equipotential bonding conductor ⑤ Non-isolated measuring encoders 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 28: Connecting Thermocouples

    ET 200S terminal module. The compensating lines are made of the same material as the wires of the thermocouple. The supply lines are made of copper. Ensure the correct polarity when connecting. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 29 ● The power supply to the compensating box must be isolated. ● The power supply unit must have adequate interference filtering (by means of a grounded shielding winding, for example). 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 30 For both channels of the 2AI TC module, you can select "RTD" or "None" as the reference junction. If you select "RTD," the same reference junction (RTD channel) is always used for both channels. Figure 5-1 Compensation by means of the 2AI RTD 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 31 Example of assigning parameters of reference junctions Setup: For simplification, only RTD and TC modules are shown in the following figure: Figure 5-2 Example of assigning parameters of reference junctions 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 32 Reference junction number Type/range of measurement E0 (any) Type/range of measurement E1 TC-EL Type... Non-isolated thermocouples When you use non-isolated thermocouples, you must comply with the permitted common- mode voltage. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 33: Wiring Unused Channels Of The Analog Input Modules

    ● Use shielded wires to the sensors and actuators. ● Lay out the wire shields on the shield connection. ● Connect the shield connection to the ground bus with low impedance. 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 34 Connecting 5.4 Using the shield connection 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 35: Index

    Manual, 3 Service & Support, 4 Shield connection, 33 Smoothing, 14 Disposal, 3 Technical Support, 4 Internet Thermocouples, 28 Service & Support, 4 Training center, 4 Isolated measuring encoders, 26 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...
  • Page 36 Index 2AI TC ST analog electronic module (6ES7134-4JB00-0AB0) Manual, 04/2007, A5E01076883-01...

This manual is also suitable for:

Simatic et 200s

Table of Contents