Please read this manual before connecting the Digital Super Hybrid System and save this manual
for future reference.
Thank you for purchasing the Panasonic Model KX-TD500, Digital Super Hybrid System.
Digital Super Hybrid System
Programming Guide
Model No.
KX-TD500

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic KX-TD500

  • Page 1 L SUP Digital Super Hybrid System Programming Guide KX-TD500 Model No. Please read this manual before connecting the Digital Super Hybrid System and save this manual for future reference. Thank you for purchasing the Panasonic Model KX-TD500, Digital Super Hybrid System.
  • Page 2 Introduction Introduction This Programming Guide is designed to serve as a technical reference for the Panasonic Digital Super Hybrid System, KX-TD500. It provides step-by-step instructions for performing system programming using the Maintenance Console software for a PC. About the Other Manuals...
  • Page 3: Table Of Contents

    Table of Contents Table of Contents 1 Configuration..................5 1.1 Configuration........................6 1.2 Slot Assignment ......................7 1.3 Trunk Port Assignment ....................11 1.4 Extension Port Assignment..................13 1.5 VPS (DPT) Port Assignment ..................19 1.6 T1 Port Assignment......................25 1.7 E1 Port Assignment......................28 1.8 DISA Port Assignment ....................31 1.9 BRI Port Assignment ....................32 1.10 PRI Port Assignment....................35 2 System....................
  • Page 4: Table Of Contents

    Table of Contents 5.5 Quick Dialling ......................249 5.6 Account Code ......................250 5.7 Special Carrier Code ....................252 5.8 Waiting Second Dial Tone Code................253 5.9 Absent Message......................255 5.10 DISA/TIE User Code....................257 5.11 VPS Integration ....................... 259 5.12 Caller ID Modification ....................
  • Page 5: Configuration

    Configuration Section 1 Configuration Programming Guide...
  • Page 6 Configuration 1.1 Configuration Used to determine the basic system configuration. Programming Guide...
  • Page 7: Slot Assignment

    Configuration 1.2 Slot Assignment Assigns the type of service cards, inserted in the free slots in the basic and expansion shelves. Note • The DPH/DPHG card is not available in some countries/areas. Programming Guide...
  • Page 8 Configuration Parameter Card Type Default Blank Value Range Please refer to "Description/Function." Description/Function Specifies the type of service cards inserted in the free slots in the basic and expansion shelves. <Selection> None: Not assigned. AGC: Automatic Gain Control card BRI: ISDN Basic Rate Access Interface card DHLC: Digital Hybrid Line Circuit card DID: Direct Inward Dialling Trunk card DID-2W: Both-way Direct Inward Dialling Trunk card...
  • Page 9 Configuration Parameter Card Type Description/Function Notes • To change the current Card Type to a new one, delete the current setting first by selecting "None" and then assign a new Card Type. • CPU - Slot No.13 of the Basic Shelf is fixed to CPU (Central Processing Unit) card.
  • Page 10 Configuration Parameter Status Default — Value Range FAULT Description/Function Used to set the status of the service cards. INS (In-Service): The target service card is operating normally. OUS (Out-of-Service): Programming data for the target service card is entered, but the target service card is not assigned to the system.
  • Page 11: Trunk Port Assignment

    Configuration 1.3 Trunk Port Assignment Used to assign each trunk port in the system to one of up to 48 trunk groups. Parameter Card No. Default — Value Range XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the physical number of the trunk card and its type, which you are going to programme.
  • Page 12 Configuration Parameter Status Default — Value Range FAULT Description/Function Specifies the operating status of the trunk port. INS: The trunk port is In-Service. OUS: The trunk port is Out-of-Service. FAULT: The trunk port is defective. Reference None Programming Guide...
  • Page 13: Extension Port Assignment

    Configuration 1.4 Extension Port Assignment Used to set various parameters for extension ports. XDP extensions are on ports 9 through 16 of a DHLC card. Parameter Card No. Default — Value Range XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the physical number of the extension card and its type, which you are going to programme.
  • Page 14 DSS: Select this option when you connect a DSS console to the extension port. VPS (DPT): Select this option when a port of Panasonic Voice Processing System (one that supports DPT Integration) is connected to the extension port. PC Console: Select this option when you connect a PC Console to the extension port.
  • Page 15 Configuration Parameter Tel. Type Default (Display only) Value Range Please refer to "Description / Function." Description/Function Displays the model number of telephone set which is currently connected to the extension port. <Telephone type list> Unknown: Not connected or Single Line Telephone TD50300: PC Console T7130: APT with SP-PHONE, 1-Line Display (12-CO) T7020 / T7320: APT with SP-PHONE (12-CO)
  • Page 16 Configuration Parameter Tel. Type Description/Function Notes • Some telephones in the above list are not available depending on the destination area. • Some features of a KX-T7400/T7500 series PT do not function unless it is connected to a DLC or DHLC card whose LPR Version (ROM Version) is 1 or later.
  • Page 17 Configuration Parameter Parallel / XDP (DHLC card) Default Parallel Value Range 1. Parallel 2. XDP Description/Function Specifies whether to enable or disable "Parallelled Connection of PT and SLT" or "XDP (eXtra Device Port) Connection of DPT and SLT." Reference • 1.1 System Expansion (F/G) –...
  • Page 18 Configuration Parameter DN Refer Default — Value Range — Description/Function Displays the list of DNs/FDNs which are already assigned to the extensions / system resources. Reference None Programming Guide...
  • Page 19: Vps (Dpt) Port Assignment

    Configuration 1.5 VPS (DPT) Port Assignment Used to assign parameters for VPS (DPT) ports. Up to eight Panasonic Voice Processing Systems (VPSs) can be connected to the system. How to set up a TVP 1. Assignment of the card which will be connected to the VPS System.
  • Page 20 5. Synchronisation of the communication between the KX-TD500 System and the TVP. The KX-TD500 System begins synchronisation with the VPS when the step 4 is done. The "Power" LED of the VPS begins flashing at the same time. The LED will turn on after the synchronisation is completed.
  • Page 21 TVP200 TVP200-1 TVP300 Description/Function Specifies the model number of the Panasonic Voice Processing System which will be connected to the VPS card. Note • Please select "TVP200-1," if HDD (Hard Disc) Software Version of your TVP200 is 2.00 or later.
  • Page 22 Configuration Parameter [Ext No.1] DN Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the extension for B1 channel. Notes • This programme allows you to assign an extension number to each Voice Mail port. Since each port connected to the VPS provides two extensions, this enables you to assign extension numbers to each port.
  • Page 23 Configuration Parameter [Ext No.2] DN Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the extension for B2 channel. Notes • This programme allows you to assign an extension number to each Voice Mail port. Since each port connected to the VPS provides two extensions, this enables you to assign extension numbers to each port.
  • Page 24 Configuration Parameter DN Refer Default — Value Range — Description/Function Displays the list of DNs/FDNs which are already assigned to the extensions / system resources. Reference None Programming Guide...
  • Page 25: T1 Port Assignment

    Configuration 1.6 T1 Port Assignment Used to assign parameters for T1 ports. How to set up a T1 card 1. Insert T1 card into a free slot. Notes • T1 card should be installed in the free slot no. 1, 5 or 9 of each shelf. •...
  • Page 26 Configuration Parameter Card No. Default — Value Range XXX : T1 [ XXX : Card No. (101-314)] Description/Function Specifies the physical number of the T1 digital trunk card which you are going to programme. Reference • 1.2 Slot Assignment (P/G) Parameter Channel Type Default...
  • Page 27 Configuration Parameter Group No. Default Blank Value Range 1-48 or 1-128 Description/Function Channel Type : LCO, GCO, DID, TIE (E&M) Specifies the Trunk Group (1-48) to which the T1 port is assigned. Channel Type : OPX Specifies the Extension Group (1-128) to which the T1 port is assigned.
  • Page 28: E1 Port Assignment

    Configuration 1.7 E1 Port Assignment Used to assign parameters for E1 ports. How to set up an E1 card 1. Insert E1 card into a free slot. Notes • E1 card should be installed in the free slot no. 1, 5 or 9 of each shelf. •...
  • Page 29 Configuration Parameter Card No. Default — Value Range XXX : E1 [ XXX : Card No. (101-314)] Description/Function Specifies the physical number of the E1 digital trunk card which you are going to programme. Reference • 1.2 Slot Assignment (P/G) Parameter Channel Type Default...
  • Page 30 Configuration Parameter Receiver Type Default Undefined Value Range Undefined Pulse DTMF MFC-R2 Description/Function Specifies the dial type when receiving an incoming call. Undefined: Not assigned. Pulse: DP Signalling sending / receiving DTMF: DTMF Signalling sending / receiving MFC-R2: MFC-R2 Signalling sending / receiving (Digital signalling system-R2 only) Reference None...
  • Page 31: Disa Port Assignment

    Configuration 1.8 DISA Port Assignment Used to assign OGM group number for each DISA card. Parameter [Card No. 1-8] Location Default (Display only) Value Range 101-314 Description/Function Displays the slot number of the DISA card which you are going to programme.
  • Page 32: Bri Port Assignment

    Configuration 1.9 BRI Port Assignment Used to assign the parameters for BRI (Basic Rate Interface) ports. Parameter Card No. Default — Value Range XXX: BRI [XXX: Card No. (101-314)] Description/Function Specifies the physical number of the BRI card which you are going to programme.
  • Page 33 Configuration Parameter Type Default Value Range Qsig – Master Qsig – Slave Description/Function Specifies the type of each BRI port on a BRI port basis. Note • When you change the programming data, the status of the card must be made OUS (Out-of-Service), and then INS (In- Service).
  • Page 34 Configuration Parameter Group No. Default Value Range 1-48 or 1-128 Description/Function Type: CO, Qsig-Master, Qsig-Slave Specifies the Trunk Group (1-48) to which the BRI port is assigned. Type: EXT Specifies the Extension Group (1-128) to which the BRI port is assigned.
  • Page 35: Pri Port Assignment

    Configuration 1.10 PRI Port Assignment Used to assign the parameters for PRI (Prime Rate Interface) ports. Parameter Card No. Default — Value Range XXX: PRI23/PRI30 [XXX: Card No. (101–314)] Description/Function Specifies the physical number of the PRI23/PRI30 card which you are going to programme.
  • Page 36 Configuration Parameter Type Default Value Range Qsig – Master Qsig – Slave Description/Function Specifies the type of each PRI port on a PRI port basis. Notes • When you change the programming data, the status of the card must be made OUS (Out-of-Service), and then INS (In- Service).
  • Page 37 Configuration Parameter Group No. Default Value Range 1-48 or 1-128 Description/Function Type: CO, Qsig-Master, Qsig-Slave Specifies the Trunk Group (1-48) to which the PRI port is assigned. Type: EXT Specifies the Extension Group (1-128) to which the PRI port is assigned.
  • Page 38 Configuration Programming Guide...
  • Page 39: System

    System Section 2 System Programming Guide...
  • Page 40 System 2.1 System Used to assign parameters which affect system-wide operation. Programming Guide...
  • Page 41: Tenant

    System 2.2 Tenant Used to assign various parameters on a tenant (1-8) basis. Parameter Tenant No. Default Value Range Description/Function Specifies the tenant (1-8) which you are going to programme. Reference • 1.3 System Features (F/G) – Tenant Service Parameter Operator FDN Default Blank...
  • Page 42 System Parameter Alert Extension - Day / Night Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the destination extension which will be alerted by the system, if there is an extension user who did not respond to the Timed Reminder ringing (or Wake-Up Call).
  • Page 43 System Parameter Inter-tenant Calling (1 - 8) Default No check Value Range No check [Disallowed] Check [Allowed] Description/Function Specifies other tenant numbers to which extensions in this tenant can make a call. If no tenant numbers are checked in this field, extension users within this tenant cannot make a call to extensions in other tenants.
  • Page 44 System Parameter Lunch - Start (SUN-SAT) Default 12:00 PM Value Range Same as Day Description/Function Specifies the start time for Lunch Service. Reference • 1.3 System Features (F/G) – Night Service Parameter Lunch - End (SUN-SAT) Default 1:00 PM Value Range Same as Day Description/Function Specifies the end time for Lunch Service.
  • Page 45 System Parameter Music on Hold Source Default MUS1 Value Range None MUS1 MUS2 Tone Description/Function Specifies the Music Source port to be used for Music on Hold. Note • If "MUS2" is selected, the actual source depends upon the position of the switch located on the TSW card. "MUS2 (Music 2 jack)"...
  • Page 46 System Parameter System Speed Dialing Entries Max. Default Tenant No. 1:1000, Tenant No. 2:1000, Tenant Nos. 3-8:0 Value Range 0-1000 in 20 codes increments Description/Function Specifies the maximum number of Speed Dialling codes available for each tenant. Note • Up to 2000 Speed Dialling codes can be shared among tenants under the restriction of up to 1000 codes per tenant.
  • Page 47 System Parameter System Speed Dial TRS Level Override Default No check Value Range Check [Enable] No check [Disable] Description/Function Enables or disables "Toll Restriction Override for System Speed Dial Numbers" feature. If enabled (Check), all extension users in the tenant can make System Speed Dialling calls without toll restriction.
  • Page 48: Numbering Plan

    System 2.3 Numbering Plan Used to assign the leading digits of extension numbers, and feature numbers for system features. Parameter 1 1st Hundred Block Extension Default Value Range 1-2 digits consisting of 0-9 Description/Function Specifies the leading 1 or 2 digits of the extension number. Any number "0 through 9"...
  • Page 49 System Parameter 2 2nd Hundred Block Extension Default Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1. Reference • 1.3 System Features (F/G) – Flexible Numbering Parameter 3 3rd Hundred Block Extension Default Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1.
  • Page 50 System Parameter 7 7th Hundred Block Extension Default Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1. Reference • 1.3 System Features (F/G) – Flexible Numbering Parameter 8 8th Hundred Block Extension Default Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1.
  • Page 51 System Parameter 11-16 11th Hundred Block Extension - 16th Hundred Block Extension Default Blank Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1. Reference • 1.3 System Features (F/G) – Flexible Numbering Parameter 17 Operator Call Default 9: [SA], 0: Others Value Range...
  • Page 52 System Parameter 20 Speed Dialing - System Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for making a call using a System Speed Dialling number. Reference • 2.2.2 Easy Dialling (U/M) Parameter 21 Speed Dialing - Station Default Value Range 1-4 digits consisting of 0-9,...
  • Page 53 System Parameter 25 External Paging Answer / TAFAS Answer Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for answering paging announcements through External Pagers or TAFAS (Trunk Answer From Any Station) calls. Reference •...
  • Page 54 System Parameter 29 Group Call Pickup Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for answering a call ringing at another extension in the same Extension Group. Reference • 2.3.3 Answering a Call Ringing at Another Telephone (Call Pickup) (U/M) Parameter 30 Directed Call Pickup...
  • Page 55 System Parameter 33 Hold Retrieve - Trunk Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for retrieving a specific outside call held at another extension. Reference • 2.4.1 Holding a Call (U/M) Parameter 34 Redial Default Value Range...
  • Page 56 System Parameter 38 External Feature Access Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for sending a switchhook flash to a host PBX or Centrex system. This is useful when the host PBX offers, for example, "Call Waiting"...
  • Page 57 System Parameter 42 Call FWD - Do Not Disturb Set / Cancel Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling the Call Forwarding / Do Not Disturb feature. Reference •...
  • Page 58 System Parameter 46 Executive Busy Override Deny Set / Cancel Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling Executive Busy Override Deny feature. Reference • 2.7.9 Denying Other People the Possibility of Joining Your Conversation (Executive Busy Override Deny) (U/M) Parameter 47 Pickup Dialing Program / Set / Cancel...
  • Page 59 System Parameter 50 Station Lock Set / Cancel Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling Electronic Station Lockout feature. Reference • 2.5.4 Preventing Other People from Making Outside Calls Using Your Telephone (Electronic Station Lockout) (U/M) Parameter 51 Night Mode Set / Cancel...
  • Page 60 System Parameter 54 Live Call Screening Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling Live Call Screening feature. Reference • 2.8.3 If a Voice Processing System is Connected (U/M) Parameter 55 Call Log Incoming, Overwrite Mode Default...
  • Page 61 System Parameter 58 Login / Logout Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for Log-in / Log-out to / from the members of an Extension Group and Phantom Extensions. Reference • 2.5.5 Leaving a Group (Log-In/Log-Out) (U/M) Parameter 59 Automatic Callback Busy Cancel Default...
  • Page 62 System Parameter 62 MCID Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for turning on / off the MCID (Malicious Call Identification) feature. Reference • 2.7.15 Identifying Malicious Callers (Malicious Call Identification [MCID]) (U/M) Parameter 63-70 Quick dial 1 - Quick dial 8 Default...
  • Page 63 System Parameter 73 Remote FWD Cancel-Once Default Value Range 1-4 digits consisting of 0-9, or # Description/Function With this feature number, the Manager or the Operators can reach an extension that has set Call Forwarding. It is one time ("once") cancellation, not a permanent cancellation of Call Forwarding on the destination.
  • Page 64 System Parameter 77-92 Other PBX 01 - Other PBX 16 Default Blank Value Range 1-2 digits consisting of 0-9 Description/Function Specifies the leading 1 or 2 digits of the other PBX extension numbers. If you employ PBX code method for TIE calls, this programming is not required.
  • Page 65 System Parameter 96 CLIP / COLP Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for selecting a CLIP / COLP (Calling / Connected Line Identification Presentation) number for an outside line or an extension. Reference •...
  • Page 66 System Parameter 100 COS Primary Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting the COS Primary. Reference • 3.1.5 Changing Service Level of Extensions (Switching COS) (U/ Parameter 101 COS Secondary Default Value Range 1-4 digits consisting of 0-9,...
  • Page 67 System Parameter 104 Group FWD Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting/cancelling the Call Forwarding feature from one Incoming Group to another Incoming Group or Extension Group. Reference • 1.11 Transferring Features (F/G) –...
  • Page 68: Class Of Service (Cos)

    System 2.4 Class of Service (COS) 2.4.1 Class of Service (COS) 1/2 Used to assign the Class of Service (COS) parameters. Parameter COS No. Default Value Range 1-96 Description/Function Specifies the COS (1-96) which you are going to programme. Reference •...
  • Page 69 System Parameter TRS Level – Day / Night Default Value Range Description/Function Specifies the Toll Restriction level (1-8) for each COS number in Day / Night mode respectively. Reference • 1.6 Originating Features (F/G) – Toll Restriction Parameter Account Code Mode Default Optional Value Range...
  • Page 70 System Parameter Switching Day / Night Mode Default Disable Value Range Enable Disable Description/Function Enables or disables switching the Day / Night / Lunch / Break service on a Class of Service (COS) basis. Reference • 1.3 System Features (F/G) –...
  • Page 71 System Parameter Transfer to CO Default Disable Value Range Enable Disable Description/Function Enables or disables "Call Transfer to Trunk" feature. Reference • 2.4.3 Transferring a Call (U/M) Parameter Call FWD to CO/TIE Default Disable Value Range Enable Disable Description/Function Enables or disables "Call Forwarding to Trunk" feature. Reference •...
  • Page 72 System Parameter Call FWD Follow Me Default Enable Value Range Enable Disable Description/Function Enables or disables "Call Forwarding - Follow Me" feature. Reference • 2.5.1 Forwarding Your Calls (Call Forwarding) (U/M) Parameter Busy Override Default Disable Value Range Enable Disable Description/Function Enables or disables "Executive Busy Override"...
  • Page 73 System Parameter Released Link Operation Default Disable Value Range Enable Disable Description/Function Used to turn on / off "Released Link Operation" mode of the extension. When Released Link Operation is enabled, an extension user will be automatically released from a call (extension, outside) after transferring it to the destination, if the destination extension is idle.
  • Page 74 System Parameter Automatic Hold Default Disable Value Range Enable Disable Description/Function Used to turn on / off "Automatic Hold" feature. Reference • 1.10 Holding Features (F/G) – Automatic Hold—For Hold – Automatic Hold—For Transfer Parameter SDN COS Default Own Extension Value Range Own Extension Description/Function...
  • Page 75 System Parameter ISDN CFU / CFB / CFNR Default Disable Value Range Enable Disable Description/Function Enables or disables the ability of performing "Call Forwarding by ISDN Line, CFU (Call Forwarding Unconditional) / CFB (Call Forwarding Busy) / CFNR (Call Forwarding No Reply)" feature. Reference •...
  • Page 76 System Parameter Trunk Group No. 01-48 – Day / Night Default All: Check Value Range No check [Restricted] Check [Not restricted] Description/Function Specifies the trunk group (01-48) which the extension user can use for making an outside call in Day / Night mode respectively on a COS basis.
  • Page 77 System Parameter Secret Busy Override Default Disable Value Range Enable Disable Description/Function Enables or disables "Secret Busy Override" feature. Reference • 1.6 Originating Features (F/G) – Secret Busy Override • 2.11.5 Monitoring the Conversation (Secret Busy Override) (U/ Parameter Transferring CO dial tone (exempted from TRS) Default Enable Value Range...
  • Page 78 System Parameter Incoming Group FWD Default Disable Value Range Disable Own Group(s) Any Group Description/Function Enables or disables setting "Incoming Group FWD" feature. The extension allowed by this setting can set Call Forwarding feature to an Incoming Group so that all calls to the Incoming Group can be forwarded to specified Incoming Group or Extension Group.
  • Page 79: System Timer

    System 2.5 System Timer 2.5.1 System Timer 1/2 Used to assign various system timers. Parameter Hold Recall Time Default 60 s Value Range 0-240 s Description/Function Specifies the length of time in seconds that the system is to wait before alerting the extension user who held the call by Held Call Reminder ringing.
  • Page 80 System Parameter Transfer Recall Time Default 12 rings Value Range 0-48 rings Description/Function Specifies the number of rings before transfer recall occurs. If a transferred call is not answered before the programmed number of rings, the call returns to the extension user who originally transferred it or an Operator depending on the setting of "6.
  • Page 81 System Parameter Call Duration Count Start Time Default Value Range 0-60 s Description/Function Specifies the length of time in seconds the system is to wait after sending all dialling digits to the Central Office before starting the call duration count. Note •...
  • Page 82 System Parameter Intercept Time Default 12 rings Value Range 1-48 rings Description/Function Specifies the number of rings the system is to wait before activating IRNA (Intercept Routing No Answer) feature. If an incoming CO call directed to a single extension is not answered within this timer, IRNA redirects the call to another pre-programmed destination.
  • Page 83 System Parameter Extension-to-CO Line Call Duration Time Default 10 min Value Range 1-64 min Description/Function Specifies the maximum time allowed for a call with an outside party. This time limit can apply to outgoing CO calls only or both outgoing and incoming CO calls. This is determined by "5. Limited call duration"...
  • Page 84 System Parameter Automatic Redial Repeat Times Default 3 times: [NZ], 10 times: [HK], [SA], 4 times: Others Value Range 0-30 times Description/Function Specifies the number of times Automatic Redial is repeated. Automatic Redialling of the last dialled number, saved number or call log number is done up to the specified number of times.
  • Page 85 System 2.5.2 System Timer 2/2 Used to assign various system timers. Parameter Timed Reminder Ringing Time Default 30 s Value Range 30-240 s Description/Function Specifies the length of ringing time in seconds of the Timed Reminder alarm. Reference • 1.8 Ringing Features (F/G) –...
  • Page 86 System Parameter Call Parking Recall Time Default 60 s Value Range 0-1800 s Description/Function Specifies the length of time in seconds the system is to wait before alerting (Call Parking Recall) the extension who parked the call. Note • If "0" is specified, Call Parking Recall does not occur. Reference •...
  • Page 87 System Parameter DISA Delayed Answer Time Default 1 ring Value Range 0-6 rings Description/Function Specifies the number of rings the system is to wait after receiving a DISA call before answering it. Note • A DISA call is answered after a ringback tone is returned to the caller after the "DISA Delayed Answer Time"...
  • Page 88 System Parameter DISA IRNA Time Default 60 s Value Range 5-240 s Description/Function Specifies the length of time in seconds the system is to wait before activating IRNA (Intercept Routing No Answer) feature for DISA calls. If a DISA call directed to a single extension is not answered within this timer, the system redirects the DISA call to another pre- programmed IRNA destination.
  • Page 89 System Parameter Timed Reminder Arrive Wait Time Default 60 s Value Range 20-240 s Description/Function Specifies the interval time between each Timed Reminder/Remote Timed Reminder (Wake-Up Call) attempt. Reference • 1.8 Ringing Features (F/G) – Timed Reminder (Wake-Up Call) – Timed Reminder, Remote (Wake-Up Call) •...
  • Page 90: Local Hunt Sequence

    System 2.6 Local Hunt Sequence Specifies the trunk group hunt sequence to be used when an extension user attempts to make an outside call by dialling the feature number for "Local CO Line Access / ARS" or by pressing a Loop-CO key. Parameter Trunk Group No.
  • Page 91: Trunk To Trunk Restriction

    System 2.7 Trunk to Trunk Restriction Used to allow or restrict the trunk-to-trunk relay function (routing a trunk call from one Trunk Group to another) on a trunk group basis. Please refer to "TIE Line Network—Alternate Routing" of Section "3.1 TIE Line Features" in the Features Guide for further information.
  • Page 92: System Option

    System 2.8 System Option 2.8.1 System Option 1 Used to assign system option parameters (No.1 — No.10). Parameter 1. Sound source during transfer Default Music on Hold Value Range Ringback Tone Music on Hold Description/Function Used to determine whether the system sends "Music on Hold" or "Ringback Tone"...
  • Page 93 System Parameter 2. SLT On-hook with consulting held call Default Consulting Hold Value Range Consulting Hold Disconnect Description/Function Specifies the result of pressing the switchhook lightly and then replacing the handset during an outside call. This setting applies to SLT users only. Reference •...
  • Page 94 System Parameter 5. Limited call duration Default Both calls Value Range Outgoing call only Both calls Description/Function Limited call duration is a system programmable feature that disconnects an outside call when a specified timer expires. A warning tone is sent to the extension user 15 seconds, 10 seconds, and 5 seconds before the time limit.
  • Page 95 System Parameter 7. Checking dial *, # by toll restriction Default Check Value Range No check [Disable] Check [Enable] Description/Function Specifies whether or not the system checks the user-dialled " " and "#" during Toll Restriction procedure. Note • This assignment is required for certain Central Offices (COs) to prevent toll fraud.
  • Page 96 System Parameter 10. Station Speed Dialing Initial display Default Name Value Range Name Number Description/Function Specifies the initial display of a display DPT, such as KX-T7235 / KX-T7436 / KX-T7536, in Station Speed Dialling. Reference • 2.10.4 Using the KX-T7531, KX-T7533, KX-T7536 or KX- T7235 (U/M) 2.8.2 System Option 2 Used to assign system option parameters (No.11 –...
  • Page 97 System Parameter 12. Automatic adjustment of the clock using Caller ID information Default Value Range Description/Function Enables or disables the automatic adjustment of the clock by Caller ID information once a day. Reference • 1.5 Attended Features (F/G) – Caller ID Service Parameter 13.
  • Page 98 System Parameter 15. Special dial tone after setting feature Default Enable Value Range Enable Disable Description/Function If enabled, the system notifies the extension user by sending a special dial tone (Dial Tone 2) when one or more of the following features are assigned on his extension.
  • Page 99 System Parameter 17. Destination Busy - DISA Default Send busy tone Value Range Send busy tone Transferred to IRNA destination Description/Function Specifies the treatment of DISA callers when they dial a busy extension. Reference • 1.5 Attended Features (F/G) – Direct Inward System Access (DISA) Parameter 18.
  • Page 100 System Parameter 20. Off-hook Monitor Default Enable Value Range Enable Disable Description/Function Enables or disables "Off-hook Monitor" feature on a system-wide basis. This feature allows a PT user on a handset call to let other people around him monitor the call by pressing the SP-PHONE button.
  • Page 101 System Message Waiting lamp patterns (1/2) The available message waiting lamp patterns are as follows: 5.12 1.28 Pattern #01 5.12 1.28 Pattern #02 512 ms 5.12 1.28 Pattern #03 256 ms 2.56 768 ms Pattern #04 256 ms 2.56 512 ms Pattern #05 1.28 Pattern #06...
  • Page 102 System Message Waiting lamp patterns (2/2) 1.28 Pattern #07 256 ms 1.28 Pattern #08 1.28 Pattern #09 t=1.28 Pattern #10 t=1.28 Pattern #11 5.12 768 ms Pattern #12 256 ms Programming Guide...
  • Page 103 System Parameter 21. Illegal Number - DISA Default Send reorder tone Value Range Send reorder tone Transferred to IRNA destination Description/Function Specifies the treatment of the invalid DISA calls. Reference • 1.5 Attended Features (F/G) – Direct Inward System Access (DISA) Parameter 22.
  • Page 104 System Parameter 25. Pressing DSS key operation in CO talking Default Hold Value Range Disconnect Hold Description/Function If set to "Hold," the PT user engaged in a CO call can transfer the current call to another extension simply by pressing the DSS button associated with the destination extension.
  • Page 105 System Parameter 28. Trunk hunting mode Default Forced Value Range Forced Loop Detection Description/Function Specifies the trunk hunting mode. Forced: The system seizes a trunk line whether or not loop current is detected from the local CO. Loop Detection: The system seizes a trunk line after detecting loop current from the local CO.
  • Page 106 System 2.8.4 System Option 4 Used to assign system option parameters (No.31 – No.49). Parameter 31. Answering Call Waiting call by SLT hooking Default Disable Value Range Enable Disable Description/Function If enabled, an SLT user can answer a call waiting call simply by flashing the switchhook.
  • Page 107 System Parameter 33. FWD / DND lamp pattern Default FWD: Flash, DND: On Value Range FWD: Flash, DND: On FWD: On, DND: Flash Description/Function Specifies the lamp patterns of the FWD / DND button. Reference • 1.8 Ringing Features (F/G) –...
  • Page 108 System Parameter 36. Tone Mode Default Type-3: [SA], Type-4: [HK], Type-1: Others Value Range Type-1 Type-2 Type-3 Type-4 Type-5 Type-6 Type-7 Description/Function Specifies the Tone output type. Note • The change of this parameter is activated after resetting the system. Reference None Parameter...
  • Page 109 System Parameter 39. Extension CPC Signal Default None Value Range None, 16-240 ms in 16 ms increments Description/Function Specifies whether or not the system sends the CPC signal to an extension. Reference None Parameter 40. TSW Tone Selection Default TONE-A: [SA], TONE-C: Others Value Range TONE-A TONE-B...
  • Page 110 System Parameter 43. LCD Time Display Mode Default Value Range Description/Function Specifies the time display on the LCD in 12-hour or 24-hour notation. Reference • 1.17 Display Features (F/G) – Display, Date and Time Parameter 44. Hotel Application Default Disable Value Range Enable Disable...
  • Page 111 System Parameter 47. Tone Type for Outgoing Calls Default Busy + Reorder Value Range Busy + Reorder Busy Reorder Description/Function Specifies a tone type for outgoing calls. Reference None Parameter 48. Call Pickup with DSS S-CO key Default Disable Value Range Enable Disable Description/Function...
  • Page 112 System 2.8.5 System Option 5 Used to assign system option parameters (No. 50 - No. 60). Parameter 50. Dial / Ringback tone frequency Default Normal Value Range Normal Distinctive Description/Function Specifies the frequency of dial / ringback tone. Reference • 1.13 Audible Tone Features (F/G) –...
  • Page 113 System Parameter 51. Release of BRI/PRI line while on-hold when 'DISCONNECT' signal is received Default Release Value Range Release Don't Release Description/Function Specifies whether or not the system releases the ISDN BRI / PRI line, when receiving the line disconnection message from the ISDN Network while the line is placed on hold.
  • Page 114 System Parameter 53. TIE-CO/CO-TIE Line Call Duration Restriction Default Value Range Description/Function This parameter restricts the call duration of "TIE-to-CO and CO-to- TIE" call. If set to "Yes," the system disconnects the call when the system timer "CO-to-CO Line Call Duration Timer" expires. Reference •...
  • Page 115 System Parameter 55. Displaying charge fee on LCD including margin Default Value Range Description/Function Switches the charge fee LCD display to include the margin or not. When you select "Yes," it will be displayed on the LCD including the margin that was assigned in "Margin" in "5-15 Hotel" screen. Reference •...
  • Page 116 System Parameter 58. Release of BRI/PRI line while talking when 'DISCONNECT' signal is received Default Release: [HK], Don’t Release: Others Value Range Release Don't Release Description/Function Specifies whether or not the system releases the ISDN BRI / PRI line, when receiving the line disconnection message from the ISDN Network while the line is in talking.
  • Page 117 System 2.8.6 System Option 6 Used to assign system option parameters (No.61 – No.65). Parameter 61. Auto Answer with held call Default Disable Value Range Disable Enable Description/Function Specifies whether the PT user automatically answers the intercom call on Consultation Hold or not. Reference •...
  • Page 118 System Parameter 62. End of Pulsing (End of Identification) Signal Default None Value Range None 1-15 Description/Function Specifies the pulse dialling signal after the inter-digit timer expires. (Assignable only when "DR2" is specified in "Channel Type" programming and "MFC-R2" is specified in "Receiver Type" programming in Section "1.6 E1 Port Assignment.") Note •...
  • Page 119: Language Data

    2.9 Language Data Display Language The KX-TD500 System provides two different languages as the Display Language at the same time, which is shown on the display of a Panasonic Proprietary Telephone (PT). Each PT user can choose English (default) or Optional Language, so PTs on the same KX-TD500 System can display different languages.
  • Page 120 • You can upload the Language Data after uploading the system data. When system data upload is finished, the "Language Data Selection" dialogue box is displayed. Then you can upload the Language Data in the same way as described in <Uploading the Language Data to the KX-TD500 System>. Programming Guide...
  • Page 121: Group

    Group Section 3 Group Programming Guide...
  • Page 122 Group 3.1 Group Used to assign various group parameters. Programming Guide...
  • Page 123: Trunk Group

    Group 3.2 Trunk Group 3.2.1 Trunk Group 1/2 Used to assign parameters for each trunk group. Up to 48 trunk groups can be created in the system. Note • To support efficient utilisation of trunks, it is desirable to group them together in trunk groups according to a type of each trunk (Incoming Only, Outgoing Only or Both-Way) determined by the contract with the Central Office.
  • Page 124 Group Trunk Group Copy Used to copy a part of or all settings of a certain Trunk Group to all other Trunk Groups at a time. You can also specify one or several Trunk Groups as the copy destination. Copying the Trunk Group Parameters to Other Trunk Groups 1.
  • Page 125 Group Parameter Group No. Default Value Range 1-48 Description/Function Specifies the trunk group (1-48) which you are going to programme. Reference • 1.3 System Features (F/G) – Trunk Group Parameter Type Default Public Value Range Public Private VPN (Virtual Private Network) Description/Function Specifies the network type for the trunk group.
  • Page 126 Group Parameter Intercept Destination – Day / Night Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the destination extension (3 or 4 digits) for Intercept Routing feature in both Day and Night modes respectively. Notes • Intercept Routing provides an automatic re-direction of calls that have not been answered.
  • Page 127 Group Parameter Line Hunting Order Default Normal Value Range Normal Reverse Sequential Description/Function Specifies the hunting sequence of idle lines on a trunk group basis. Normal: The system connects the user to an idle trunk line with the lowest physical number. Reverse: The system connects the user to an idle trunk line with the highest physical number.
  • Page 128 Group Parameter Flash Time Default 80 ms: [SA], 600 ms: Others Value Range None 80 ms 300 ms 600 ms 900 ms 1200 ms Description/Function Specifies the length of flash time. Notes • When you need finer resolution, assign this to 80 ms and use "Flash Time"...
  • Page 129 Group Parameter Pause Time Default 1.5 s Value Range 1.5 s 2.5 s 3.5 s 4.5 s Description/Function Specifies the length of pause time (dialling delay). The programmed pause time is automatically inserted after a line access code or a host PBX access code, or manually inserted when the PAUSE button is pressed by the extension user.
  • Page 130 Group Parameter [Numbering Plan ID] Outgoing—Private Default Private Value Range Default Unknown ISDN / Telephony National Standard Private Description/Function Specifies the Numbering Plan ID applied to the outgoing CO calls via ISDN Private Network. Reference • 3.2 VPN Features (F/G) –...
  • Page 131 Group Parameter PBX Dial Tone Default Disable Value Range Enable Disable Description/Function If enabled, the system sends a dial tone to the extension user who seizes an E&M / E1 / T1 digital trunk line. (Available for E&M / E1 / T1 digital trunk lines only.) Note •...
  • Page 132 Group Parameter [Type of Number] Outgoing—Public Default Default Value Range Default Unknown International National Network Specific Subscriber Description/Function Specifies the Type of Number applied to the outgoing CO calls via ISDN Public Switched Telephone Network. Reference • 3.2 VPN Features (F/G) –...
  • Page 133 Group Parameter [Type of Number] Incoming—Private Default Default Value Range Default Unknown International National Network Specific Subscriber Description/Function Specifies the Type of Number applied to the incoming CO calls via ISDN Private Network. Reference • 3.2 VPN Features (F/G) – Virtual Private Network (VPN) Parameter Cyclic Signal Detection Default...
  • Page 134 Group Parameter Silence Detection Default Check Value Range No check [Disable] Check [Enable] Description/Function Used to disconnect the trunk line when the system detects no signal during a CO-to-CO line call by DISA or AGC. Reference • 1.5 Attended Features (F/G) –...
  • Page 135 Group Parameter ISDN Progress Tone Mode Default Automatic Value Range Automatic Network Description/Function Selects the way to supply the progress tone to an extension when the extension user makes an outgoing call via ISDN. Automatic: If the network provides a progress tone, the system sends the network progress tone to the caller.
  • Page 136: Extension Group

    Group 3.3 Extension Group Used to assign various parameters for up to 128 (1-128) Extension Groups. Which parameters apply to your Extension Group? Please refer to the table on the Page 137 and Page 138. Note • By default, the Group Type of Group No.126 is VM, No.127 is AA and No.128 is Operator.
  • Page 137 Group Applicability of Parameters to Group Types Group Type Parameter None Ter. Cir. Ring Ope. Group No. Tenant No. [Overflow Setting] Destination – Day / Night [Overflow Setting] Timer FWD / DND Mode Extension Call Hunting Calls to Empty Group [Operator Setting] Ringing Type [Operator Setting]...
  • Page 138 Group Applicability of Group Types to Overflow Destinations Overflow Destination Group External Extension Phantom Incoming Type Pager Group Group Extension Group None Terminate Circular Operator ( = assignable) When "DIL 1:N" is specified in "Group Type" programming of Incoming Group, this feature does not work.
  • Page 139 Group Extension Group Copy Used to copy a part of or all settings of a certain Extension Group to all other Extension Groups at a time. You can also specify one or several Extension Groups as the copy destination. Copying the Extension Group Parameters to Other Extension Groups 1.
  • Page 140 Group • Parameters of the destination Extension Groups are immediately effective when copying is finished. Parameter Group No. Default Value Range 1-128 Description/Function Specifies the Extension Group (1-128) which you are going to programme. Reference •1.3 System Features (F/G) – Extension Group Parameter Copy Default...
  • Page 141 Group Parameter Tenant No. Default Value Range Description/Function Specifies the tenant (1-8) to which the Extension Group is assigned. (Required when "Tenant Service" is employed.) Reference •1.3 System Features (F/G) – Tenant Service • 2.2 Tenant (P/G) Parameter [Overflow Setting] Destination – Day / Night Default Blank Value Range...
  • Page 142 Group Parameter Group Type Default Group No.126: VM, Group No.127: AA, Group No.128: Operator, Others: None Value Range None Terminate Circular Ring Operator Description/Function Specifies the Group Type for each Extension Group. This determines how the Extension Group handles the incoming calls directed to it.
  • Page 143 Group Parameter FWD / DND Mode Default Enable Value Range Disable Enable Description/Function Specifies whether to enable or disable the FWD / DND (Call Forwarding or Do Not Disturb) feature assigned on all extensions in the Extension Group. (Assignable only when "Terminate," "Ring," "Circular" or "UCD" is specified in "Group Type"...
  • Page 144 Group Parameter Calls to Empty Group Default Disable Value Range Enable Disable Description/Function Allows for calls to empty (all Logout) Operator or UCD Groups to be queued. If enabled, calls will be queued to the group. If disabled, the extension will receive a reorder tone, and the CO call will be transferred to the overflow destination immediately.
  • Page 145 Group Parameter [UCD Setting] FWD No Answer Default Disable Value Range Disable Enable Description/Function Specifies the treatment of the call which is not answered by the extension in the UCD group within a specified period of time (Call Forwarding - No Answer Time). Disable: The call continues to ring the current destination extension.
  • Page 146 Group Parameter [UCD Setting] Supervisor Extension Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the Supervisor Extension per UCD Group. The extension specified as the Supervisor Extension can monitor the number of waiting calls (calls placed in the waiting queue). Reference •...
  • Page 147 Group Parameter [UCD Setting] UCD Call Waiting Default Enable Value Range Disable Enable Description/Function This feature is different from regular Call Waiting. This feature (if enabled) allows UCD group members to hear a Call Waiting tone when an inside / outside call arrives but all the extensions in the UCD Group are busy.
  • Page 148 Group Parameter [Operator Setting] Ringing Type Default Single Value Range Multi Single Description/Function Specifies whether the calls coming in on an Operator Group ring one Operator (Single) or all Operators in the group (Multi) simultaneously. (Assignable only when "Operator" is specified in "Group Type" programming.) Reference •1.3 System Features (F/G)
  • Page 149: Paging Group

    Group 3.4 Paging Group Used to programme up to 16 Paging Groups. Each Paging Group consists of up to 24 Extension Groups. One Extension Group can be assigned to only one Paging Group. Parameter Paging Group No. Default Value Range 1-16 Description/Function Specifies the Paging Group (1-16) which you are going to...
  • Page 150: Incoming Group

    Group 3.5 Incoming Group Used to programme a list of up to 96 Incoming Groups. Which parameters apply to your Incoming Group? Please refer to the table on Page 151 and Page 152. Programming Guide...
  • Page 151 Group Applicability of Parameters to Group Types Group Type Parameter DIL 1:N Ter. Ring Ope. [Overflow Setting] Destination — Day / Night [Overflow Setting] Timer FWD / DND Mode Search Mode Calls to Empty Group [Operator Setting] Ringing Type [Operator Setting] Call Priority [UCD Setting] Time Table No.
  • Page 152 Group Applicability of Group Types to Overflow Destinations Overflow Destination Group External Extension Phantom Incoming Type Pager Group Group Extension Group Terminate Operator ( = assignable) When "DIL 1:N" is specified in "Group Type" programming of Incoming Group, this feature does not work.
  • Page 153 Group 3. Select the Incoming Group parameters to copy in "Copy Item" field. • Only parameters which are available to copy are shown in "Copy Item" field. This depends on the Group Type assignment of the copy source Incoming Group. •...
  • Page 154 Group Parameter Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the FDN (Floating Directory Number) for the Incoming Group. Reference • 1.3 System Features (F/G) – Floating Station Parameter DN Refer Default — Value Range — Description/Function Displays the list of DNs/FDNs which are already assigned to the extensions / system resources.
  • Page 155 Group Parameter [Overflow Setting] Destination – Day / Night Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the destination extension where the call is transferred to when all extensions in the Incoming Group are unavailable or logged-out in Day / Night mode respectively. (Assignable only when "Terminate,"...
  • Page 156 Group Parameter FWD / DND Mode Default Enable Value Range Disable Enable Description/Function Specifies whether to enable or disable the FWD / DND (Call Forwarding or Do Not Disturb) feature assigned on all extensions in the Incoming Group. (Assignable only when "Terminate," "Ring" or "UCD" is specified in "Group Type"...
  • Page 157 Group Parameter Calls to Empty Group Default Disable Value Range Enable Disable Description/Function Allows for calls to empty (all Logout) Operator or UCD Groups to be queued. If enabled, calls will be queued to the group. If disabled, the extension will receive a reorder tone, and the CO call will be transferred to the overflow destination immediately.
  • Page 158 Group Parameter [UCD Setting] FWD No Answer Default Disable Value Range Disable Enable Description/Function Specifies the treatment of the call which is not answered by the extension in the UCD group within a specified period of time (Call Forwarding - No Answer Time). Disable: The call continues to ring the current destination extension.
  • Page 159 Group Parameter [UCD Setting] Supervisor Extension Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the Supervisor Extension per UCD Group. The extension specified as the Supervisor Extension can monitor the number of waiting calls (calls placed in the waiting queue) and the Login/Logout status of UCD Group members through the corresponding DSS buttons.
  • Page 160 Group Parameter [Operator Setting] Call Priority Default CO Call:1, Intercept Routing:2, Recall:3, Extension Call:4 Value Range Priority 1-4 Description/Function Specifies the answering priority of incoming calls to the Operator Group by a type of call when more than one call is ringing at an Operator extension.
  • Page 161 Group 3.5.1 Destination for Incoming Group You can assign up to 72 extensions and/or Extension Groups per Incoming Group so that an incoming CO call rings multiple extensions simultaneously. Parameter [Destinations] DN Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies extensions and/or Extension Groups that you are going to assign to the specified Incoming Group.
  • Page 162 Group Parameter [Destinations] Ringing Type Default Immediate Value Range Immediate 1-ring Delay 3-ring Delay 6-ring Delay No Ring Description/Function Specifies the ringing delay of the calls arriving at extensions whose "Group Type" programming is specified as "DIL 1:N." Immediate: An extension rings immediately. 1-ring Delay: An extension rings in 1-ring delay timing.
  • Page 163: Ogm Group

    Group 3.6 OGM Group Used to assign parameters for OGM Groups (1-8). OGM resources on the DISA card can be grouped together as an OGM Group. Parameter Group No. Default Value Range Description/Function Specifies the OGM Group (1-8) which you are going to programme.
  • Page 164 Group Parameter DN Refer Default — Value Range — Description/Function Displays the list of DNs/FDNs which are already assigned to the extensions / system resources. Reference None Parameter Tenant No. Default Value Range Description/Function Specifies the tenant (1-8) to which you are going to assign this OGM Group.
  • Page 165 Group Parameter Security Mode Default Trunk Value Range None Trunk Description/Function Specifies the Security Mode for DISA callers. (Assignable only when "DISA" is specified in "OGM Type" programming.) None (Non security mode): DISA callers can make both outside and intercom calls via DISA without restriction.
  • Page 166 Group Programming Guide...
  • Page 167: Line

    Line Section 4 Line Programming Guide...
  • Page 168 Line 4.1 Line Used to assign various parameters for both trunk and extension lines. Programming Guide...
  • Page 169: Trunk Line

    Line 4.2 Trunk Line Used to assign various parameters for trunk lines. Programming Guide...
  • Page 170 Line Trunk Line Copy Used to copy a part of or all settings of a certain Trunk Line to all other same type Trunk Lines at a time. You can also specify one or several Trunk Lines as the copy destination. This copy function is available between the Trunk Lines of the same type Trunk Cards.
  • Page 171 Line • Parameters of the destination Trunk Lines are immediately effective when copying is finished. Parameter Card No. Default — Value Range XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the physical number of the trunk card and its type, which you are going to programme.
  • Page 172 Line Parameter Name Default CO001-CO192 Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function Specifies the name for the trunk line. Note •...
  • Page 173 Line Parameter Incoming Type Description/Function <Available selections and the default values per Card Type> Card Type Selection Default TIE/DDI/MSN DID, DID-2W DID-MFC DID/TIE DIL/DID/TIE Refer to the (Refer to the table below.) table below. E&M, T1(TIE) DIL/TIE T1(DID) DIL/DID LCOT, GCOT, RCOT, PCOT, ELCOT, T1(LCO),...
  • Page 174 Line Parameter Dial Type Default Pulse-10: [SA], DTMF-80: Others (DID-2W/E1/E&M/ELCOT/ GCOT/LCOT/PCOT/RCOT/T1 card), ISDN (BRI/PRI23/PRI30 card), MFC-R2 (DID-MFC card) Value Range Pulse-10 (10 PPS) Pulse-20 (20 PPS) DTMF-80 (80 ms) DTMF-160 (160 ms) MFC-R2 ISDN Description/Function Specifies the dial type for each trunk line. This is the dial type regardless of the dial mode of the extension telephone.
  • Page 175 Line Parameter Destination – Day / Night / Lunch / Break Default Day, Night: 1001, Lunch, Break: Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the destination for the trunk line whose "Incoming Type" is set to "DIL." The following numbers can be assigned as the destination: Extension numbers, FDNs.
  • Page 176 Line Parameter [DDI / DID / TIE] Digits to delete Default Value Range 0-16 digits Description/Function Specifies the number of digits to be deleted from the number received from the DDI / DID trunk / other PBX via TIE lines. Reference •...
  • Page 177 Line Parameter Collect Call Default Enable Value Range Enable Disable Description/Function Specifies whether to enable or disable receiving the collect calls via this trunk line. (Assignable only when E1 [DR2] / ELCOT / LCOT / RCOT / PCOT / DID / DID-2W / DID-MFC card is installed in the system.) Reference None Parameter...
  • Page 178 Line Parameter Start Signal Type Default Wink Value Range Immediate Wink Description/Function Specifies the start signal type for a DID trunk and a TIE (E&M) trunk. Immediate: The system sends the dialling digits to CO after waiting for the time length determined by "First Dial Timer" in "Card Properties"...
  • Page 179 Line Parameter [CPC Signal] OUT Detection Default Enable: DID / DID-2W / DID-MFC / E1 [DR2] card, Disable: ELCOT / GCOT / LCOT / PCOT / RCOT / T1 [GCO] / T1 [LCO] card Value Range Enable Disable Description/Function Specifies whether CPC Detection on outgoing CO calls is enabled or disabled.
  • Page 180 Line Parameter [CPC Signal] IN Detection Default [NZ]: Enable, Others (Enable: DID / DID-2W / DID-MFC / E1 [DR2] card, Disable: ELCOT / GCOT / LCOT / PCOT / RCOT / T1 [GCO] / T1 [LCO] card) Value Range Enable Disable Description/Function Specifies whether CPC Detection on incoming CO calls is enabled...
  • Page 181 Line Parameter [TIE Line] Type Default 4 wires Value Range 2 wires 4 wires Description/Function Specifies the voice path type of TIE Lines. Reference • 3.1 TIE Line Features (F/G) – TIE Line Service Parameter [TIE Line] Sensitivity - IN EXT Default 0 dB Value Range...
  • Page 182 Line Parameter [TIE Line] Sensitivity - OUT CO Default 0 dB Value Range - 3 to +6 dB in 3 dB increments Description/Function Specifies the voice level for transmission. Reference • 3.1 TIE Line Features (F/G) – TIE Line Service Parameter [TIE Line] Sending TIE Caller ID Default...
  • Page 183 Line Parameter Reverse Signal Detection Default Enable: [NZ], Disable: Others Value Range Enable Disable Description/Function If an ELCOT / RCOT card is installed in the system, reversal of CO line polarity is monitored at each port by default. Specifies whether to enable or disable this monitoring function.
  • Page 184: Extension Line

    Line 4.3 Extension Line 4.3.1 Extension Line 1/2 Used to assign parameters for extension lines. Programming Guide...
  • Page 185 Line Extension Line Copy Used to copy a part of or all settings of a certain Extension Line to all other Extension Lines at a time. You can also specify one or several Extension Lines as the copy destination. Copying the Extension Line Parameters to Other Extension Lines 1.
  • Page 186 Line Parameter Card No. Default — Value Range XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the physical number of the extension card and its type, which you are going to programme. Reference • 1.2 Slot Assignment (P/G) Parameter Port No.
  • Page 187 Line Parameter Copy Default — Value Range — Description/Function You can enter into "Extension Line Copy" screen by clicking this button. Reference — Parameter Name Default Blank Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ;...
  • Page 188 Line Parameter Mailbox No. Default Same as the extension number Value Range Up to 16 digits consisting of 0 - 9, , # or P [Pause] Description/Function Specifies the mailbox number which is usually the same as the extension number. Note •...
  • Page 189 Line Parameter Charge Limit Default Value Range 0: No limit 1-99999: The number of charge metre allowable for the extension Description/Function Used to determine the sum total of telephone charge allowable to extension users on an extension basis. If the telephone charge on the extension exceeds the limit, a toll call cannot be made anymore from that extension.
  • Page 190 Line Parameter [Preferred Line] Outgoing Default Prime Line - ICM/PDN Value Range No Line Idle Line Prime Line - ICM / PDN Prime Line - CO Description/Function Specifies the line to which the extension is connected automatically when the extension user goes off-hook to make a call. Reference •...
  • Page 191 Line Parameter [Preferred Line] Incoming - Key No. Default Blank Value Range 1-24 Description/Function Specifies the CO button to which the extension is connected when the extension user goes off-hook to answer a call. This assignment is required when "Prime Line - CO" is specified in "[Preferred Line] Incoming"...
  • Page 192 Line Parameter [LCS Setting] Status Default Inactive Value Range Inactive Active Description/Function Specifies whether or not the extension can use the LCS (Live Call Screening) feature. Reference • 1.9 Answering Features (F/G) – Live Call Screening (LCS) Parameter [LCS Setting] Operation Mode Default Hands-free Value Range...
  • Page 193 Line Parameter Data Line Mode Default Value Range Description/Function Assigns whether "Data Line Security mode" is available or not. If set to "No," setting "Data Line Security mode" by dialling the feature number is impossible. Reference • 1.12 Conversation Features (F/G) –...
  • Page 194 Value Range English Option Description/Function Specifies the language shown on a PANASONIC display PT. The language is set for each extension, so phones on the same system can display different languages. Notes • French is stored as default Optional Language at the factory.
  • Page 195 Line Parameter ISDN Bearer Mode Default Automatic Value Range Automatic Speech 3.1 KHz Audio Description/Function Specifies the ISDN Bearer Mode on an extension basis. Note • When "Automatic" (Default) is selected, Bearer Mode is set automatically depending on the type of extension telephone as follows: PT - Speech, SLT - 3.1 KHz Audio, ISDN extension - depending on the bearer mode of the ISDN extension.
  • Page 196 / outgoing calls via Public Switched Telephone Network to each extension. Notes • The KX-TD500 System is designed and manufactured in accordance with the following ETS (European Telecommunication Standard) specifications: ETS 300 122 Generic Keypad protocol for the support of supplementary services.
  • Page 197 / outgoing calls via Private Network to each extension. Notes • The KX-TD500 System is designed and manufactured in accordance with the following ETS (European Telecommunication Standard) specifications: ETS 300 122 Generic Keypad protocol for the support of supplementary services.
  • Page 198 Line Parameter [Call Log Incoming] Lock Password Default Blank Value Range Fixed to 3 digits consisting of 0-9 Description/Function Specifies the Call Log Incoming, Log Lock password. The extension user can lock the call log display so that incoming call information is not shown on the display. Note •...
  • Page 199 Line <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Key Type Display" button (including "Not Stored") for each CO key on the above screen. <Additional Parameters Required by Key Type> Depending on a Key Type, additional parameters are required as follows. Additional Key Type Parameters...
  • Page 200 Line Additional Key Type Parameters Description (default) Tone (2) Specifies the ringer frequency (ring tone type: 1 - 8) for incoming calls. Ringing Type Specifies the timing of ringing when a call comes in on the (Immediate) extension: Immediate, 1-ring Delay, 3-ring Delay, 6-ring Delay, No Ring EXT.
  • Page 201 Originating Features" in the Features Guide). This service may not work properly, if your ISDN Service carrier does not support this service. • The KX-TD500 System is designed and manufactured in accordance with the following ETS (European Telecommunication Standard) specifications: ETS 300 122 Generic Keypad protocol for the support of supplementary services.
  • Page 202 Line 4.3.3 Flexible PF Key Assignment for PT Used to determine the usage of flexible PF buttons on PTs. The following screen is displayed by clicking on "4-2 Extension Line" screen. <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Key Type Display" button (including "Not Stored") for each PF Key on the above screen.
  • Page 203 Line <Additional Parameters Required by Key Type> Depending on a Key Type, additional parameters are required as follows. Additional Key Type Description Parameters ONE-TOUCH Dial Specifies the telephone number or feature access number (up to 24 digits consisting of 0 - 9, , #, -, P, S or F). Note •...
  • Page 204 Line 4.3.4 Extension Line 2/2 Used to assign parameters for extension lines. Parameter Intercept Destination – Day / Night Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the destination extension (3 or 4 digits) for Intercept Routing feature in both Day and Night modes respectively. Notes •...
  • Page 205 Line Parameter Call Forwarding-No Answer Time Default 0 ring Value Range 0-12 rings Description/Function Specifies the number of rings before the Call Forwarding No Answer feature is activated. If a call is not answered before the programmed number of rings, the call is redirected to the pre-assigned extension.
  • Page 206: Dss Console

    Line 4.4 DSS Console Used to assign the paired extension for a DSS (Direct Station Selection) Console and the usage of DSS and PF buttons. Programming Guide...
  • Page 207 Line DSS Console Copy Used to copy a part of or all settings of a certain DSS Console to all other DSS Consoles at a time. You can also specify one or several DSS Consoles as the copy destination. Copying the DSS Console Parameters to Other DSS Consoles 1.
  • Page 208 Line Notes • Flexible DSS / PF Key Assignment should be done before executing this copy function. • Copy function is not available in the Interactive mode. Parameter Paired Extension Default (Display only) Value Range 3-4 digits consisting of 0-9 Description/Function Displays the extension paired with the DSS console.
  • Page 209 Line Parameter PF Key Default — Value Range — Description/Function You can enter into "Flexible PF Key" screen (Section 4.4.2) by clicking on this screen. Reference • 4.1.2 Customising the Buttons (U/M) Parameter Copy Default — Value Range — Description/Function You can enter into "DSS Console Copy"...
  • Page 210 Line <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Key Type Display" button (including "Not Stored") for each DSS Key on the above screen. <Additional Parameters Required by Key Type> Depending on a Key Type, additional parameters are required as follows. Additional Key Type Description...
  • Page 211 Line Additional Key Type Description Parameters Dial Specifies the telephone number or feature access number (up to 24 digits consisting of 0-9, , #, -, P, S or F). Note • P: Pause, S: Secret Dialling, F: Hook Flash Parameter Key Type Default Not Stored...
  • Page 212 Line 4.4.2 Flexible PF Key Assignment for DSS Console Used to determine the usage of flexible PF buttons on DSS Consoles. The following screen is displayed by clicking on "4-3 DSS Console" screen. <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Key Type Display" button (including "Not Stored") for each PF Key on the above screen.
  • Page 213 Line <Additional Parameters Required by Key Type> Depending on a Key Type, additional parameters are required as follows. Additional Key Type Description Parameters ONE-TOUCH Dial Specifies the telephone number or feature access number (up to 24 digits consisting of 0 - 9, , #, -, P, S or F). Note •...
  • Page 214: Doorphone

    Line 4.5 Doorphone Used to assign the destination extensions for incoming calls from doorphones. Note • The DPH/DPHG card is not available in some countries/areas. Parameter Card No. Default — Value Range XXX : DPH/DPHG [XXX : Card No. (101-314)] Description/Function Specifies the physical number of a doorphone card which you are going to programme.
  • Page 215 Line Parameter Tenant No. Default Value Range 1 - 8 Description/Function Specifies the tenant (1-8) to which the doorphone port is assigned. Reference • 1.3 System Features (F/G) – Tenant Service • 1.12 Conversation Features (F/G) – Doorphone Call • 2.2 Tenant (P/G) Parameter Destination –...
  • Page 216: External Paging

    Line 4.6 External Paging Used to assign parameters for External Paging. Parameter Pager No. Default (Display only) Value Range 1, 2 Description/Function Displays the Pager No. Reference • 2.8.2 External Pager (Paging Equipment) (I/M) Parameter Tenant No. Default Value Range Description/Function Specifies the tenant to which the External Pager is assigned.
  • Page 217 Line Parameter Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the FDN (Floating Directory Number) for the External Pager. Reference • 1.3 System Features (F/G) – Floating Station Parameter Default No check Value Range No check [Disable] Check [Enable] Description/Function Specifies whether BGM is sent or not when the External Pager is...
  • Page 218 Line Parameter DN Refer Default — Value Range — Description/Function Displays the list of DNs/FDNs which are already assigned to the extensions / system resources. Reference None Programming Guide...
  • Page 219: Isdn Extension Line

    Line 4.7 ISDN Extension Line Used to assign parameters for ISDN extension lines. Parameter Card No. Default — Value Range XXX: BRI [XXX: Card No. (101-314)] Description/Function Specifies the physical number of the BRI card which you are going to programme. Reference •1.2 Slot Assignment (P/G) Parameter...
  • Page 220 Line Parameter Group No. Default (Display only) Value Range 1-128 Description/Function Displays the Extension Group to which the selected ISDN extension port is assigned. Reference • 1.9 BRI Port Assignment (P/G) Parameter Name Default Blank Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ;...
  • Page 221 Line Parameter ISDN Bearer Mode Default Automatic Value Range Automatic Speech 3.1 KHz Audio Description/Function Specifies the ISDN Bearer Mode on an ISDN extension basis. Note • When "Automatic" (Default) is selected, Bearer Mode is set automatically depending on the type of extension telephone as follows: PT –...
  • Page 222 / outgoing calls via Public Switched Telephone Network to each ISDN extension. Notes • The KX-TD500 System is designed and manufactured in accordance with the following ETS (European Telecommunication Standard) specifications: ETS 300 122 Generic Keypad protocol for the support of supplementary services.
  • Page 223 / outgoing calls via Private Network to each ISDN extension. Notes • The KX-TD500 System is designed and manufactured in accordance with the following ETS (European Telecommunication Standard) specifications: ETS 300 122 Generic Keypad protocol for the support of supplementary services.
  • Page 224 Line Parameter [COS No.] Secondary Default Value Range 1-96 Description/Function Specifies the Secondary COS (Class of Service) (1-96) to the ISDN extension. Reference • 1.3 System Features (F/G) – Class of Service (COS) – Hotel Application • 3.1.5 Changing Service Level of Extensions (Switching COS) (U/ •...
  • Page 225: Pc Console Line

    Line 4.8 PC Console Line 4.8.1 PC Console Line 1/2 Used to assign parameters for PC Console lines. Parameter Card No. Default — Value Range XXX:YYY [XXX: Card No. (101-314), YYY: Card Type] Description/Function Specifies the physical number of the extension card and its type (DLC or DHLC).
  • Page 226 Line Parameter Default — Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the PC Console which you are going to programme. Reference •1.4 Extension Port Assignment (P/G) •2.3 Numbering Plan (P/G) Parameter Group No. Default (Display only) Value Range 1-128 Description/Function Displays the Extension Group to which the selected extension port...
  • Page 227 VTR (Voice Mail Transfer) button is used to transfer the call to the Panasonic VPS (Voice Processing System) so that the caller can leave his message in the mailbox of the desired extension. Reference • 2.8.3 If a Voice Processing System is Connected (U/M)
  • Page 228 Line Parameter [VM Key] 2WAY-TRN Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the Directory Number of the Voice Mail extension. "VM Key" screen is displayed by clicking on this screen. 2WAY-TRN( Two-Way Transfer) button is used to record a conversation into the mailbox of another extension.
  • Page 229 Line Parameter [COS No.] Primary Default Value Range 1-96 Description/Function Specifies the Primary COS (Class of Service) to the PC Console. Reference • 1.3 System Features (F/G) – Class of Service (COS) – Hotel Application • 3.1.5 Changing Service Level of Extensions (Switching COS) (U/M) •...
  • Page 230 Line Parameter [Preferred Line] Outgoing – Key No. Default Blank Value Range 1-24 Description/Function Specifies the CO button to which the PC Console is connected when the PC Console user goes off-hook to make a call. This assignment is required when "Prime Line – CO" is specified in "[Preferred Line] Outgoing"...
  • Page 231 Line Parameter [Pickup Dialing] Mode Default Disable Value Range Enable Disable Description/Function Specifies whether "Pickup Dialling" feature is enabled or not. Reference • 1.7 Dialling Features (F/G) – Pickup Dialling (Hot Line) • 2.2.2 Easy Dialling (U/M) Parameter [Pickup Dialing] Dial Default (Display only) Value Range...
  • Page 232 Line Parameter [LCS Setting] Operation Mode Default Hands-free Value Range Private Hands-free Description/Function Assigns whether the voice message being recorded is monitored automatically through the built-in speaker (Hands-free mode) or an alert tone is sent (Private mode) while an incoming caller is leaving a message in the mailbox of the PC Console.
  • Page 233 Line Parameter Data Line Mode Default Value Range Description/Function Assigns whether "Data Line Security mode" is available or not. If set to "No," setting "Data Line Security mode" by dialling the feature number is impossible. Reference • 1.12 Conversation Features (F/G) –...
  • Page 234 Value Range English Option Description/Function Specifies the language shown on a PANASONIC display PT. The language is set for each extension, so phones on the same system can display different languages. Note • French is stored as default Optional Language at the factory.
  • Page 235 Line Parameter ISDN Bearer Mode Default Automatic Value Range Automatic Speech 3.1 KHz Audio Description/Function Specifies the ISDN Bearer Mode on a PC Console basis. Note • When "Automatic" (Default) is selected, Bearer Mode is set automatically depending on the type of extension telephone as follows: PT –...
  • Page 236 / outgoing calls via Public Switched Telephone Network to each PC Console. Notes • The KX-TD500 System is designed and manufactured in accordance with the following ETS (European Telecommunication Standard) specifications: ETS 300 122 Generic Keyboard protocol for the support of supplementary services.
  • Page 237 / outgoing calls via Private Network to each PC Console. Notes • The KX-TD500 System is designed and manufactured in accordance with the following ETS (European Telecommunication Standard) specifications: ETS 300 122 Generic Keyboard protocol for the support of supplementary services.
  • Page 238 Line Parameter [Call Log Incoming] Lock Password Default Blank Value Range Fixed to 3 digits consisting of 0-9 Description/Function Specifies the Call Log Incoming, Log Lock password. The PC Console user can lock the call log display so that incoming call information is not shown on the PC Console.
  • Page 239 Line Parameter Intercept Destination – Day / Night Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the destination extension (3 or 4 digits) for Intercept Routing feature in both Day and Night modes respectively. Notes • Intercept Routing provides an automatic re-direction of calls that have not been answered.
  • Page 240 Line Programming Guide...
  • Page 241: Features

    Features Section 5 Features Programming Guide...
  • Page 242 Features 5.1 Features Used to assign parameters for various system features. Programming Guide...
  • Page 243: System Speed Dialling

    Features 5.2 System Speed Dialling Used to programme a list of up to 1000 (000-999) frequently dialled numbers per tenant. Anyone in the same tenant can dial these numbers. Up to 2000 Speed Dialling codes can be shared among tenants under the limitation of 1000 codes per tenant.
  • Page 244 Features Parameter Entry No. Default 000-019 Value Range 000-999 in 20 codes increments Description/Function Specifies the entry number of the Speed Dialling codes which you are going to programme. Reference None Parameter Max. Entry Default (Display only) Value Range 0-1000 Description/Function Displays the maximum number of Speed Dialling codes allocated to the tenant.
  • Page 245 Features Parameter Name Default Blank Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function Specifies the name for each speed dial code. Notes •...
  • Page 246: Phantom Extension

    Features 5.3 Phantom Extension Used to register up to 448 Phantom Extension numbers. Parameter Entry No. Default 001-048 Value Range 001-448 in 48 codes increments Description/Function Specifies the entry number of phantom extension number which you are going to programme. Reference •...
  • Page 247 Features Parameter DN Refer Default — Value Range — Description/Function Displays the list of DNs/FDNs which are already assigned to the extensions / system resources. Reference None Programming Guide...
  • Page 248: Emergency Dial Code

    Features 5.4 Emergency Dial Code Used to programme a list of up to 10 emergency numbers that any extension in the system can dial at any time, regardless of dialling restrictions. Parameter Dial Default All: Blank Value Range Up to 24 digits consisting of 0-9 Description/Function Specifies emergency telephone numbers that can be dialled from any extension regardless of restrictions imposed by "Toll...
  • Page 249: Quick Dialling

    Features 5.5 Quick Dialling Used to store up to eight Quick Dialling numbers. Parameter Dial Default All: Blank Value Range Up to 24 digits consisting of 0-9, , #, F, P, S or "-" (hyphen) Description/Function Specifies the phone number for Quick Dialling. Note •...
  • Page 250: Account Code

    Features 5.6 Account Code Used to programme a list of up to 1000 account codes which are used to identify incoming and outgoing CO calls for accounting and billing purposes. Parameter Tenant No. Default Value Range Description/Function Specifies the tenant to which a list of Account Codes is assigned. (Required when "Tenant Service"...
  • Page 251 Features Parameter Code Default Blank Value Range Up to 10 digits consisting of 0-9 Description/Function Specifies the account codes. Reference • 1.3 System Features (F/G) – Account Code Entry • 2.2.5 Calling without Restrictions (U/M) Parameter TRS Level Default None Value Range None, 1-6 Description/Function...
  • Page 252: Special Carrier Code

    Features 5.7 Special Carrier Code Used to programme a list of up to 100 Special Carrier Codes. Parameter Code Default Blank Value Range Up to 10 digits consisting of 0-9, , # or X Description/Function Specifies special carrier access codes. Notes •...
  • Page 253: Waiting Second Dial Tone Code

    Features 5.8 Waiting Second Dial Tone Code Used to assign parameters for the Waiting Second Dial Tone feature. Parameter Entry No. Default 001-020 Value Range 001-200 in 20 codes increments Description/Function Specifies the entry number of the Waiting Second Dial Tone codes which you are going to programme.
  • Page 254 Features Parameter Mode Default Disable Value Range Enable Disable Description/Function Specifies whether Waiting Second Dial Tone mode is enabled or not. Note • In some areas, upon completion of area code entry, the extension user must ensure the reception of the second dial tone from the Central Office before dialling the office code and the subscriber number.
  • Page 255: Absent Message

    Features 5.9 Absent Message Used to programme a list of up to nine absent messages. An absent message, if set by the extension user, is displayed on the calling extension's display PT to show the reason of absence (no answer). Programming Guide...
  • Page 256 Features Parameter Message Default MSG1: Will Return Soon, MSG2: Gone Home, MSG3: At Ext %%%% (Extension No.), MSG4: Back at %% : %% (Hour: Minute), MSG5: Out Until %% / %% (Month / Day), MSG6: In a Meeting, MSG7-9: Blank Value Range Up to 16 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ %...
  • Page 257: Disa/Tie User Code

    Features 5.10 DISA/TIE User Code Used to programme a list of up to 32 DISA/TIE User Codes. Each code is appended with a COS level. Programming Guide...
  • Page 258 Features Parameter Code Default All: Blank Value Range 4-10 digits consisting of 0-9 Description/Function Specifies the User Codes for DISA/TIE feature. Warning for the Direct Inward System Access Users When you enable the CO-to-CO Line Call feature of Direct Inward System Access (DISA) function, if a third party discovers the password (a DISA User Code) of the system, you have a risk that they will make illegal phone calls using your telephone line, and the cost may be charged to your account.
  • Page 259: Vps Integration

    Used to assign Integration Code and Voice Mail Command for VPS Integration. Integration Code When DTMF tone Integration is activated, the KX-TD500 informs the VPS (Voice Processing System) of the status of the call (busy, answered, ringing, etc.) by sending a code with DTMF tone before sending the normal call progress tone (busy tone, ringback tone, etc.).
  • Page 260 Features Parameter [Integration Code] Busy Tone Default Value Range Up to 3 digits consisting of 0-9, or # Description/Function Specifies the Busy Tone code. Sent to the Voice Mail port when the extension dialled is busy. Reference • 1.3 System Features (F/G) –...
  • Page 261 Features Parameter [Integration Code] Extension Disconnection Default Value Range Up to 3 digits consisting of 0-9, or # Description/Function Specifies the Extension Disconnection code. Sent to the Voice Mail port when the caller disconnects. The Central Office must set a CPC signal to the PBX line for this signal to work for CO calls.
  • Page 262 Features Parameter [Integration Code] FWD to VM Busy Tone Default Value Range Up to 3 digits consisting of 0-9, or # Description/Function Specifies the FWD to VM Busy Tone code. Sent to the Voice Mail port when the extension dialled is forwarded to Voice Mail and no other Voice Mail ports are available to accept the call.
  • Page 263 Features Parameter [Voice Mail Command] Get Message Default Value Range Up to 16 digits consisting of 0-9, , # or H Description/Function Specifies the Get Message command. This command is transmitted to a VM port when the message receiver presses the MESSAGE button to retrieve a voice message. Reference •...
  • Page 264 Features 5.11.2 VPS Integration 2/2 Used to assign optional parameters for VPS Integration. Parameter DTMF signal duration Default 80 ms Value Range 80 ms 160 ms Description/Function Specifies the duration of the DTMF signals sent to the Voice Mail ports. Reference •...
  • Page 265 Features Parameter Pause timing before sending DTMF signal (RBT, BT) Default 1.5 s Value Range 0.5 s 1.0 s 1.5 s 2.0 s Description/Function Specifies the length of time in seconds the system is to wait before sending Integration Code with DTMF signals (System- Voice Mail, Extension Status).
  • Page 266 Features Parameter Extension's mailbox number Default Programmed number Value Range Extension number Programmed number Description/Function Specifies whether an extension's mailbox number is substituted by the extension number or it is programmable (free). If a call is forwarded or rerouted to the Voice Mail port, the system automatically transmits the mailbox number to the Voice Mail port to specify the extension user's mailbox.
  • Page 267 Features Parameter Sending out Follow-on ID after IRNA Default Disable Value Range Disable Enable Description/Function Specifies whether or not the system sends Follow-on ID to a Voice Mail port after redirecting a call (IRNA) to the Voice Mail port. Reference •...
  • Page 268: Caller Id Modification

    [Local Call] Area Code Default Blank Value Range Up to 6 digits consisting of 0-9 Description/Function Specifies the area code of the location where your KX-TD500 system is installed. Note • This local area code is referenced to modify the telephone number. Reference •...
  • Page 269 Features Parameter [Local Call] Digits to delete Default No.1: 3, Others: 0 Value Range Description/Function Specifies the number of digits to be deleted from the telephone number (sent from the Central Office by Caller ID Service) to make up a telephone number for local call. Digits are removed from the beginning of the received digits.
  • Page 270 Features Parameter [Long Distance Call] Number to be added Default Value Range Up to 4 digits consisting of 0-9, or # Description/Function Specifies the number to be added to the telephone number (sent from the Central Office by Caller ID Service) to make up a telephone number for long distance call.
  • Page 271: Caller Id Registration

    Features 5.13 Caller ID Registration 5.13.1 Caller ID Registration Used to assign the Caller ID code (identification code of the calling party) to utilise Caller ID Service provided by a specific Central Office (CO). If an ID Code transmitted from CO is found in the Caller ID Code Table, the caller's ID Code or a name given to the code is displayed on the display PT, allowing the called party to recognise the caller before answering a call.
  • Page 272 Features Cancel • If you want to cancel the operation, click Click to continue the operation. • The message "Import..." is displayed and copying the System Speed Dial data begins. • When copying is finished, "5-12 Caller ID Registration" screen is displayed again. Parameter Tenant No.
  • Page 273 Features Parameter Name Default Blank Value Range Up to 16 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function Specifies the name to a Caller ID code. Note •...
  • Page 274: Ucd Time Table

    Features 5.14 UCD Time Table If all extensions in a UCD group are busy, the incoming CO calls will be handled by the UCD Time Table procedure. Up to 32 UCD Time Tables, max.16 steps for each, can be assigned. Parameter Table No.
  • Page 275 Features Parameter Command Sequence (1-16) Default None Value Range None, S1 - S8, 1T - 4T, TR, RET, OFF Description/Function The following commands are provided to construct a UCD Time Table procedure. <Commands list and their functions> None: Skips to the next sequence. S1 - S8: OGM (1-8) is sent to the caller if available.
  • Page 276: Charge

    Features 5.15 Charge Used to assign parameters for the Charge Fee Management feature. Parameter Charge Display on LCD Default Meter Value Range Meter Charge Description/Function Specifies the initial display format of the charge fee on a display Reference • 1.3 System Features (F/G) –...
  • Page 277 Features Parameter [Charge Verification ID Code] Tenant 1-8 Default 1234 Value Range 4-7 digits consisting of 0-9 Description/Function Specifies the ID code required for the charge management. When "Tenant Service" is employed, the password for each tenant (Tenant 1 to 8) can be assigned respectively. Reference •...
  • Page 278 Features Parameter Currency Display Position Default Tail Value Range Head Tail Description/Function Specifies whether the currency of the charge is displayed before (Head) or after (Tail) the charge display. Reference None Parameter Treatment of Charge Limit Default Alarm Tone Value Range Alarm Tone Alarm Tone and Disconnect Disconnect...
  • Page 279: Hotel

    Features 5.16 Hotel Used to assign parameters for Hotel Application. Parameter [Charge] Margin Default 0.0 % Value Range 0-999.9 % Description/Function Specifies a margin rate of telephone charge which will be appended to the Check Out Sheet. Reference • 3.2.6 Hotel Use Features (Hotel Application) [KX-T7536, KX- T7235 only] (U/M) •...
  • Page 280 Features Parameter [Charge] TAX1 Default 30.0 % Value Range 0-200.0 % Description/Function Specifies a tax rate which applies to the item specified by "[Title] 1" setting (default =Telephone). This will be appended to the Check Out Sheet. Reference • 3.2.6 Hotel Use Features (Hotel Application) [KX-T7536, KX- T7235 only] (U/M) •...
  • Page 281 Features Parameter [Title] 1 Default Telephone Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function A tax rate for this item can be set by "[Charge] TAX1"...
  • Page 282 Features Parameter Title Header (3 lines) Default Check Out Sheet Value Range Characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ ( ) + , - / : ; < = > ? @ &. Description/Function Defines the "Title Header"...
  • Page 283 Features Parameter [Data Start] Line Default Value Range 4-24 Description/Function Specifies the start line of the data portion. Reference • 3.2.6 Hotel Use Features (Hotel Application) [KX-T7536, KX- T7235 only] (U/M) • 1.3 System Features (F/G) – Hotel Application Parameter [Data Start] Column Default Value Range...
  • Page 284: T7710 One-Touch Dialling

    Features 5.17 T7710 One-Touch Dialling Used to store up to eight One-Touch Dialling numbers or one message. Parameter Dial Default Key No. 1-8: Blank, Message: 702 Value Range Up to 24 digits consisting of 0-9, , #, F, P, S or "-" (hyphen) Description/Function Specifies the phone number or feature number for KX-T7710 One- Touch Dialling.
  • Page 285: Toll Restriction

    Toll Restriction Section 6 Toll Restriction Programming Guide...
  • Page 286 Toll Restriction 6.1 Toll Restriction Used to assign TRS (Toll Restriction) Deny Codes and TRS Exception Codes. Programming Guide...
  • Page 287: Trs Deny Code

    Toll Restriction 6.2 TRS Deny Code Used to programme a list of up to 400 TRS (Toll Restriction) Deny Codes - telephone numbers that extension users cannot dial. Parameter TRS Level Default Value Range 2 - 6 Description/Function Specifies a TRS (toll restriction) level. Reference •...
  • Page 288 Toll Restriction Parameter Dial Default Blank Value Range Up to 10 digits consisting of 0-9, X, or # Description/Function Specifies the leading 10 digits of the toll-restricted telephone numbers. Note • "X" can be used as a wild card character which substitutes any digit in its position.
  • Page 289: Trs Exception Code

    Toll Restriction 6.3 TRS Exception Code Used to programme a list of numbers that an extension is allowed to dial, even if these numbers are listed in a TRS Deny Code Table. Up to 200 TRS Exception codes can be assigned. Parameter TRS Level Default...
  • Page 290 Toll Restriction Parameter Dial Default Blank Value Range Up to 10 digits consisting of 0-9, X, or # Description/Function Specifies the leading 10 digits of the telephone numbers which are excepted from the toll restriction. Note • "X" can be used as a wild card character which substitutes any digit in its position.
  • Page 291: Ars (Automatic Route Selection)

    ARS (Automatic Route Selection) Section 7 ARS (Automatic Route Selection) Programming Guide...
  • Page 292 ARS (Automatic Route Selection) 7.1 ARS (Automatic Route Selection) Used to assign ARS parameters. Programming Guide...
  • Page 293: Time Table

    ARS (Automatic Route Selection) 7.2 Time Table Used to make up ARS time schedules. It is possible to split a day into four time zones (maximum) so that the least expensive line is selected for that time. Enter the starting time of each zone according to the service hours and charges offered by your carriers.
  • Page 294: Leading Digits Table

    ARS (Automatic Route Selection) 7.3 Leading Digits Table Used to determine the appropriate Route Plan Table number for a call by analysing the extension user-dialled number. Up to 800 Leading Digits entries can be programmed in the system. Parameter Entry No. Default 001-020 Value Range...
  • Page 295 ARS (Automatic Route Selection) Parameter Dial Default Blank Value Range Up to 10 digits consisting of 0-9, , # or X Description/Function Specifies the leading 10 digits of the telephone number which will be routed by ARS procedure. Note • "X" can be used as a wild card character which substitutes any digit in its position.
  • Page 296: Routing Plan

    ARS (Automatic Route Selection) 7.4 Routing Plan Used to specify the Trunk Group number (1-48) and Modified Digit Table number (1-48) to be used for each route plan and time schedule. Up to 48 Routing Plan entries can be programmed in the system. Parameter Plan No.
  • Page 297 ARS (Automatic Route Selection) Parameter [Time-A, -B, -C, -D] Modification Table No. Default None Value Range None, 1-48 Description/Function Specifies the MOD (Modified Digit) table (1-48) which is used to modify the user-dialled number so that it matches the requirements of the carrier.
  • Page 298: Digits Modification Table

    ARS (Automatic Route Selection) 7.5 Digits Modification Table Used to modify the user-dialled number so that it matches the requirements of the carrier. Up to 48 Digits Modification entries can be programmed in the system. Parameter Entry No. Default 01-08 Value Range 01-48 in 8 entries increments Description/Function...
  • Page 299 ARS (Automatic Route Selection) Parameter Number to be added Default Blank Value Range Up to 20 digits consisting of 0-9, , # or P [Pause] Description/Function Specifies the dialling number to be added to the beginning of the user-dialled number. Reference •...
  • Page 300 ARS (Automatic Route Selection) Programming Guide...
  • Page 301: Private Network

    Private Network Section 8 Private Network Programming Guide...
  • Page 302 Private Network 8.1 Private Network Used to assign parameters required to utilise TIE line service. Programming Guide...
  • Page 303: Tie Routing Table

    Private Network 8.2 TIE Routing Table Used to specify trunk groups and parameters required for making TIE calls. This table is referenced by the system to identify the trunk route, when an extension user made a TIE call by dialling the feature number for "TIE Line Access" or "Other PBX 01-16." The first 3 digits (other than TIE Line Access Code) of the dialled number decide a routing pattern appropriate for each call.
  • Page 304 Private Network Parameter Leading Digit Default Blank Value Range Up to 3 digits consisting of 0-9 or X Description/Function Specifies the leading one, two or three digits of the number for TIE calls. Used to determine the trunk group for routing a TIE call. Note •...
  • Page 305: Ddi/Did

    DDI/DID Section 9 DDI/DID Programming Guide...
  • Page 306 DDI/DID 9.1 DDI/DID Used to assign parameters required to utilise DDI/DID service. Programming Guide...
  • Page 307: Number Transformation

    DDI/DID 9.2 Number Transformation 9.2.1 Number Transformation Used to specify several parameters for DDI / DID / MSN service. Parameter Entry No. Default 0001-0010 Value Range 0001-1000 in 10 entries increments Description/Function Specifies the entry number of DDI / DID / MSN No. which you are going to programme.
  • Page 308 Up to 16 digits consisting of 0-9 Description/Function Specifies the DDI / DID / MSN number which will be sent from the Central Office to the KX-TD500 system. Note • The DDI / DID / MSN number which has already been assigned cannot be registered.
  • Page 309 DDI/DID Parameter VPS Trunk Group No. Default Value Range 1-48 Description/Function Specifies the trunk group used for the call to the VPS when "DID / DDI No." is specified in "Tenant Select Mode for DID / DDI" programming in Section "2.8 System Option." Reference •...
  • Page 310 DDI/DID Parameter MSN Line No. Default Blank Value Range Physical number of the trunk port Description/Function Specifies the physical number of the trunk port. This port will be used to forward a call by ISDN Line. Reference • 2.5 ISDN Transferring Features (F/G) –...
  • Page 311 DDI/DID 3. Click • The following DDI / DID / MSN numbers are registered in Entry Nos. 1–100 of "DDI / DID / MSN No." automatically. Programming Example: Entry No.1 : 123456 (00) Entry No.2 : 123456 (01) Entry No.3 : 123456 (02) •...
  • Page 312 DDI/DID Parameter [Additional Number] Number of Registrations Default 10 entries Value Range 10-100 entries in 10 entries increments Description/Function Specifies the number of DDI / DID / MSN entries to be registered automatically. Reference None Parameter [Additional Number] Number of Digits Default 2 digits (00-99) Value Range...
  • Page 313: Maintenance

    Maintenance Section 10 Maintenance Programming Guide...
  • Page 314 Maintenance 10.1 Maintenance Used to assign parameters for system maintenance. Programming Guide...
  • Page 315: External Modem 1/2

    Maintenance 10.2 External Modem 1/2 The system supports an external modem plugged into the RS-232C port for remote system administration. Parameter Manual Initialization Command (1- 5) Default All: Blank Value Range Up to 80 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ;...
  • Page 316 Specifies Modem Automatic Initialisation Command. Note • A hardware flow control cannot be done by the communication port of KX-TD500. Therefore, the hardware flow control of your modem must be disabled to communicate correctly. It depends on the type of the modem you use.
  • Page 317: External Modem 2/2

    Maintenance 10.3 External Modem 2/2 Parameter Connection Message (1-5) Default Message 1: CONNECT, Others: Blank Value Range Up to 80 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function Specifies Connection Message from Modem.
  • Page 318: Smdr

    Maintenance 10.4 SMDR 10.4.1 SMDR 1/2 Station Message Detail Recording (SMDR) automatically records detailed information for outside calls. Parameter SMDR Connection Default Value Range Description/Function Enables or disables SMDR. Reference • 2.8.4 Personal Computer / Printer (I/M) Programming Guide...
  • Page 319 Maintenance Parameter Output Type Default Type-A Value Range Type-A Type-B Type-C Type-D Type-E Description/Function Specifies the output type of SMDR printout. For further information, please refer to "Station Message Detail Recording (SMDR)" of Section "1.3 System Features" in the Features Guide. You can also get information on "Output Type"...
  • Page 320 Maintenance Parameter [Format] Skip Perforation Default Value Range 0-95 lines Description/Function Determines the number of lines to be skipped at the end of every page. The number of lines to skip is simply the number specified in this parameter. The number of lines printed is the difference between the Page Length number and the Skip Perforation number.
  • Page 321 Maintenance Parameter Print out Caller ID Information Default Number Value Range Number Number + Name Name Disable Description/Function SMDR can print out Caller ID information. This setting specifies whether priority is given to Caller ID Name or to Caller ID Number.
  • Page 322 Maintenance Parameter Print out Timed Reminder Information Default Disable Value Range Enable Disable Description/Function If this is enabled, SMDR will print out "Timed Reminder / Start" each time the timed reminder alarm starts ringing. In addition, if it is answered, SMDR will print out "Timed Reminder / Answer," and if it is not answered, SMDR will print out "Timed Reminder / No Answer."...
  • Page 323 Maintenance Parameter Print out Absent Message (6-9) Default Disable Value Range Enable Disable Description/Function Specifies whether or not Absent Message (6-9) will be printed out by SMDR. If enabled, any extension user can activate the printout by setting the Absent Message (6-9). Reference •...
  • Page 324 Maintenance 10.4.2 SMDR 2/2 Station Message Detail Recording (SMDR) automatically records detailed information for outside calls. Parameter Print out supplementary digits (ISDN only) Default Disable Value Range Enable Disable Description/Function Includes the SMDR printout of outgoing supplementary digits. This is only available on ISDN calls. Note •...
  • Page 325: Power Failure Transfer

    Maintenance 10.5 Power Failure Transfer Power Failure Transfer connects specific telephones (any SLT and a certain type of APT) to pre-determined CO lines in the event of system power failure. Parameter Trunk Card (1-24) Default None Value Range None, XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the trunk card number and its type, which will be used in case of Power Failure Transfer.
  • Page 326 Maintenance Parameter Extension Card (1-24) Default None Value Range None, XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the extension card number and its type, which will be used in case of Power Failure Transfer. Notes •...
  • Page 327: System Parameters

    Maintenance Console software from a PC (Personal Computer). There are four passwords for System Programming by PC. To prevent unauthorised access to the interactive User Programming and Maintenance mode, the KX-TD500 System provides the following four passwords with a different security level respectively. • [Password] System Programming - Protection Level 1 Allows the administrator to access all System Programming and Maintenance features without restrictions.
  • Page 328 PC and check the Password with programming screen. • If you don't have the backup system data, you have to programme again or contact your Panasonic dealers. The higher the password level (level 1 is the highest) is, the more programming items the...
  • Page 329 Maintenance Parameter [Password] System Programming – Protection Level 2 Default 1234 Value Range 4-7 digits of alphanumeric characters Description/Function Specifies the password required for entering the System Programming and Maintenance mode from a PC. Reference • 3.5 Operational Mode (I/M) •...
  • Page 330 Maintenance Parameter [Password] Walking COS Default 1234 Value Range 4-7 digits consisting of 0-9 Description/Function Specifies the password required for using the Walking COS feature. Reference • 1.6 Originating Features (F/G) – Walking COS • 2.2.5 Calling without Restrictions (U/M) [Serial Interface Port] PROG (Port 1) Please refer to "System Programming and Diagnosis with Personal Computer"...
  • Page 331 Maintenance Parameter [Serial Interface Port] PROG – Word Length Default (Display only) Value Range 8 bits Description/Function Defines the number of bits in each byte or character. Note • Port 1 is fixed to 8 bits. Reference None Parameter [Serial Interface Port] PROG – Stop Bit Default (Display only) Value Range...
  • Page 332 Maintenance Parameter [Serial Interface Port] SMDR – Parity Default None Value Range None Mark Space Even Description/Function A parity code indicates what type of parity is used to detect an error in the string of bits composing a character. Make an appropriate selection depending on the requirements of your printer or personal computer.
  • Page 333 Maintenance Parameter [Serial Interface Port] SMDR – Stop Bit Default 1 bit Value Range 1 bit 2 bits Description/Function A stop bit code indicates the end of a bit string which composes a character. Select an appropriate value depending on the requirements of your printer or personal computer.
  • Page 334 Maintenance Parameter [Remote Connect Information] Dial Number Default Blank Value Range Up to 40 digits consisting of 0-9, , #, F, P, S or "-" (hyphen) Description/Function Specifies the dial number that is sent from the modem (remote location). You can see this dial number in the Batch Processing mode.
  • Page 335: System Time

    Maintenance 10.7 System Time Used to assign System Time. Please refer to the following: • 1.8 Ringing Features (F/G) – Timed Reminder (Wake-Up Call) – Timed Reminder, Remote (Wake-Up Call) • 1.17 Display Features (F/G) – Display, Date and Time •...
  • Page 336 Maintenance Parameter (Day) Default Value Range 01-31 Description/Function Specifies the date in two digits by entering the value directly. Reference None Parameter (Day of the week) Default Value Range Sun-Sat Description/Function Selects the day of the week by clicking the small triangle. Reference None Parameter...
  • Page 337 Maintenance Summer Time / Daylight-saving Time Setting Note The start and end dates of the summer time can be programmed. The system clock will be adjusted (one hour forward or backward) at 2:00 AM of the programmed date, if enabled. It means 2:00 AM will become 3:00 AM on the start date of the summer time, and 2:00 AM will become 1:00 AM on the end date.
  • Page 338 Maintenance Parameter End (Day) Default Blank Value Range 01-31 Description/Function Specifies the date in two digits by entering the value directly. Reference None Parameter Start (Year) Default Blank Value Range 00-99 Description/Function Specifies the last two digits of the year by entering the value directly.
  • Page 339: Programming Error Messages

    Programming Error Messages Section 11 Programming Error Messages Programming Guide...
  • Page 340: Error Messages (Exxxx)

    Programming Error Messages 11.1 Error Messages (EXXXX) Error Message Error Code Description E0000 System error. (Error code : XXX) A system error occurred. Please inform your distributor how the error was generated and what the error code was. E0001 Cannot create temporary file. There is insufficient free space on your hard disc or this software is not installed correctly.
  • Page 341 Programming Error Messages Error Message Error Code Description E0012 Another maintenance device is connected. There are three ways to access the PBX: (1) By PC System Programming, (2) by Remote System Programming, or (3) by User Programming. But only one at a time. E0013 Please reconnect after the PBX becomes on-line or off-line completely.
  • Page 342 Programming Error Messages Error Message Error Code Description E1006 You have exceeded the system limit of AGC cards. There is a limit of 8 AGC cards per system. E1007 You have exceeded the system limit of remote cards. One RMT card or one ERMT card can be installed in the system -- only one. E1008 You have exceeded the system limit of DPH cards.
  • Page 343 Programming Error Messages Error Message Error Code Description E1023 Assign the directory numbers for EXT#1 and EXT#2. For the VPS port you must assign directory numbers for both voice mail numbers, EXT#1 and EXT#2. These cannot be assigned individually. E1024 Cannot assign the port which does not have VPS (DPT) attribute.
  • Page 344 Programming Error Messages Error Message Error Code Description E1037 Cannot change the status of the port. Cannot change the status of the SLT port because the PT port is activated as a "Parallel Mode" extension. Please change the PT port status to "XDP Mode" and then press "Apply."...
  • Page 345 Programming Error Messages Error Message Error Code Description E1059 VPS card duplicated. Each physical number of the VPS Card (Jack 1-8) and VPS Card (Jack 9-12) must be assigned uniquely. E1060 You have exceeded the limit of VPS(DPT) port per DLC card. There is a limit of 8 VPS(DPT) ports per DLC card.
  • Page 346 Programming Error Messages Error Message Error Code Description E2013 Invalid directory number for Operator FDN. Only FDN of an extension group and incoming group can be assigned as an Operator FDN. E3001 Invalid directory number for intercept destination. There are six possible destinations for intercepted calls: (1) An extension, (2) an external pager (TAFAS), (3) an OGM group, (4) an extension group, (5) an incoming group, or (6) a phantom extension.
  • Page 347 Programming Error Messages Error Message Error Code Description E4007 Single - CO key duplicated. Please assign the Single - CO key that has the different CO physical number on one PT. E4008 Invalid directory number for DSS (DN) or VTR key. Only DN of an extension can be assigned as DSS (DN) or VTR key.
  • Page 348 Programming Error Messages Error Message Error Code Description E4024 DN or FDN must be entered to assign the type of key. You must enter the DN or FDN when you assign key type "DSS," "Phantom," "SDN," "VTR," "2WAY-REC" and "2WAY-TRN." Each key needs following directory number as DN or FDN: - DSS Extension directory number which is in existence.
  • Page 349 Programming Error Messages Error Message Error Code Description E5006 Cannot assign more than 1000 account codes. There is a limit of 1000 account codes per system. E5007 You have exceeded the tenant limit of Speed Dialing numbers. The maximum number of Speeding Dialling numbers per tenant is specified in "2-1 Tenant"...
  • Page 350 Programming Error Messages Error Message Error Code Description E9001 Invalid directory number for DDI / DID destination. There are seven possible destinations for DDI / DID calls: (1) An extension, (2) an external pager (TAFAS), (3) an OGM group, (4) a remote extension, (5) an extension group, (6) an incoming group, or (7) a phantom extension.
  • Page 351: Warning Messages (Wxxxx)

    PC software? PC software (Maintenance Console software) is not compatible with the current KX- TD500 software. Load the appropriate PC software into your PC. (Then connect your PC to the KX-TD500 again.) W1001 Change the card (XXX:YYY) status? Please confirm whether or not to execute OUS (Out-of-Service) / INS (In-Service) command to the card "XXX:YYY"...
  • Page 352 Programming Error Messages Message Code Description W3002 Please verify that previously erased FDN is not programmed in other screens. The erased FDN may be used in other screens. W4001 Trunk name must not exceed 10 characters. Truncate it? Truncate means that the leading 10 characters are saved and the rest are deleted. W4002 Extension name must not exceed 10 characters.
  • Page 353 Programming Error Messages Message Code Description W5010 Voice Mail command must not exceed 16 digits. Truncate it? Truncate means that the leading 16 digits are saved and the rest are deleted. W5011 Local Area Code must not exceed 6 digits. Truncate it? Truncate means that the leading 6 digits are saved and the rest are deleted.
  • Page 354 Programming Error Messages Message Code Description W9005 Base dial number must not exceed 15 digits. Truncate it? Truncate means that the leading 15 digits are saved and the rest are deleted. W9006 Remote Information must not exceed 40 digits. Truncate it? Truncate means that the leading 40 digits are saved and the rest are deleted.
  • Page 355: Information Message (Ixxxx)

    Programming Error Messages 11.3 Information Message (IXXXX) Message Code Description I0001 Upload completed. Please change PBX to on-line mode. Uploading the system programming data from PC to PBX is completed. How to change PBX to on-line mode: 1. Set CPU Mode Rotary-Switch position to 0. 2.
  • Page 356 Programming Error Messages Programming Guide...
  • Page 357: Default Values

    Default Values Section 12 Default Values Programming Guide...
  • Page 358 Default Values 1 Configuration 1.1 Configuration 1.2 Slot Assignment Programme Default Card Type Blank Status — 1.3 Trunk Port Assignment Programme Default Card No. — Group No. DID/DID-2W/DID-MFC card: 47, E&M card: 48, Others : 1 Status — 1.4 Extension Port Assignment Programme Default Card No.
  • Page 359 Default Values Programme Default Type None Jack No. (Display only) Port No. Blank [Ext No.1] DN Blank [Ext No.1] Group No. Blank [Ext No.2] DN Blank [Ext No.2] Group No. Blank Status — DN Refer — 1.6 T1 Port Assignment Programme Default Card No.
  • Page 360 Default Values Programme Default [Card No. 1-8] OGM Group No. 1.9 BRI Port Assignment Programme Default Card No. — Type Blank Group No. Status — DN Refer — 1.10 PRI Port Assignment Programme Default Card No. — Type Blank Group No. Status —...
  • Page 361 Default Values Programme Default Day (SUN-SAT) 9:00 AM Night (SUN-SAT) 5:00 PM Lunch - Start (SUN-SAT) 12:00 PM Lunch - End (SUN-SAT) 1:00 PM Break - Start (SUN-SAT) 3:00 PM Break - End (SUN-SAT) 3:30 PM Music on Hold Source MUS1 BGM Source MUS1...
  • Page 362 Default Values Programme Default 19 Trunk Group Access 20 Speed Dialing - System 21 Speed Dialing - Station 22 Speed Dialing - Station Programming 23 Doorphone Call 24 External Paging 25 External Paging Answer / TAFAS Answer 26 Station Paging 27 Station Paging Answer 28 CO Call Pickup 29 Group Call Pickup...
  • Page 363 Default Values Programme Default 50 Station Lock Set / Cancel 51 Night Mode Set / Cancel 52 Parallel Telephone Mode 53 External BGM On / Off 54 Live Call Screening 55 Call Log Incoming, Overwrite Mode 56 Call Log Incoming, Log Lock 57 Timed Reminder, Remote 58 Login / Logout 59 Automatic Callback Busy Cancel...
  • Page 364 Default Values Programme Default 103 Group Login / Logout 104 Group FWD 105 Print out Room Service 106-120 Reserved (Reserved for future use.) Blank 2.4 Class of Service (COS) 2.4.1 Class of Service (COS) 1/2 Programme Default COS No. Trunk Group Setting —...
  • Page 365 Default Values 2.4.2 Trunk Group Setting Programme Default Trunk Group No. 01-48 – Day / Night All: Check 2.4.3 Class of Service (COS) 2/2 Programme Default Secret Busy Override Disable Transferring CO dial tone (exempted from TRS) Enable Transfer to TIE Disable Incoming Group FWD Disable...
  • Page 366 Default Values 2.5.2 System Timer 2/2 Programme Default Timed Reminder Ringing Time 30 s Call Parking Recall Time 60 s TIE Inter-digit Time DISA Prolong Time 3 min DISA Delayed Answer Time 1 ring Timed Reminder Arrive Count 3 times DISA Automated Attendant Time DISA IRNA Time 60 s...
  • Page 367 Default Values Programme Default 5. Limited call duration Both calls 6. Transfer recall destination Originating extension 7. Checking dial *, # by toll restriction Check 8. Confirmation tone for Override, Barge-in, Enable Conference and Privacy Release 9. Confirmation tone for Call Pickup, Paging, Enable Paging- Answer, TAFAS-Answer, Hold...
  • Page 368 Default Values Programme Default 26. Pressing CO/DN/Answer key operation in Hold talking 27. Message Waiting lamp pattern 28. Trunk hunting mode Forced 29. Card CODEC Mu Law 30. Net CODEC Mu Law: [HK], A Law: Others 2.8.4 System Option 4 Programme Default 31.
  • Page 369 Default Values 2.8.5 System Option 5 Programme Default 50. Dial / Ringback tone frequency Normal 51. Release of BRI/PRI line while on-hold when Release 'DISCONNECT' signal is received 52. Sending Mode of CLIP while CLIR is enabled Private Network (Q-Sig Line only) 53.
  • Page 370 Default Values 2.9 Language Data 3 Group 3.1 Group 3.2 Trunk Group 3.2.1 Trunk Group 1/2 Programme Default Group No. Type Public Copy — Intercept Destination – Day / Night Blank Pause Time before Flash Signal 512 ms Max. Dial No. after EFA Signal Line Hunting Order Normal Tenant No.
  • Page 371 Default Values 3.2.2 Trunk Group 2/2 Programme Default ISDN Progress Tone Mode Automatic Sending ISDN FLASH signal to CO Disable 3.3 Extension Group Programme Default Group No. Copy — Blank DN Refer — Tenant No. [Overflow Setting] Destination – Day / Night Blank [Overflow Setting] Timer None...
  • Page 372 Default Values Programme Default Extension Group No. Paging Group No.1 = No.1: 1, No.2: 128, Others: None / Paging Group No.2-No.16 = All: None 3.5 Incoming Group Programme Default Group No. Copy — Blank DN Refer — Group Type DIL 1:N [Overflow Setting] Destination –...
  • Page 373 Default Values 3.6 OGM Group Programme Default Group No. Blank DN Refer — Tenant No. OGM Type DISA Security Mode Trunk [DISA built-in Automated Attendant Tables] Dial Blank 0 - Dial 9 4 Line 4.1 Line 4.2 Trunk Line Programme Default Card No.
  • Page 374 Default Values Programme Default [DDI / DID / TIE] Number to be added Blank Digit to receive DDI / DID 4 (DID / DID-2W / DID-MFC / E1[DR2] / T1[DID] card), 16 (BRI / PRI23 / PRI30 card) Collect Call Enable Wink Signal Time-out 1024 ms...
  • Page 375 Default Values 4.3 Extension Line 4.3.1 Extension Line 1/2 Programme Default Card No. — Port No. — Group No. (Display only) Copy — Name Blank Message Lamp Mailbox No. Same as the extension number CO Key — PF Key — Initial Display Selection Caller ID Charge Limit...
  • Page 376 Default Values Programme Default ISDN Bearer Mode Automatic JOG Dial Speed Normal [CLIP / COLP Number] Public Blank [CLIP / COLP Number] Private Blank [Call Log Incoming] Overwrite Mode [Call Log Incoming] Lock Password Blank 4.3.2 Flexible CO Key Assignment Programme Default Key Type...
  • Page 377 Default Values 4.4.1 Flexible DSS Key Assignment Programme Default Key Type Not Stored 4.4.2 Flexible PF Key Assignment for DSS Console Programme Default Key Type Not Stored 4.5 Doorphone Programme Default Card No. — Port No. Tenant No. Destination – Day / Night Blank 4.6 External Paging Programme...
  • Page 378 Default Values Programme Default Charge Limit Tone Disable ISDN Bearer Mode Automatic Numbering Plan ID Default Type of Number Default [CLIP / COLP Number] Public Blank [CLIP / COLP Number] Private Blank [COS No.] Primary [COS No.] Secondary Receiving ISDN FLASH signal Place the call on consultation HOLD 4.8 PC Console Line 4.8.1 PC Console Line 1/2...
  • Page 379 Default Values Programme Default [Pickup Dialing] Mode Disable [Pickup Dialing] Dial (Display only) [LCS Setting] Status Inactive [LCS Setting] Operation Mode Hands-free [LCS Setting] Recording Mode Stop Rec [LCS Setting] LCS Password Blank Data Line Mode Call Waiting Tone Type Tone 1 Call Pickup Deny Disable...
  • Page 380 Default Values Programme Default Current Registration (Display only) Name Blank Number Blank 5.3 Phantom Extension Programme Default Entry No. 001-048 Blank DN Refer — 5.4 Emergency Dial Code Programme Default Dial All: Blank 5.5 Quick Dialling Programme Default Dial All: Blank 5.6 Account Code Programme Default...
  • Page 381 Default Values 5.8 Waiting Second Dial Tone Code Programme Default Entry No. 001-020 Mode Disable [Waiting Second Dial Tone Code] Dial All: Blank [Waiting Second Dial Tone Code] Pause None 5.9 Absent Message Programme Default Message MSG1: Will Return Soon, MSG2: Gone Home, MSG3: At Ext %%%% (Extension No.), MSG4: Back at %% : %% (Hour: Minute), MSG5: Out Until %% / %% (Month / Day), MSG6: In a Meeting,...
  • Page 382 Default Values Programme Default [Integration Code] FWD to VM Ringback Tone [Integration Code] FWD to VM Busy Tone [Integration Code] FWD to Extension Ringback Tone Voice Mail Command [Voice Mail Command] Leave Message [Voice Mail Command] Get Message [Voice Mail Command] AA Service [Voice Mail Command] VM Service 5.11.2 VPS Integration 2/2 Programme...
  • Page 383 Default Values 5.13 Caller ID Registration 5.13.1 Caller ID Registration Programme Default Tenant No. Entry No. 0001-0010 Import from Sys. Speed Dial — Name Blank Number Blank 5.14 UCD Time Table Programme Default Table No. Command Sequence (1-16) None 5.15 Charge Programme Default Charge Display on LCD...
  • Page 384 Default Values Programme Default [Charge] TAX3 30.0 % [Title] 1 Telephone [Title] 2 Minibar [Title] 3 Others Title Header (3 lines) Check Out Sheet [Header Start] Line [Header Start] Column [Data Start] Line [Data Start] Column Language English 5.17 T7710 One-Touch Dialling Programme Default Dial...
  • Page 385 Default Values 7 ARS (Automatic Route Selection) 7.1 ARS (Automatic Route Selection) 7.2 Time Table Programme Default Time A,-B,-C,-D, (SUN, MON, TUE, WED, Time-A=8:00AM, Time-B=5:00PM, Time- THU, FRI, SAT) C=9:00PM, Time-D=Disable 7.3 Leading Digits Table Programme Default Entry No. 001-020 Dial Blank Routing Plan No.
  • Page 386 Default Values 8 Private Network 8.1 Private Network 8.2 TIE Routing Table Programme Default Entry No. 01-08 PBX Code Blank Leading Digit Blank Digits to delete Number to be added Blank Trunk Group No. None 9 DDI/DID 9.1 DDI/DID 9.2 Number Transformation 9.2.1 Number Transformation Programme Default...
  • Page 387 Default Values Programme Default Beginning Entry No. 1 (Entry No.1) 10 Maintenance 10.1 Maintenance 10.2 External Modem 1/2 Programme Default Manual Initialization Command (1- 5) All: Blank Automatic Initialization Command AT&F0Q0E0V1S0=1X0&D0 10.3 External Modem 2/2 Programme Default Connection Message (1-5) Message 1: CONNECT, Others: Blank Disconnection Message (1-5) Message 1: NO CARRIER, Others: Blank...
  • Page 388 Default Values Programme Default Print out LOGIN / LOGOUT Disable Print out Absent Message (6-9) Disable Print out Check-in / Check-out Disable Time Display Mode 10.4.2 SMDR 2/2 Programme Default Print out supplementary digits (ISDN only) Disable 10.5 Power Failure Transfer Programme Default Trunk Card (1-24)
  • Page 389 Default Values Programme Default [Serial Interface Port] PROG – Baud Rate 19200 bps [Serial Interface Port] SMDR (Port 2) [Serial Interface Port] SMDR – Parity None [Serial Interface Port] SMDR – NL Code CR + LF [Serial Interface Port] SMDR – Word Length 8 bits [Serial Interface Port] SMDR –...
  • Page 390 Default Values 11 Programming Error Messages 11.1 Error Messages (EXXXX) 11.2 Warning Messages (WXXXX) 11.3 Information Message (IXXXX) Programming Guide...
  • Page 391 Default Values Programming Guide...
  • Page 392 1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan Copyright: • This manual is copyrighted by Panasonic Communications Co., Ltd. (PCC). You may print out this manual solely for internal use with this model. Except above, you may not reproduce this manual in any form, in whole or part, without the prior written consent of PCC.