Ductless S plit Air Conditioner Installation M anual Indoor Outdoor AW09ES2VH* 1U09ES2VHA AW12ES2VH* 1U12ES2VHA AW18ES2VH* 1U18ES2VHA AW24ES2VH* 1U24ES2VHA AW09TE1VH* 1U09TE1VHA AW12TE1VH* 1U12TE1VHA AW18TE2VH* 1U18TE2VHA AW24TE2VH* 1U24TE2VHA Table of Contents Step 1 - Preparation ........................2 Step 2 - Installation of the Indoor Unit ................... 3 Step 3 - Installation of the Out door Unit..................
Step 1 - Preparation Required Tools for Installation Procedure for Selecting the Location Note: detector place. Clearances of Indoor and Outdoor Units The models adopt HFC free refrigerant R410A Attention must be paid to more than 4in. the pitch of drain hose Floor xing dimensions of the outdoor unit (Unit: inch) more than...
Step 2 - Installation of the Indoor Unit Attaching the Mounting Plate to the Wall Step 2.1 Using a stud sensor, locate and mark the stud positions in the wall where the indoor unit is to be mounted. Step 2.2 Place the mounting plate on the wall in the desired location taking into account the minimum clearances necessary for Step 2.1...
Mounting the Indoor Unit Onto the Wall Plate Step 2.9 With the top of the indoor unit closer to the wall, hang the indoor unit on the upper hooks of the mounting plate. Slide the unit slightly side to side to verify proper placement of the indoor unit on the mounting plate.
Step - 3.3 Connect the wiring for both the power source and indoor wiring. Wire the system according to applicable national / local codes. Verify that the wiring connections for the indoor unit match wire for wire. Step 3.3 Step 3.4 (1-1, 2-2, 3-3, Gnd-Gnd).
Page 6
Step 5 - Leak Test and Evacuation Leak Test +D]DUG RI ([SORVLRQ 1HYHU XVH DQ RSHQ DPH WR GHWHFW JDV leaks. Explosive conditions may occur. Use a leak test solution or other approved methods for leak testing. Failure to follow recommended safe leak test procedures could result In death RU VHULRXV LQMXU\ RU HTXLSPHQW RU SURSHUW\ GDPDJH Use only dry nitrogen with a pressure regulator for...
piping hole. Use a sealant to seal the piping hole opening to prevent weather elements from entering the building. (Illustration 6) Less than Verify the condensate drain line has a constant pitch It becomes The end is imm- There is the bad It waves.
Section 7 - Explaining Operation t o the End User operation, etc.) ATING INS TRUC TIONS carefully . Model Name Outdoor 1U09ES2VHA 1U12E S2VHA 1U18ES2VHA 1U24ES2VHA AW09ES2VH* Indoor AW24ES2VH* AW12ES2VH* AW18ES2VH* Cooling °F(°C) 14~115(-10~46) 14~115(-10~46) 14~115(-10~46) 14~115(-10~46) Operating Range Heating °F(°C) -4-75(-20-24) -4-75(-20-24) -4-75(-20-24)