Configuring Global Attributes for Fibre Channel Interfaces
Command or Action
Step 4
switch(config)# system default switchport
trunk mode auto
About N Port Identifier Virtualization
N port identifier virtualization (NPIV) provides a means to assign multiple FC IDs to a single N port. This
feature allows multiple applications on the N port to use different identifiers and allows access control, zoning,
and port security to be implemented at the application level. The following figure shows an example application
using NPIV.
Figure 1: NPIV Example
Enabling N Port Identifier Virtualization
To enable or disable NPIV on the switch, perform this task:
Before You Begin
You must globally enable NPIV for all VSANs on the switch to allow the NPIV-enabled applications to use
multiple N port identifiers.
All of the N port identifiers are allocated in the same VSAN.
Note
SUMMARY STEPS
1. switch# configuration terminal
2. switch(config)# feature npiv
3. switch(config)# no npiv enable
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide
22
Purpose
Configures the default setting for administrative trunk mode state of an
interface as Auto.
The default setting is trunk mode
Note
on.
Configuring Fibre Channel Interfaces
OL-xxxxx-xx