Hazardous Location Installation Information
Hazardous Locations Standards
Hazardous Locations Standards
Hazardous location standards for the Cisco IE 4000 switches:
Environmental Ranges
Operating temperature
Storage temperature
Operating altitude
Storage altitude
Thermal spacing
Power Requirements
AC input voltages
Maximum AC power input current
DC input voltages
Maximum DC input current
Physical Dimensions
Weight
Dimensions (W x D x H)
The following standards were used for the hazardous
locations approvals and certifications:
ANSI/ASA 12.12.01-2013
CAN/CSA C22.2 No. 60079-0: 11
CAN/CSA C22.2 No. 60079-15:12
CSA C22.2 No. 213-M1987
EN 60079-0:2012+A11:2013
EN 60079-15:2010
IEC 60079-0 6th Edition
IEC 60079-15 4th Edition
UL 60079-0, 5th Ed, 2009-10-21
UL 60079-15, 3rd Ed, 2009-7-17
–29 to 165°F (–34 to 74°C)
–40 to 185°F (–40 to 85°C)
Up to 13,000 ft (3962 m)
Up to 40,000 ft (12,192 m)
3.54 in. (90 mm) exposed side
4.13 in. (105 mm) top and bottom
Range: 85–264 VAC at 47–63 Hz
Nominal: 115 VAC at 60 Hz or 230 VAC at 50 Hz
0.75 A @ 230 VAC and 50 Hz or
1.3 A @ 115 VAC and 60 Hz
Range: 88–375 VDC
Nominal: 125 VDC or 250 VDC
0.75 A at 220 VDC or
1.25 A at 150 VDC
1.4 lb (0.63 kg)
2 x 4.62 x 5.81 in. (50.8 x 117.5 x 147.6 mm)
Note:
Width includes the cosmetic end-caps. Height does not include the
panel mount brackets. Depth is the distance from the rail.
Les normes suivantes ont été appliquées pour les
approbations et les certifications dans le cadre
d'environnements dangereux :
ANSI/ASA 12.12.01-2013
CAN/CSA C22.2 n° 60079-0 : 11
CAN/CSA C22.2 n° 60079-15 :12
CSA C22.2 n° 213-M1987
EN 60079-0:2012+A11:2013
EN 60079-15:2010
IEC 60079-0, 6e édition
IEC 60079-15, 4e édition
UL 60079-0, 5e éd., 21-10-2009
UL 60079-15, 3e éd., 17-07-2009
73