UNIVERGE SV8100
Timer
Timer
Class 0
Class 1~15
25-07-08
20-31-20
25-07-09
20-31-21
25-07-10
20-31-22
31-01-02
20-31-23
Conditions
Timer Classes are used for CAR/VE also.
When Timer Class is set to 0 it uses the system-wide timers.
All stations and trunks are assigned to Timer Class 0 at default.
Both system-wide timers (Timer Class 0) and Timer Class timers (Timer Class 1~15) can
be used in the same system.
Default Setting
Timer Class set to 0 for all trunks and extensions.
System Availability
Terminals
All Multiline Terminals
Flexible Timeouts
Title
Long Conversation
Disconnect Time
DISA Internal Paging Time
DISA External Paging Time
Page Announcement
Duration
Comment
This timer determines how long the system waits
before disconnecting a trunk-to-trunk conversation
call after the Long Conversation tone is heard.
Trunk Timer Class is referred.
This is the maximum length of an Internal Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
This is the maximum length of an External Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
This timer sets the maximum length of External
Page announcements. Station or Trunk Timer
Class is referred by the caller makes
announcement.
Issue 5.0
1 - 523