Technical data

13.8 Construction

Rated conditions for level
Note
Measuring cell with silicone oil
filling
Display
Storage temperature
Climate class
Condensation
Degree of protection in accord-
ance with EN 60529
Degree of protection in accord-
ance with NEMA 250
Electromagnetic compatibility
Interference emission and inter-
ference immunity
Process medium conditions
Process temperature
Measuring cell with silicone oil
filling
13.8
Construction
Construction for gauge pressure and absolute pressure (from the gauge pressure series)
Weight
Material
Wetted parts materials
Process connection
Oval flange
Seal diaphragm
Non-wetted parts materials
Electronics housing
Mounting bracket
218
Observe the allocation of the max. permissible operating temperature to the max.
permissible operating pressure of the relevant flange connection.
-40 ... +85 °C (-40 ... +185 °F)
-30 ... +85 °C (-22 ... +185 °F)
-50 ... +85 °C (-58 ... +185 °F)
Permitted
IP66
NEMA 4X
In accordance with EN 61326 and NAMUR NE 21
Plus side: See mounting flange
Low-pressure side: -40 ... +100 °C (-40 ... +212 °F)
Approx. 1.5 kg (3.3 lb) for aluminum enclosure
Stainless steel, mat. no. 1.4404/316L or Hastelloy C4, mat. no. 2.4610
Stainless steel, mat. no. 1.4404/316L
Stainless steel, material no. 1.4404/316L or Hastelloy C276, material no. 2.4819
Copper-free die cast aluminum GD-AlSi 12 or stainless steel precision casting,
mat. no. 1.4408
Standard: Powder coating with polyurethane
Option: 2 coats: Coat 1: epoxy-based; coat 2: polyurethane
Stainless steel nameplate
Steel or stainless steel
SITRANS P DS III/P410 with PROFIBUS PA
Operating Instructions, 02/2016, A5E00053276-08