4.4
Vario box
The cold air flows in the rear area into the air inlet opening and moves
through the left side panel to the air outlet. The air flow rate is con-
trolled by an NTC sensor in the rear panel and via a flap in the air out-
let opening.
The flap is heated:
Heater = 5 W,
Flap open = heater off
Flap closed = heater on
823_58300000113594_ara_en_u – 26.03.2015
Test programme
Enter programme:
►
Hold down the Select button for 2 sec.
The Vario box temperature is displayed
►
Press the Select button once
OP is displayed and the Vario box flap is opened.
►
Press the Select button twice
CL is displayed and the Vario box flap is closed.
Exit programme:
Automatically after 20 sec.
Vegetables = 3 °C (required tempera-
ture)
Fish = –1 °C (required temperature)
Meat = –3 °C (required temperature)
Off = Vario box not supplied with cold
air
Select = Temperature selection
Seite 9 von 50