Page 2
. COPYRIGHT ⓒ 1997 SAMSUNG ELECTRONICS Co. All rights reserved. No part of this manual may be reproduced in any form or by any means --- graphic, electronic or...
NX-308, NX-820 and NX-1232. 1.1 NX-308 SYSTEM The NX-308, with a maximum capacity of three telephone C.O. lines and eight stations, is an analog telephone system designed for the small-sized business. A powerful H M 6 4 1 8 0 R 1 digital microprocessor controls all speech paths and system functions.
GENERAL DESCRIPTION SECTION HYBRID KEY SYSTEM 3. SYSTEM CONFIGURATION 3.1 NX-308 SYSTEM The basic KSU (Key Service Unit) comes equipped to operate three telephone lines and eight stations. Station #1 is assigned to be used with a keyset and stations #2 through #8 are assigned as keysets or single-line telephones.
1GENERAL 1999.9.15 12:46 PM 페이지9 NX-SERIES GENERAL DESCRIPTION SECTION HYBRID KEY SYSTEM 3.3 NX-1232 SYSTEM The basic KSU (Key Service Unit) comes equipped to operate eight telephone lines and sixteen stations. Stations #1 through #8 are assigned to be used with keysets or single line telephones, and stations #9 through #16 are assigned for single line telephones.
● Processing, switching, and customer memory for all ports. ● Internal music source and External music interface ● 2 Power Failure Transfer ● Back-up Battery for memory protection ● Real Time Clock (RTC) NX-308 SYSTEM NX-820 SYSTEM NX-1232 SYSTEM 3 Trunk interfaces 4 Trunk interfaces...
1GENERAL 1999.9.15 12:46 PM 페이지11 NX-SERIES GENERAL DESCRIPTION SECTION HYBRID KEY SYSTEM 4.3 STATION EQUIPMENT ● Keyset with 24 buttons (NX-24E, NX-24B) ▷ Built-in speakerphone ▷ 24 programmable soft keys (12 with tri-colored LEDs) and 10 fixed-function keys ▷ UP/DOWN buttons for digital control of speaker, handset, and ringer volumes. ▷...
1GENERAL 1999.9.15 12:46 PM 페이지12 NX-SERIES GENERAL DESCRIPTION SECTION HYBRID KEY SYSTEM 5. SPECIFICATIONS 5.1 ELECTRICAL SPECIFICATIONS AC INPUT 110/220 VAC, 50/60 Hz POWER NX-308 50 WATTS MAX CONSUMPTION NX-820 55 WATTS MAX NX-1232 80 WATTS MAX MAX CURRENT NX-308 0.22 AMP...
1GENERAL 1999.9.15 12:46 PM 페이지13 NX-SERIES GENERAL DESCRIPTION SECTION HYBRID KEY SYSTEM 5.5 SYSTEM TONES AND RINGS DIAL TONE : A steady tone that indicates dialing may begin CONTINUOUS RING-BACK TONE : Indicates the station dialed is ringing. 400 ON / 200 OFF/ 400 ON / 3000 OFF BUSY TONE: Indicates the station dialed is busy.
1GENERAL 1999.9.15 12:46 PM 페이지14 NX-SERIES GENERAL DESCRIPTION SECTION HYBRID KEY SYSTEM STATION RING: Indicates an intercom call is ringing on your station. 400 ON / 200 OFF / 400 ON / 3000 OFF DOORPHONE RING: Indicates a doorphone call is ringing on your station. 500 ON / 500 OFF / 500 ON / 500 OFF ALARM RING: Indicates an alarm is ringing on your station.
Page 23
2INSTALL 1999.9.15 12:45 PM 페이지6 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM FIGURE 2-1 MOUNTING THE KSU 2.3 AC Power Selection ( See FIGURE 2-2 ) Before pluging in the KSU, set the AC power selection connector. The Power board of each system has three power connectors. One is for 0V (Ground) and the rest are for 110V/220V selection.
Page 24
2INSTALL 1999.9.15 12:45 PM 페이지8 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 3. INSTALLATION EXPANSION CARDS & OPTION BOARDS Unpack and inspect each card before installing. Check for signs of physical damage. If any damage is detected, do not attempt to install. 3.1 NX-2TRK Card ( See FIGURE 3 - 1 ) Insert the NX-2TRK Card into any expansion slot.
Page 25
2INSTALL 1999.9.15 12:45 PM 페이지10 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 3.8 NX-SMDR/R-MMC Board ( See FIGURE 3 - 7 ) Install the NX-SMDR/R-MMC board on the bottom of the base board. 3.9 NX-DPH/PAGING Board ( See FIGURE 3 - 8 ) Install the NX-DPH/PAGING board on the middle of the base board.
Page 26
2INSTALL 1999.9.15 12:45 PM 페이지12 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 3.13.2 NX-820 SYSTEM ( See FIGURE 3-13) NX-820 system can have up to three expansion cards under the base board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS option boards are installed on the surface of Base board. NX-MPD or NX-PRS Board.
Page 28
2INSTALL 1999.9.15 12:45 PM 페이지16 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 50 PIN CHAMP CONNECTOR CLIP PIN NO. COLOR MDFB-C FUNCTION BL-W R1 1 C.O.1 CLIP 1 W-BL R2 1 RING R1 2 C.O.2 R2 2 RING GN-W R1 3 C.O.3 W-GN R2 3...
Page 29
2INSTALL 1999.9.15 12:45 PM 페이지18 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 50 PIN CHAMP CONNECTOR PIN NO. COLOR CLIP 1 FUNCTION CLIP 2 FUNCTION BL-W R1 1 C.O.1 R1 1 STN5 W-BL R2 1 RING R2 1 R1 2 C.O.2 R1 2 STN5 R2 2...
Page 30
2INSTALL 1999.9.15 12:45 PM 페이지20 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 50 PIN CHAMP 2 TRK 4TRK 4KLI 4 SLI 8 KLI 8 SLI 4 OPX CONNECTOR PIN NO. COLOR M D F D - M FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION BL-W R1 1 C.O.1 TIP...
Page 32
SLI port of your choice. 6.1 CONNECTING KEYSET / AOM (FIGURE 6-1) The NX-308 system has seven hybrid ports and the NX-1232 system has eight hybrid ports.Either a keyset or a single-line telephone may be connected to a hybrid port.
Page 33
NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 6.2.1 NX-308 - Related Switch Location (FIGURE 6-3) To connect the single line telephone to the any station from #2 to #8 of basic KSU, the related DIP switches should be set as follows.
Page 36
2INSTALL 1999.9.15 12:45 PM 페이지32 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 7.3 DOORPHONE AND DOOR LOCK RELEASE (See FIGURE 7-3) System users have the capability of communicating with an optional door phone when the N X - D P H / P A G I N G board is installed. A maximum of two door phones may be installed per system.
Page 37
2INSTALL 1999.9.15 12:45 PM 페이지34 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM R-MMC (9 PIN) (9 PIN) RXD 2 2 RXD TXD 3 3 TXD DTR 4 4 DTR SGND 5 5 SGND CTS 8 NOTE : If the CTS pin is not connected, the system cannot check the printer (MODEM) status (power ON/OFF, paper empty, etc.) FIGURE 7-4 SMDR &...
Page 38
Test and remove the faulty card before continuing. If the LED still does not light, unplug the KSU and change power supplies or Base board. This in all probability will solve the problem. If it does not, contact Samsung Technical Support. 2 - 32...
Page 39
2INSTALL 1999.9.15 12:45 PM 페이지38 NX-SERIES INSTALLATION SECTION HYBRID KEY SYSTEM 9-3 HOW TO REMOVE THE HANDSET CORD FROM THE HANDSET Driver Insert the sharp-edged one (ex:driver, pincette,...) into the slight gap of handset. Line holder Slightly push the driver, and lift up the line holder from handset.
Page 40
3feature 1999.9.15 12:44 PM 페이지1 FEATURES SECTION...
Page 42
3feature 1999.9.15 12:44 PM 페이지3 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM TABLE OF CONTENTS FEATURES 1. FEATURE DESCRIPTIONS ......3-1 1.1 SYSTEM FEATURES .
Page 43
3feature 1999.9.15 12:44 PM 페이지4 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM NOTICE this manual describes stadard setting. Some features, MMC Codes and default data may be different from those shown depending on the country.
Page 44
3feature 1999.9.15 12:44 PM 페이지5 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM 1. FEATURE DESCRIPTION 1.1 SYSTEM FEATURES LIVE SYSTEM PROGRAMMING TECHNICIAN LEVEL ACCOUNT CODE (Voluntary) CUSTOMER LEVEL ALL CALL VOICE PAGE STATION LEVEL ATTENTION TONE MEET ME PAGE AND ANSWER AUTHORIZATION CODES (Voluntary) MESSAGE WAITING INDICATION AUTOMATIC HOLD...
Page 45
3feature 1999.9.15 12:44 PM 페이지6 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM ACCOUNT CODE (Voluntary) Station users may enter an account code of up to seven (7) digits before hanging up a call. This account code will appear in the last column of the SMDR for that call record.
Page 46
3feature 1999.9.15 12:44 PM 페이지7 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM BATTERY BACKUP (Memory Protection) In the event that power is lost to the system, all customer data contained in memory is backed up by a base board Ni/Cd battery sufficient for at least seven (7) days continuous loss of system power.
Page 47
MPD or PRS card on the Base board. This feature is not available on NX-308. The MPD card detects metering pulses provided by Central Exchange and determines the call cost by the number of metering pulses and pre-programmed unit cost.
Page 48
3feature 1999.9.15 12:44 PM 페이지9 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM CHAIN DIALING Station users may manually dial additional digits following a Speed-Dial call, or chain together as many Speed-Dial numbers as required. CLASS OF SERVICE System programming may assign any of six outgoing call restriction levels. Refer to the TOLL RESTRICTION feature.
Page 49
3feature 1999.9.15 12:44 PM 페이지10 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM DIRECT TRUNK SELECTION Any station can directly select a specific C.O. line by simply pressing the appropriate button to either originate or answer a call. DIRECTORY NAMES Each station and C.O. line may be assigned a unique directory name. MMC 14 STATION NAME MMC 44 TRUNK NAME DISTINCTIVE RINGING...
Page 50
3feature 1999.9.15 12:44 PM 페이지11 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM EXECUTIVE BARGE-IN (Override) The feature allows specially-programmed stations to override the automatic privacy of another station. Programming provides three options: No Barge-in, With Tone, and Without Tone. When programmed without tone, the barging-in keyset has its microphone muted.
Page 51
3feature 1999.9.15 12:44 PM 페이지12 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM line, trunk group, or Speed-Dial number whenever the station goes off-hook. A hot line delay time of 1 to 9 seconds can be programmed to allow sufficient time to make a different call. MMC 25 HOT/WARM LINE IN GROUP / OUT OF GROUP Individuals assigned to a station hunt group may temporarily remove their...
Page 52
3feature 1999.9.15 12:44 PM 페이지13 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM passcode, and can assign Customer level access to MMCs as needed. CUSTOMER LEVEL This level requires the Customer level passcode and allows access to MMCs assigned by the Technician level in MMC 90. MMC 90 CUSTOMER USE MMC STATION LEVEL All keysets can access MMCs 10 through 17 without using a passcode.
Page 53
3feature 1999.9.15 12:44 PM 페이지14 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM Automatic Night Service Automatic Night Service allows the system to automatically go into and out of Night Service according to system clock time. This feature can be overridden by the Night Service button. MMC 56 ASSIGN AUTO NIGHT TIME OFF PREMISES EXTENSION (OPX) A single-line (tip and ring) extension may be connected to telephone company...
Page 54
3feature 1999.9.15 12:44 PM 페이지15 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM PORT STATUS CHECK Users can view their port status on the LCD. Any one of sixteen (16) status items (IDLE, BUSY, CALLBACK, PROGRAM, etc) may be displayed. MMC 92 PORT STATUS POWER FAILURE TRANSFER In the event of commercial power loss, the first two outside lines can automatically connect to the last two single-line stations.
Page 55
3feature 1999.9.15 12:44 PM 페이지16 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM database from a remote location via a customer-provided modem to make programming changes and view traffic reports as a troubleshooting aid. A customer PC can also be connected directly to the Base board for on-site programming. MMC 80 IO PARAMETER RING OVER PAGE A system-generated ring tone can be programmed on a per-line basis to signal...
Page 56
3feature 1999.9.15 12:45 PM 페이지17 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM STATION HUNT GROUPS System programming allows for up to 20 station groups. Four ring patterns are available for each group: SEQUENTIAL, DISTRIBUTE, CONDITION and UNCONDITION. Each group may contain a maximum 8 stations, and a station may be associated with only one group at a time.
Page 57
3feature 1999.9.15 12:45 PM 페이지18 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM TOLL RESTRICTION There are 250 allow and 250 deny entries of 11 digits each. Each of these entries can apply to dialing classes B, C, D and E. Class A stations have no dialing restrictions and class F stations cannot make outside calls.
Page 58
3feature 1999.9.15 12:45 PM 페이지19 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM at the end of each day or week. The report can also be printed on demand. A customer-provided printer must be connected to the SMDR or R-MMC port in order to print this report.
Page 59
3feature 1999.9.15 12:45 PM 페이지20 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM 1.2 STATION FEATURES ADD-ON MODULE (AOM) MUTE MICROPHONE / HANDSET APPOINTMENT REMINDER OFF-HOOK RINGING AUTOMATIC HOLD ON-HOOK DIALING AUTOMATIC PRIVACY ONE TOUCH DIALING KEYS BACKGROUND MUSIC PROGRAMMABLE KEYS BUSY STATION CALLBACK PROTECTION FROM BARGE-IN BUSY STATION INDICATION (BLF) PULLOUT DIRECTORY TRAY...
Page 60
3feature 1999.9.15 12:45 PM 페이지21 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM AUTOMATIC PRIVACY All conversations on outside lines and intercom calls are automatically private. The privacy feature can be turned off on a per-line basis. BACKGROUND MUSIC While the keyset is on-hook, the HOLD button alternately turns background music (BGM) on or off.
Page 61
3feature 1999.9.15 12:45 PM 페이지22 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM EXECUTIVE / SECRETARY HOT LINES A hands-free communication link is established when the EXECUTIVE/SECRETARY button is pressed. When the EXECUTIVE is in DND mode, all calls are forwarded to the SECRETARY and only the SECRETARY can call the EXECUTIVE.
Page 62
3feature 1999.9.15 12:45 PM 페이지23 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM LINE QUEUING WITH CALLBACK When the desired outside line is busy, the user can press the CALLBACK key or dial the access code to place his/her station in the queue awaiting that particular line.
Page 63
3feature 1999.9.15 12:45 PM 페이지24 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM the feature key applies to. MMC 72 STATION KEY PROGRAMMING PROTECTION FROM BARGE-IN Each station can be programmed as either secure or not secure. Secure stations cannot be barged-in on. A not secure station talking to a secure station cannot be barged-in on.
Page 64
3feature 1999.9.15 12:45 PM 페이지25 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM through the speaker. Ring Mode Calls are answered by pressing the SPEAKER button or by lifting the handset. Auto Answer Mode The keyset will automatically answer calls via the speakerphone. Voice Announce Mode Keyset users can hear the caller's voice, but caller cannot hear the user.
Page 65
3feature 1999.9.15 12:45 PM 페이지26 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM VACANT STATION MESSAGES Any keyset may select one of twenty messages to be displayed at a calling party's keyset. Ten messages are fixed, and the remaining ten can be customized by the system administrator (16 character maximum).
Page 66
3feature 1999.9.15 12:45 PM 페이지27 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM CALL FOR GROUP IDENTIFICATION When a call is made to a station group, the display will show the called group number. These calls can be answered with a different greeting than calls to the user's extension number.
Page 67
3feature 1999.9.15 12:45 PM 페이지28 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM IDENTIFICATION OF RECALLS Hold and Transfer recalls are identified differently. Hold recalls show [HOLD RECALL 203] and Transfer recalls show [RECALL FROM 204]. IDENTIFICATION OF TRANSFERS The display identifies who has transferred a call to the user [TRSF. FROM 206] and also shows when a call is camped-on to the user's station.
Page 68
3feature 1999.9.15 12:45 PM 페이지29 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM 2. FEATURE ID TABLE FEATURE FEATURE ID Operator Group Hold Pickup Pickup Page Hold 10 + Station / Trunk number Direct Pickup Hold H/F + 11 Call Secretary Call Boss 12 + 1 / 2 Open Doorphone H/F + 1...
Page 69
3feature 1999.9.15 12:45 PM 페이지30 NX-SERIES FEATURES SECTION HYBRID KEY SYSTEM < Sample SMDR printout > For more detailed SMDR information refer to Page 3-13, STATION MESSAGE DETAIL RECORDING(SMDR). SMDR REPORT FOR [ ] 01/08/96 15:19 ============================================================================ EXT TRK MM:DD STT.TIME DURATION NUMBER DIALED...
Page 72
4Programming 1999.9.15 12:42 PM 페이지3 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM TABLE OF CONTENTS PROGRAMMING 1. INTRODUCTION TO PROGRAMMING ........ 4-1 1.1 PROGRAMMING OVERVIEW ........... 4-1 1.2 PROGRAMMING LEVELS ............4-1 1.3 PROGRAM KEYS ..............4-2 1.3.1 NX keyset with LCD ................4-2 1.3.2 Other LCD keysets ................
Page 73
4Programming 1999.9.15 12:42 PM 페이지4 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM NOTICE this manual describes stadard setting. Some MMC Codes and default data may be different from those shown depending on the country.
Page 74
4Programming 1999.9.15 12:42 PM 페이지5 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM 1. INTRODUCTION TO PROGRAMMING 1.1 PROGRAMMING OVERVIEW The system arrives from the factory with default data entered. Connect it to trunks, stations, and power, turn the system on and it is fully operational. The only thing left to do is customize the data to fit the customer's needs.
Page 75
4Programming 1999.9.15 12:42 PM 페이지6 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM 1.3 PROGRAM KEYS 1.3.1 NX-keyset with LCD 1X16 LCD Display P r o g r a m m a b l e Butterns KEYPAD Used to enter data VOLUME (+) or (-) : Used to scroll through stations or trunks.
Page 76
4Programming 1999.9.15 12:42 PM 페이지7 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM 1.3.2 Other LCD keysets When the using other types of LCD keysets, such as the AS-30 or 816, programming key assignments will differ from the NX model, as shown in the box below.
Page 77
4Programming 1999.9.15 12:42 PM 페이지8 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM 2. PROGRAMMING PROCEDURES 2.1 PROGRAM LIST IN NUMERICAL ORDER STATION LOCK TRUNK GROUP 01: CHANGE STATION PASSCODE ASSIGN DISA LINE SET ANSWER MODE SYSTEM TIMERS CALL FORWARD TONE/RING CADENCE STATION ON/OFF SYSTEM WIDE COUNTER SET RING FREQUENCY...
Page 78
4Programming 1999.9.15 12:42 PM 페이지9 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM 2.2 PROGRAM LIST IN ALPHABETICAL ORDER ALARM REMINDER LANGUAGE SELECTION ASSIGN ADD-ON MODULE MAKE/BREAK RATIO ASSIGN AUTO NIGHT TIME OPEN PROGRAMMING ASSIGN BARGE-IN OVERRIDE TABLE ASSIGN BOSS/SECRETARY PAGE ZONE ASSIGN DISA LINE PBX ACCESS CODE ASSIGN DOOR RING...
Page 79
4Programming 1999.9.15 12:42 PM 페이지10 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM 2.3 PROGRAM PROCEDURES The following instructions for each MMC assume that you have already opened programming. To open SYSTEM (CUSTOMER) PROGRAMMING: Technician Passcode (default:4321) Customer Passcode (default:1234) When finished programming MMCs 00 through 95 and have other programming to do, press [SPEAKER] to exit the MMC and stay in the programming mode.
Page 80
4Programming 1999.9.15 12:42 PM 페이지11 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 00 STATION LOCK Use this MMC to lock or unlock stations in order to control others using your station. UNLOCK Normal status LOCKED1 Prohibit another user from making outside call. LOCKED2 Prohibit another user from dialing or receiving any calls.
Page 81
4Programming 1999.9.15 12:42 PM 페이지12 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 01 CHANGE STATION PASSCODE This MMC is used to reset any keyset's passcode to its default value of '1234',and cannot display station passcodes. Keyset users can set or change their individual passcodes, which are used to lock or unlock the keyset and to access the WALKING CLASS of service and DISA calls.
Page 82
4Programming 1999.9.15 12:42 PM 페이지13 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 10 SET ANSWER MODE This MMC is used to change the answer mode of any station to one of the following options: 1 RING The keyset will ring. Calls are answered by pressing [SPEAKER], or by lifting the handset.
Page 83
4Programming 1999.9.15 12:42 PM 페이지14 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 11 CALL FORWARD This MMC is used to program the call forwarding destination for each station and to set the time for FORWARD NO ANSWER. Each station can forward calls under the following condition. FORWARD ALL All calls are forwarded to destination station FORWARD BUSY...
Page 84
4Programming 1999.9.15 12:42 PM 페이지15 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 12 STATION ON/OFF This MMC allows the keyset user to set the following features: AUTO HOLD Places an existing C.O. call on hold if another trunk key (C.O. button) is pressed during that call.
Page 85
4Programming 1999.9.15 12:42 PM 페이지16 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 13 SET RING FREQUENCY This MMC is used to select the ring frequency at each keyset. There are four types of ring frequency available at each keyset. A sample of the selection can be heard when a dial key pad is pressed.
Page 86
4Programming 1999.9.15 12:42 PM 페이지17 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 14 STATION NAMES This MMC is used to enter a name of up to twelve (12) characters to identify an individual station. Names are entered via the keypad. Each press of a key will select a character. Pressing a different key will advance the cursor to the next position.
Page 87
4Programming 1999.9.15 12:42 PM 페이지18 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 15 DATA DISPLAY This MMC is used to change date display mode of each stations. Following date display mode are available. NOTE: AS-30S and SKP-816 model keysets display Western format only. 24 WESTERN WED 21 JUN 17:37 12 WESTERN...
Page 88
4Programming 1999.9.15 12:42 PM 페이지19 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 16 KEY EXTENDER This MMC is used to view the programmable keys assigned to a keyset station. It also allows the system administrator to assign key extenders to some keys to make a feature key more specific.
Page 89
4Programming 1999.9.15 12:42 PM 페이지20 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 17 STATION SPEED-DIAL This MMC is used to program the personal dial memory assigned to a station. Each station may have up to 20 memory locations, numbered 00 to 19. Each dial number consists of a trunk or trunk group access code followed by a separator ( : ) and up to 30 digits to be dialed.
Page 90
4Programming 1999.9.15 12:42 PM 페이지21 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 20 OPEN PROGRAMMING This MMC is used to open or close Customer or Technician level programming. If programming is not opened and an attempt is made to access a system MMC, the error message [NOT PERMIT] will be displayed.
Page 91
4Programming 1999.9.15 12:42 PM 페이지22 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 21 CHANGE PASSCODE Use this MMC to change the passcode allowing access to MMC 20 'Open Programming'. NOTE: The passcode is four digits long. A digit may be 0 to 9. The current (old) passcode is required for this MMC.
Page 92
4Programming 1999.9.15 12:42 PM 페이지23 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 22 CUSTOMER ON/OFF This MMC is used to allow the system administrator to set any of the following keyset features: When ON, allows the user to hear background music. When ON, allows the user to set the Do Not Disturb feature.
Page 93
4Programming 1999.9.15 12:42 PM 페이지24 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 23 PAGE ZONE This MMC is used to assign a keyset to one (or none) of the four internal paging zones. NOTE: Number 5 is external paging and ' ' assigns to all internal and external paging zones.
Page 94
4Programming 1999.9.15 12:42 PM 페이지25 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 24 ASSIGN BARGE-IN This MMC is used to set the type of barge-in permitted at a particular station. After the barge-in type is set, the barge-in class can be set. The barge-in class allows or disallows the user to barge-in on another station.
Page 95
4Programming 1999.9.15 12:42 PM 페이지26 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 25 HOT/WARM LINE This MMC is used to assign a hot line/prime line destination to a station. The destination may be any of the following: Station Number Station Group Number Trunk Number Trunk Group Number Speed-Dial location (00 to 99)
Page 96
4Programming 1999.9.15 12:42 PM 페이지27 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 26 ALARM REMINDER This MMC allows the system administrator or technician to set or change the alarm clock/appointment reminder feature for any station. Three alarms may be set for each station, and each alarm may be defined as a "DAY"...
Page 97
4Programming 1999.9.15 12:42 PM 페이지28 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 27 VACANT MESSAGE The system provides up to 20 vacant messages that can be selected by any display keyset user. Messages 01 through 10 are pre-programmed, as shown below. Messages 11 through 20 may be customized via this MMC.
Page 98
4Programming 1999.9.15 12:42 PM 페이지29 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 28 CALL DISC Used to assign the incoming and outgoing call disconnection per station. There are four different option. No Disconnection Out Only In Only Both PROCEDURE LCD DISPLAY 1.
Page 99
4Programming 1999.9.15 12:43 PM 페이지30 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 30 STATION TOLL CLASS This MMC is used to assign any of the 6 different day and/or night class of service to each station, as per the table below: DIAL DIGIT TOLL CLASS DESCRIPTIONS...
Page 100
4Programming 1999.9.15 12:43 PM 페이지31 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 31 EXT/TRK USE This MMC is used to allow trunks the ability to answer incoming calls, to dial out, or to do both, on a per-station basis. Those abilities are displayed as Y or N for each action (e.g.
Page 101
4Programming 1999.9.15 12:43 PM 페이지32 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 32 INTERCOM USE This MMC is used to allow/disallow station intercom calls. PROCEDURE LCD DISPLAY 1. Press [TRANSFER] and dial 32 2. Use [VOLUME (-) or (+)], to select a station (e.g. 202) To select all stations, press [VOLUME (-)] first 3.
Page 102
4Programming 1999.9.15 12:43 PM 페이지33 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 33 ASSIGN DOOR RING This MMC is used to designate which devices (station or station group) will ring when a door box button is pressed. PROCEDURE LCD DISPLAY 1.
Page 103
4Programming 1999.9.15 12:43 PM 페이지34 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 34 ASSIGN PICKUP GROUP This MMC is used to allow the assignment of stations to call pickup groups. There may be a maximum 10 pickup groups (0~9). An unlimited number of members can belong to each group.
Page 104
4Programming 1999.9.15 12:43 PM 페이지35 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 35 ASSIGN STATION GROUP This MMC is used to assign members of a station group. There are several options that can be selected for ringing, overflow, group transfer and overflow destination, and group type.
Page 105
4Programming 1999.9.15 12:43 PM 페이지36 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 35 4d. To assign the overflow port, enter the station or station group number. 4e. Press [MUTE] or [MESSAGE] to select the station group type Using KEYPAD, 1 for NORMAL GROUP 2 for VMAA GROUP 4f.
Page 106
4Programming 1999.9.15 12:43 PM 페이지37 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 36 ASSIGN BOSS/SECRETARY This MMC is used to assign BOSS keysets to SECRETARY keysets. One SECRETARY station may include two (2) BOSS stations. PROCEDURE LCD DISPLAY 1. Press [TRANSFER] and dial 36 2.
Page 107
4Programming 1999.9.15 12:43 PM 페이지38 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 37 ASSIGN ADD-ON MODULE This MMC is used to assign an add-on module (AOM) to a station. PROCEDURE LCD DISPLAY 1. Press [TRANSFER] and dial 37 Display shows the first AOM port If there is no AOM port, display shows: 2.
Page 108
4Programming 1999.9.15 12:43 PM 페이지39 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 38 SLT DIALING TYPE This MMC is used to define the dial type of phone connected to each SLT port. Keysets are not affected by this MMC. There are two dialing types: DIALING TYPES DTMF Dual Tone Multi-Frequency (Touch Tone)
Page 109
4Programming 1999.9.15 12:43 PM 페이지40 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 39 DATA LINE Used to assign SLT ports to be used for data transmission. VOICE - The station will be used for voice communication. All intrusion and warning tones will be heard during conversation. DATA - The station will be used for data communication.
Page 110
4Programming 1999.9.15 12:43 PM 페이지41 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 40 C.O./PBX LINE This MMC is used to select the mode of the C.O. line. If the PBX mode is chosen, the PBX access code can be recognized allowing more complete toll restrictions. This mode is assigned on a per-trunk basis.
Page 111
4Programming 1999.9.15 12:43 PM 페이지42 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 41 TRUNK DIALING TYPE This MMC is used to set the dial type of each C.O. line. There are two options: DTMF : Dual Tone Multi Frequency (Touch Tone) PULSE : Pulse dial (rotary).
Page 112
4Programming 1999.9.15 12:43 PM 페이지43 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 42 TRUNK ON/OFF This MMC is used to assign trunk options on a per-trunk basis. OPTION DESCRIPTION 1A2 EMULATION Trunk override call TRUNK FORWARD Allow trunk to be forwarded RING OVER PAGE Allow ring over external page TOLL CHECK FREE...
Page 113
4Programming 1999.9.15 12:43 PM 페이지44 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 43 ASSIGN TRUNK RING A trunk may have a maximum 16 members(station or station group) assigned to ring. PROCEDURE LCD DISPLAY 1. Press [TRANSFER] and dial 43 2. Using [VOLUME (-) or (+)], select the trunk you want (e.g., 703) 3.
Page 114
4Programming 1999.9.15 12:43 PM 페이지45 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 44 TRUNK NAMES This MMC is used to assign a name of up to twelve (12) characters to identify a particular trunk. Names are written using the keypad. Each press of a key will select a character. Pressing a different key moves the cursor to the next position.
Page 115
4Programming 1999.9.15 12:43 PM 페이지46 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 45 TRUNK GROUP This MMC is used to set the free trunk selection type to a specific trunk, trunk group, or to several trunk groups. There are eleven (11) trunk groups: 9 and 80 through 89, and three types of selecting a free trunk line in the group.
Page 116
4Programming 1999.9.15 12:43 PM 페이지47 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 46 ASSIGN DISA LINE This MMC is used to allow the system the ability to have Direct Inward System Access (DISA). There are four 4 DISA. If a trunk is set to DISA, the voice announcement feature may be used when the VOICE MSG option is enabled in MMC 42 TRUNK ON/OFF.
Page 117
4Programming 1999.9.15 12:43 PM 페이지48 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 50 SYSTEM TIMERS This MMC is used to adjust individual timers as necessary. All available timers are described in the TABLE OF TIMERS AND VALUES. NOTE: Seconds are shown as 'SEC', milliseconds as 'MS', and minutes as 'MIN'. PROCEDURE LCD DISPLAY 1.
Page 118
4Programming 1999.9.15 12:43 PM 페이지49 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 50 DISPLAY DESCRIPTION D E F A U L T RANGE DOR R OFF controls the duration of ringing at the door 030SEC 1~250SEC (Door Ring ring destination before canceling OFF time) FIRST DGT controls how long the system will wait for...
Page 119
4Programming 1999.9.15 12:43 PM 페이지50 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 51 TONE/RING CADENCE This MMC is used to customize the tone cadence on a system-wide basis to any one of the eight available selections. Call Technical Support before changing any cadences, as some systems may require default settings.
Page 120
4Programming 1999.9.15 12:43 PM 페이지51 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 52 SYSTEM WIDE COUNTER This MMC is used to set the values of the system counters. The counters and descriptions are listed below: OPTIONS DESCRIPTION ALM COUNTER This is the number of times (1 to 99) that an alarm (ALARM REMINDER reminder will ring a station before canceling.
Page 121
4Programming 1999.9.15 12:43 PM 페이지52 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 53 TRUNK WIDE TIMER This MMC is used to changed trunk timer values. It is not advisable to change these values, with exception of trunk flash time, without assistance from Technical Support. The available options are and listed below: DISPLAY DESCRIPTION...
Page 122
4Programming 1999.9.15 12:43 PM 페이지53 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 54 MAKE/BREAK RATIO This MMC is used to allow the ability to change the duration of the make/break time of pulse (rotary) dial trunks. PROCEDURE LCD DISPLAY 1. Press [TRANSFER] and dial 54 2.
Page 123
4Programming 1999.9.15 12:43 PM 페이지54 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 56 ASSIGN AUTO NIGHT TIME This MMC is used to automatically place the system in Night mode. A Night key is not needed, as the system switches automatically, but it is helpful to have a dedicated button so the status can be changed manually.
Page 124
4Programming 1999.9.15 12:43 PM 페이지55 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 57 CALL COST This MMC is used to program the unit cost of the metering pulse generated by the Central Office. If the MPD card is installed, it will detect the metering pulse provided by Central Exchange and determine the call cost by the number of metering pulses and unit cost programmed via this MMC.
Page 125
4Programming 1999.9.15 12:43 PM 페이지56 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 61 TOLL ALLOW TABLE/APPLY This MMC enables you to define which leading digit(s) in a dialing plan are to be allowed and which class(es) should be applied in this allow table. Each entry can define up to 11 digits.
Page 126
4Programming 1999.9.15 12:43 PM 페이지57 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 63 AUTHORIZATION TABLE This MMC is used to list all allowable authorization codes. An authorization code must be four digits long. There are 50 codes allowed in this table. Duplications or number conflicts are not permitted.
Page 127
4Programming 1999.9.15 12:43 PM 페이지58 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 64 OVERRIDE TABLE This MMC is used to enter up to five exceptions to toll restriction. These exceptions can be accessed by any class in both Day and Night modes, and are useful to allow access to emergency numbers.
Page 128
4Programming 1999.9.15 12:43 PM 페이지59 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 65 ASSIGN WILD CHARACTER Provides flexibility to toll restriction when a specific numbering plan is desired. There are only three entry tables, but more than one digit can be assigned per table if necessary. PROCEDURE LCD DISPLAY 1.
Page 129
4Programming 1999.9.15 12:43 PM 페이지60 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 66 SYSTEM SPD-DIAL TOLL RESTRICTION Enables you to define whether the system allows or denies long distance numbers in system Speed-Dialing to override toll restriction. BYPASS TOLL Any station can use system speed dial numbers without restriction, regardless of class FOLLOW TOLL The system checks all the system Speed-Dialings according...
Page 130
4Programming 1999.9.15 12:43 PM 페이지61 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 67 ASSIGN SYSTEM SPEED-DIAL This MMC is used to store up to eighty (80) system Speed-Dial numbers. The system Speed-Dial number is composed of 2 digits (20 to 99) and a maximum 30-digit telephone number can be stored at each Speed-Dial number.
Page 131
4Programming 1999.9.15 12:44 PM 페이지62 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 70 DIAL NUMBERING PLAN This MMC provides the access codes and dialing plan needed for operation of features and programs. The system comes with a wide range of acceptable numbering plans set as default, and the option to customize the dialing plan.
Page 133
4Programming 1999.9.15 12:44 PM 페이지64 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 71 SYSTEM KEY PROGRAMMING This MMC allows for the customizing of programmable keys system-wide. PROCEDURE LCD DISPLAY 1. Press [TRANSFER] and dial 71 2. Using [VOLUME (-) or (+)], select the type of keyset There are 7 keyset types: NX 24, NX 12, NX 6, SKP 816, AS 30, AS 12S, NX AOM.
Page 135
4Programming 1999.9.15 12:44 PM 페이지66 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 72 STATION KEY PROGRAMMING This program allows customizing programmable keys on specific electonic keysets on the system. The program also provides a tool for duplicating data to other keysets to have the same key format structure.
Page 136
4Programming 1999.9.15 12:44 PM 페이지67 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 73 KEY TEST This program allows you to check whether each key works properly. PROCEDURE LCD DISPLAY 1. Press [TRANSFER] and dial 73 ▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩ All LEDs light and station rings. Display sets show the full matrix pattern for 16 characters.
Page 137
4Programming 1999.9.15 12:44 PM 페이지68 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 80 SYSTEM I/O PARAMETERS This MMC provides a means of setting parameters for the serial I/O ports to work with SMDR and Remote MMC. Programming is accomplished easily with the tables below to customize either I/O port. PARAMETER OPTIONS TYPE OF SERVICE...
Page 138
4Programming 1999.9.15 12:44 PM 페이지69 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 81 SMDR OPTIONS This MMC allows the system administrator to select information to be printed on the SMDR report. OPTIONS DESCRIPTIONS PAGE HEADER This option determines whether a page header will print at the top of each page.
Page 139
4Programming 1999.9.15 12:44 PM 페이지70 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 83 CALL TRAFFIC REPORT This MMC is used to print a traffic report and select options. Four types of printing are available, each with has two options. These are listed below: TYPE DESCRIPTION No print...
Page 140
4Programming 1999.9.15 12:44 PM 페이지71 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 90 CUSTOMER USE MMC Allows the station user access to certain MMCs. For example, it is advised that the user have access to MMC11 Call Forward, but not MMC60 Toll Deny. PROCEDURE LCD DISPLAY 1.
Page 141
4Programming 1999.9.15 12:44 PM 페이지72 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 91 SYSTEM VERSION This MMC provides display of the current software version of the KSU and the KEYSET, and the date the product was made. This is a READ ONLY MMC. PROCEDURE LCD DISPLAY 1.
Page 142
4Programming 1999.9.15 12:44 PM 페이지73 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 93 LANGUAGE SELECTION Used to select one of three (3) languages to display in keyset LCDs. Choose an entry number from the table below: ENTRY NUMBER LANGUAGE ENGLISH SPANISH PORTUGUESE NOTE : English is displayed while in MMC mode.
Page 143
4Programming 1999.9.15 12:44 PM 페이지74 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 94 HALT PROCESS Use only in the event that all data processing must be stopped. The four-digit Technician Passcode is required to access this MMC. This MMC will not interfere with any call in progress, but attempting a new call will result in a busy tone.
Page 144
4Programming 1999.9.15 12:44 PM 페이지75 NX-SERIES PROGRAMMING SECTION HYBRID KEY SYSTEM MMC 95 SYSTEM RESTART Provides two methods of restarting the system. OPTIONS DESCRIPTION RESET SYSTEM Restart the system only. CLEAR MEMORY Restart the system and clear all memory and set all functions to their default values.
Page 148
5APPENDIX 1999.9.15 12:41 PM 페이지3 NX-SERIES APPENDIX A REMOTE PROGRAMMING HYBRID KEY SYSTEM APPENDIX A REMOTE PROGRAMMING Remote programming capability has been incorporated in the NX-SERIES via the R-MMC serial port on the SMDR/R-MMC board option mounted on the base unit. This port is configured as a programming port only.
Page 149
5APPENDIX 1999.9.15 12:41 PM 페이지4 NX-SERIES APPENDIX A REMOTE PROGRAMMING HYBRID KEY SYSTEM 1.3 BEGIN PROGRAMMING Dial the customer modem number and establish a communication link with the customer site. Once communication is established, press the TAB key on the PC keyboard to receive the NX-SERIES system header display (below).
Page 150
5APPENDIX 1999.9.15 12:41 PM 페이지5 NX-SERIES APPENDIX A REMOTE PROGRAMMING HYBRID KEY SYSTEM 2. ON-SITE PROGRAMMING VIA PC TERMINAL On-site programming via a PC terminal has been incorporated in the NX-SERIES via serial communication port R-MMC of the SMDR/R-MMC board mounted on the Base board.
Page 151
5APPENDIX 1999.9.15 12:41 PM 페이지6 NX-SERIES APPENDIX A REMOTE PROGRAMMING HYBRID KEY SYSTEM open programming and begin the on-site programming session. NOTE: The header will display CUSTOMER and the name assigned in MMC 81. 2.3 PROGRAMMING PROTOCOL The NX-SERIES will only recognize keystrokes on the PC keyboard that have been assigned as NX 24 keyset equivalent.
Page 152
5APPENDIX 1999.9.15 12:41 PM 페이지7 NX-SERIES APPENDIX B DATABASE DOWNLOAD HYBRID KEY SYSTEM APPENDIX B DATABASE DOWNLOAD 1. Introduction To Database Download Programming A database download programming capability has been incorporated into the N X - S E R I E S via the communication (serial) SMDR port of the optional S M D R / R - M M C card mounted in the base unit.
Page 153
5APPENDIX 1999.9.15 12:41 PM 페이지8 NX-SERIES APPENDIX B DATABASE DOWNLOAD HYBRID KEY SYSTEM 3) Enter the DATABASE DOWNLOAD directory. 4) Double-click on the icon that was created by the install program in the Windows -"NX_DOWN" 5) You will see Windows shown below. Figure 1.1 Main Window 3.
Page 154
5APPENDIX 1999.9.15 12:41 PM 페이지9 NX-SERIES APPENDIX B DATABASE DOWNLOAD HYBRID KEY SYSTEM 6) Choose Download / Serial Port*** 7) Check COM port in the Select serial port check box 8) Select OK button. Figure 1.3 Port dialog box 4. Using database downloading program 4.1 Downloading 1) Choose DOWNLOAD / Download to File***.
Page 155
5APPENDIX 1999.9.15 12:41 PM 페이지10 NX-SERIES APPENDIX B DATABASE DOWNLOAD HYBRID KEY SYSTEM Figure 1.6 MMC page tab 4.3 Save file This option saves the downloaded file with another name with the save file option. 4.4 Print file This option prints the database file that you downloaded 4.5 Help This option shows the program version 5 - 8...
Page 156
5APPENDIX 1999.9.15 12:41 PM 페이지11 NX-SERIES APPENDIX C DISA VOICE ANOUNCEMENT HYBRID KEY SYSTEM APPENDIX C DISA VOICE ANOUNCEMENT 1. DISA AUTOMATIC ANSWER The system answers automatically an incoming DISA (Direct Inward System Access) call and sends the message: "This is XXX company. Extension number, please". This facilitates handling your DISA calls and tells the calling party the status of the called extension via recorded voice message phrase 2 or 3.
Page 157
5APPENDIX 1999.9.15 12:41 PM 페이지12 NX-SERIES APPENDIX C DISA VOICE ANOUNCEMENT HYBRID KEY SYSTEM ● Start to record through handset or speaker phone. ● After recording, you can hear automatically the recorded message. NOTE ● In case of first Power on, record phrase 1 to phrase 4 in sequence. 3.3 Monitoring ●...
Page 158
6BACK_UP 1999.9.15 12:40 PM 페이지1 BACK-UP DATA SHEETS...
Page 162
6BACK_UP 1999.9.15 12:40 PM 페이지5 SYSTEM CONFIGURATION SYSTEM EXPANSION Bd. STATION DATA STATION LOCK ANSWER STATION ON / OFF (12) NAME TOLL (00) MODE (10) (14) CLASS AUTO AUTO HEADSET HOT RING (30) HOLD TIMER KEYPAD TONE FREQ. COPY AS NEEDED SHEET _____ OF_______...
Page 163
6BACK_UP 1999.9.15 12:40 PM 페이지6 MMC 11 CALL FORWARD STATION DESTINATION NO ANSWER TIME FORWARD ALL FORWARD BUSY FORWARD NO ANSWER MMC 17 STATION SPEED-DIAL STATION NO. ENTRY NO. SPEED-DIAL NO. MMC 21 CHANGE PASSCODE PASSCODE MMC 22 CUSTOMER ON/OFF STATION DOOR HUNT...
Page 164
6BACK_UP 1999.9.15 12:40 PM 페이지7 MMC 24 BARGE-IN OPTION STATION NO. BARGE-IN CLASS MMC 25 HOT / WARM LINE STATION NO. DESTINATION WARM LINE DELAY TIME MMC 26 ALARM REMINDER STATION NO. ALARM NO. ALARM TIME DAY/DALY MMC 27 VACANT MESSAGE MESSAGE NO.
Page 165
6BACK_UP 1999.9.15 12:40 PM 페이지8 MMC 32 INTERCOM USE STATION NO. DESTINATION STATION MMC 33 ASSIGN DOOR RING DOOR NO. NIGHT MMC 34 PICKUP GROUP GROUP NO. MEMBER ID STATION NO. PICKUP GROUP NO. : MAXIMUM NUMBER OF PICKUP GROUPS IS 10. MMC 35 STATION GROUP STATION GROUP NO.
Page 166
6BACK_UP 1999.9.15 12:40 PM 페이지9 MMC 37 ADD-ON MODULE MASTER MASTER MASTER MMC 38 SLT DIALING TYPE STATION NO. TYPE STATION NO. TYPE MMC 39 DATA LINE STATION NO. VOICE / DATA STATION NO. VOICE / DATA MMC 40 C.O. PBX LINE TRUNK NO.
Page 167
6BACK_UP 1999.9.15 12:40 PM 페이지10 MMC 45 TRUNK GROUP MODE GROUP NO. : MEMBER MAXIMUM NUMBER OF TRUNK GROUPS IS 11. MMC 46 ASSIGN DISA LINE TRUNK NO. DISA OPTION VOICE MSG (42) MMC 50 SYSTEM TIMERS TIMER RANGE DEFAULT ALM R INT 1~250 sec 025 sec...
Page 168
6BACK_UP 1999.9.15 12:41 PM 페이지11 SMDR PULAS 1~250 sec 030 sec SMDR DRMF 0~250 sec 015 sec TRK DISC 1~250 min 030 min MMC 51 TONE / RING CADENCE TONE/RING MMC 52 SYSTEM WIDE COUNTER OPTION COUNTER MMC 53 TRUNK WIDE TIMER TIMER RANGE DEFAULT...
Page 170
6BACK_UP 1999.9.15 12:41 PM 페이지13 MMC 63 AUTHORIZATION CODE CODE CLASS CODE CLASS MMC 64 OVERRIDE TABLE CODE CODE CODE MMC 65 WILD CHARACTER MMC 67 ASSIGN SYSTEM SPEED-DIAL SPEED DIAL NO. SPEED-DIAL NO. MMC 70 DIAL NUMBERING PLAN ENTRY ACCESS CODE ENTRY ACCESS CODE...
Page 171
6BACK_UP 1999.9.15 12:41 PM 페이지14 AS-30 SKP-816 NX-AOM MMC 80 IO PARAMETERS COM1 COM2 XON OFF SMDR REMOTE TRAFFIC COM1 COM2 PORT MMC 81 SMDR OPTIONS PAGE LINE PER INCOMING AUTHORX LESS START ALARM COMPANYN H E A D E R PAGE CALL E CODE...
Page 172
표지 1999.9.15 12:40 PM 페이지2 CODE: GA68-60655A Edition : 05 DN April 1999 Printed In Korea...