Startup Problems
After you install a Cisco IP Phone into your network and add it to Cisco Unified Communications Manager,
the phone should start up as described in the related topic below.
If the phone does not start up properly, see the following sections for troubleshooting information.
Related Topics
Verify Phone Startup, on page 40
Cisco IP Phone Does Not Go Through the Normal Startup Process
Problem
When you connect a Cisco IP Phone to the network port, the phone does not go through the normal startup
process as described in the related topic and the phone screen does not display information.
Cause
If the phone does not go through the startup process, the cause may be faulty cables, bad connections, network
outages, lack of power, or the phone may not be functional.
Solution
To determine whether the phone is functional, use the following suggestions to eliminate other potential
problems.
• Verify that the network port is functional:
• Verify that the phone is receiving power:
• If the phone still does not start up properly, power up the phone by pressing #*2. When the phone is
• If the phone still does not start up properly, perform a factory reset of the phone.
◦ Exchange the Ethernet cables with cables that you know are functional.
◦ Disconnect a functioning Cisco IP Phone from another port and connect it to this network port to
verify that the port is active.
◦ Connect the Cisco IP Phone that does not start up to a different network port that is known to be
good.
◦ Connect the Cisco IP Phone that does not start up directly to the port on the switch, eliminating
the patch panel connection in the office.
◦ If you are using external power, verify that the electrical outlet is functional.
◦ If you are using in-line power, use the external power supply instead.
◦ If you are using the external power supply, switch with a unit that you know to be functional.
powered up in this way, it attempts to launch a backup software image.
Cisco IP Phone 7800 Series Administration Guide for Cisco Unified Communications Manager
Startup Problems
207