The above conditions are proper.
4.3 Heat reserving test
1. Put approx. 1 liter of water and the thermometer [ repairing tool (mercury thermometer ASN-150H) ]
in the pan, close the lid and turn on the boiling switch.
2. When the beings boiling to generate steam turn off the boiling switch.
3. Add water or keep the lid opened until the reading of the thermometer falls to approx. 70°C.
4. When it becomes approx. 70°C, close the lid. After the warming heater is activated for 1 hour or more,
check the heat reserving temperature.
Within 69°C - 77°C .....................................Proper
If outside 69°C - 77°C, check triac mounting for irregularity, if it is proper, replace warming heater.
Urethane foam blocks
Top view of pan
Holes on the
tissue paper
Mercury thermometer
Pan flange
Tissue paper
Mercury thermometer
Inner Pan
- 10 -
SR-TML500 / SR-TML510 / SR-TMS520