2) Open the paper feed guide to the maximum width position.
3) Select MAX. POSITION using the numeric keypad.
4) Press the Start key.
The maximum width detection level is recognized.
5) Press the CUSTOM SETTINGS key.
6) Open the paper feed guide to the minimum width position.
7) Select MIN. POSITION using the numeric keypad.
8) Press the Start key.
The minimum width detection level is recognized.
Note: When each of the above operations has been completed, the
"COMPLETE" message appears; when any of the operations
has failed, the "ERROR" message appears.
ADJ 14C
Adjust the paper width sensor for the
SPF paper feed tray
This adjustment is needed in the following situations:
• The paper feed tray section has been disassembled.
• The paper feed tray unit has been replaced.
• U2 trouble has occurred.
• The scanner PWB has been replaced.
• The EEPROM on the scanner PWB has been replaced.
1) Go through the modes specified in Simulation 53-6.
AR-M550/M620/M700 SETTING AND ADJUSTMENTS 7 - 41
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
Select 1, and
press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX.POSITION ... COMPLETE (or "ERROR")
Select 2, and press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or "ERROR")
Select 3, and press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or "ERROR")
Select 4, and press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN.POSITION ... COMPLETE (or "ERROR")
2) Open the SPF paper feed guide to the maximum width position.
3) Select MAX. POSITION using the numeric keypad.
4) Press the Start key.
The maximum width detection level is recognized.
5) Press the CUSTOM SETTINGS key.
6) Open the SPF paper feed guide to the width for the A4R size.
7) Select POSITION 1 using the numeric keypad.
8) Press the Start key
The A4R width detection level is recognized.
9) Press the CUSTOM SETTINGS key.
10) Open the SPF paper feed guide to the width for the A5R size.
11) Select POSITION 2 using the numeric keypad.
12) Press the Start key.
The A5R width detection level is recognized.
13) Press the CUSTOM SETTINGS key.