Figure 10: Failsafe Alarm Relay Wiring
1. Normally Open
2. Common
Section 2.4

Grounding the Device

The M2200 chassis ground terminal uses a #6-32 screw. It is recommended to terminate the ground connection
with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in).
Figure 11: Chassis Ground Connection
1. Stainless Steel Stud
Section 2.5

Connecting to the Device

The following describes the various methods for accessing the ROS console and Web interfaces on the device.
For more detailed instructions, refer to the ROS User Guide for the M2200.
Grounding the Device
3. Normally Closed
2. #6-32 Screw
3. #6 Ring Lug
1
3
2
2
3
1
Chapter 2
Installing Device
13