hit counter script
Table of Contents

Advertisement

Xen IPK
P r o g ra m m i n g M a n ua l
NEC Business Solutions Ltd
Doc. No.: 8194
Release 2.0
December 2004

Advertisement

Table of Contents
loading

Summary of Contents for NEC Xen IPK

  • Page 1 Xen IPK P r o g ra m m i n g M a n ua l NEC Business Solutions Ltd Doc. No.: 8194 Release 2.0 December 2004...
  • Page 2 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK Programming Manual...
  • Page 3: Table Of Contents

    Table of Contents Chapter 1 Multiline Terminal Programming Section 1 General Information ..................1 - 1 Section 2 Programming the System................1 - 1 Section 3 System Data List ..................1 - 10 Section 4 Programming System Data ................. 1 - 29 1-1-00 Pause Time Selection.............
  • Page 4 December 2004 NEC Business Solutions Ltd 1-1-50 CO/PBX Outgoing Digit Add Assignment........1 - 85 1-1-51 CO Line Ringing Pattern Selection..........1 - 87 1-1-52 PBX Line Ringing Pattern Selection........1 - 89 1-1-53 Tie Line Delay Ring Pattern Selection........1 - 91 1-1-54 Automated Attendant Transfer Ring Pattern ......1 - 93...
  • Page 5 Xen IPK Programming Manual 1-2-25 Internal Paging Alert Tone Selection ........1 - 148 1-2-26 Delayed Ringing Timer Assignment (ICM) ......1 - 149 1-2-28 PS Out of Area Tone Selection..........1 - 150 1-2-30 PS Out of Area Timer Selection (BSU only) ......1 - 151 1-2-31 Call Pickup Group - Direct ...........
  • Page 6 December 2004 NEC Business Solutions Ltd 1-5-14 Printer Line Feed Control Selection ........1 - 193 1-5-23 Outgoing Mode Selection ............1 - 194 1-5-25 SMDR Valid Call Timer Assignment........1 - 195 1-5-26 SMDR Incoming/Outgoing Print Selection ......1 - 196 1-6-00 Attendant Add-On Console to Telephone Port Assignment .1 - 197 1-6-03 DSS Call Voice/Tone Signal Selection .........1 - 198...
  • Page 7 Xen IPK Programming Manual 1-8-49 New AA-Info Yes/No Selection ..........1 - 254 1-9-00 DISA/ID Code Assignment ..........1 - 255 1-9-02 DISA/ID Password Effect/Invalid Selection......1 - 256 1-9-03 ID Restriction Class Assignment (Day Mode)....... 1 - 257 1-9-04 ID Restriction Class Assignment (Night Mode).....
  • Page 8 December 2004 NEC Business Solutions Ltd 2-01 Trunk to Tenant Assignment ..........1 - 329 2-05 Line Key Selection..............1 - 331 2-06 Line Key Selection for Tenant Mode ........1 - 332 2-07 System Speed Dial Display Assignment .......1 - 335 2-08 ECR Relay to Tenant Assignment.........1 - 337...
  • Page 9 Xen IPK Programming Manual 3-61 DIT Delay Answer Timer Selection........1 - 390 3-62 DIT Tenant Assignment ............1 - 392 3-63 DIT Holiday Mode Enable............. 1 - 394 3-64 DIT Night Mode Delay Answer Enable ......... 1 - 395 3-65 Hold Tone Automated Attendant Selection ......
  • Page 10 December 2004 NEC Business Solutions Ltd 4-44 Caller ID/Preset Dial Outgoing CO Selection .......1 - 450 4-46 Live Record Auto Delete ............1 - 451 4-47 ISDN Directory Number Selection........1 - 452 4-49 Caller ID Display for CAR Key..........1 - 454 4-50 Multiline Terminal Type Selection ........1 - 455...
  • Page 11 Section 3 Software Installation.................. 3 - 600 Section 4 Wizard ....................... 3 - 600 Section 5 Programming Screens ................3 - 603 Section 6 Toolbar ...................... 3 - 605 Section 7 Xen IPK Pulldown Menus................3 - 607 Programming Manual...
  • Page 12 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK Table of Contents...
  • Page 13: General Information

    Section 2 Programming the System No figures for this section. Figure 1-1: Programming Flowchart ..........1 - 2 Figure 1-2: Xen IPK Multiline Terminal ..........1 - 5 Figure 1-3: Page Display for 16-Key and 24-Key Multiline Terminals.................1 - 8 Figure 1-4: Page Switching for Data Values ........1 - 9 Section 4 Programming System Data No figures for this section.
  • Page 14 December 2004 NEC Business Solutions Ltd Section 5 Programming Screens No figures for this section. Figure 3-4: Xen IPK Maintenance Access Terminal Software Screen Samples ............3 - 604 Section 6 Toolbar No figures for this section. Section 7 Xen IPK Pulldown Menus No figures for this section.
  • Page 15: List Of Tables

    No figures for this section. Section 4 Wizard No figures for this section. Section 5 Programming Screens No figures for this section. Section 6 Toolbar No figures for this section. Section 7 Xen IPK Pulldown Menus No figures for this section. Programming Manual...
  • Page 16 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK List of Tables...
  • Page 17: Chapter 1 Multiline Terminal Programming

    Preface About this manual. The Programming Manual was developed primarily for the technician and provides all necessary information for programming the Xen IPK system. Programming can be accomplished using either a PC or a Multiline Terminal. ECTION This manual provides instructions for programming the Xen system.
  • Page 18 December 2004 NEC Business Solutions Ltd Automatic Call Distribution Manual This manual provides service technician with instructions for programming the ACD. This manual can also be used by the ACD supervisor at the customer site to become familiar with the ACD/ MIS feature.
  • Page 19 Changes will be periodically made to the information in the new editions. Efforts have been made to ensure that the contents of this manual are correct. Should you find any error, NEC welcomes your comments to improve our communications. Please contact NEC on 1800 036 136.
  • Page 20 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK Disclaimer...
  • Page 21 Multiline Terminal Programming Chapter 1 SECTION 1 The Xen IPK system is a stored-program controlled system. When the system is initially powered up, the CPU scans each possible interface slot to GENERAL determine the hardware configuration. The system stores this information INFORMATION and the default values in the resident system program memory.
  • Page 22: Figure 1-1: Programming Flowchart

    December 2004 NEC Business Solutions Ltd Functions of an existing system are changed. New Installation Existing System Component Function Develop System Data Sheet Replacement Change Installation Rewrite System Rewrite System Data Sheet Data Sheet Test System with Installation Default Values...
  • Page 23: Programming Modes

    Xen IPK Programming Manual System Programming Modes System programming has eight modes and some modes have submodes. The modes and submodes are listed in Table 1-1: Programming Modes. Table 1-1: Programming Modes Line Line Mode Name Submode Name LK 1...
  • Page 24 December 2004 NEC Business Solutions Ltd Before Programming The technician should check the ROM version and the port numbers before programming the system. 2.3.1 Check Points Confirming the ROM Version The features that are available depend on the ROM version. Refer to Memory Block 8-1 (ROM Version Confirmation).
  • Page 25 2.5.2 Using the Multiline Terminal for Programming System programming can be performed using a display type Multiline Terminal that is connected to station ports 01 or 02. Refer to Figure 1-2: Xen IPK Multiline Terminal Display (LCD) Exit Key Message...
  • Page 26: Figure 1-2: Xen Ipk Multiline Terminal

    December 2004 NEC Business Solutions Ltd Figure 1-2: Xen IPK Multiline Terminal provides a list and description of the keys used during Multiline Terminal Programming. Description ∼ Used to enter data from the dial pad and to specify a Memory Block location.
  • Page 27 Xen IPK Programming Manual 2.5.3 Entering Programming Mode To program information in the system, the following digital Multiline Terminals can be used as programming stations. Two stations, ports 01 and 02, are automatically assigned as programming stations. DTU-16D-1A (BK)/(WH) TEL...
  • Page 28: Figure 1-3: Page Display For 16-Key And 24-Key Multiline Terminals

    December 2004 NEC Business Solutions Ltd To navigate between pages, use to access the next page and to return to the previous page. 16-Key Multiline Terminal 24-Key Multiline Terminal (Page 1) (Page 1) LK 1 LK 2 LK 3 LK 4...
  • Page 29: Figure 1-4: Page Switching For Data Values

    Figure 1-4: Page Switching for Data Values 2.5.5 Station Port Numbering Plan Some memory blocks require entering a 2-digit port number. The Xen IPK system supports 48/120 ports. Programming values for entry of Port Assignments are defined below: Port Assignments Programming Value...
  • Page 30: Section 3 System Data List

    December 2004 NEC Business Solutions Ltd SECTION 3 The following table provides a complete list of Memory Blocks that are available in the Xen system. The information is organised by mode, SYSTEM DATA LIST submode, and then numerically by Memory Block number. The Memory Block number and name, the default values, and programming values are provided for each Memory Block.
  • Page 31 Xen IPK Programming Manual LK 1 System Mode LK 1 CO Line (Continued) Data Memory Block Name Default Value Programming Values DID Digit Conversion Table Not Specified Ext. No. (Up to 4 digits) & DNIS Assignment DID Forward Station Number for Busy NON, Ext.
  • Page 32 December 2004 NEC Business Solutions Ltd LK 1 System Mode LK 1 CO Line (Continued) Data Memory Block Name Default Value Programming Values 8-Digit Matching Table to Class Refer to 8-Digit Matching Table Assignment on page 1-98. Assignment System Speed Dial Override...
  • Page 33 Xen IPK Programming Manual LK 1 System Mode LK 1 CO Line (Continued) Data Memory Block Name Default Value Programming Values Call Monitoring Alert Assignment LK 1 System Mode LK 2 ICM Data Memory Block Name Default Value Programming Values Internal Paging Timeout Selection 90 sec.
  • Page 34 December 2004 NEC Business Solutions Ltd LK 1 System Mode LK 2 ICM (Continued) Data Memory Block Name Default Value Programming Values Call Pickup Group - Direct All Blank 0~9 groups. 30 Tel per group max. LK 1 System Mode...
  • Page 35 Xen IPK Programming Manual LK 1 System Mode LK 4 Transfer/Automated Attendant (A.A.) Data Memory Block Name Default Value Programming Values Tandem Transfer Automatic Disconnect 1 hr. 30 min., 1 hr., 2 hr., 3 hr. Timer Selection Automated Attendant First Digit PBR 10 sec.
  • Page 36 December 2004 NEC Business Solutions Ltd LK 1 System Mode LK 4 Transfer/Automated Attendant (A.A.) (Continued) Data Memory Block Name Default Value Programming Values Automated Attendant Extension Number Not Specified Tel No. (Up to 4 digits) phantom number only Assignment...
  • Page 37 Xen IPK Programming Manual LK 1 System Mode LK 7 ESP Data Memory Block Name Default Value Programming Values Doorphone Assignment No (Not Assign)/Yes (Assign) Doorphone Display Time Selection 10 sec. 10 sec., 30 sec., 60 sec., 90 sec. External Speaker Connection Selection...
  • Page 38 December 2004 NEC Business Solutions Ltd LK 1 System Mode LK 8 PBR/Miscellaneous (Continued) Data Memory Block Name Default Value Programming Values VRS Message Function Assignment No Message No Message Voice Prompt 1~2 1st and 2nd Delay Announce Day Mode A.A. 1~8 Night Mode A.A.
  • Page 39 Xen IPK Programming Manual LK 1 System Mode LK 8 PBR/Miscellaneous (Continued) Data Memory Block Name Default Value Programming Values New AA-Info Yes/No Selection LK 1 System Mode LK 9 DISA Data Memory Block Name Default Value Programming Values DISA/ID Code Assignment Refer to DISA/ID Code Assignment on page 1-255.
  • Page 40 December 2004 NEC Business Solutions Ltd LK 1 System Mode LK 12 ACD/UCD Data Memory Block Name Default Value Programming Values ACD/UCD Group Pilot Number Not Specified Tel No. (Up to 4 digits) Assignment (for each ACD/UCD Group No. 1~4)
  • Page 41 Xen IPK Programming Manual LK 1 System Mode (Continued) LK 14 Automatic Route Selection Data Memory Block Name Default Value Programming Values ACR Digit Delete Assignment 00~10 Digits ACR Digit Add Assignment Not specified Up to 10 digits using 0~9, *, #...
  • Page 42 December 2004 NEC Business Solutions Ltd LK 1 System Mode (Continued) LK 15 ??? Data Memory Block Name Default Value Programming Values Centralised BLF Receive Extension Number Assignment LK 2 Tenant Mode Data Memory Block Name Default Value Programming Values Trunk to Tenant Assignment Refer to Trunk to Tenant Assignment on page 1-329.
  • Page 43 Xen IPK Programming Manual LK 3 CO/PBX Line Mode (Continued) Data Memory Block Name Default Value Programming Values Tie/DID Line Type Assignment Immediate Second Dial Tone Immediate Delayed Wink Start Trunk DTMF Duration/Interdigit Selection 60 ms/80 ms 60 ms. /70 ms.
  • Page 44 December 2004 NEC Business Solutions Ltd LK 3 CO/PBX Line Mode (Continued) Data Memory Block Name Default Value Programming Values Trunk Internal Transmit Pad Selection 2 dB 2 dB, 4 dB, 6 dB, 8 dB, 12 dB, 16 dB, 3 dB, -3...
  • Page 45 Xen IPK Programming Manual LK 3 CO/PBX Line Mode (Continued) Data Memory Block Name Default Value Programming Values ISDN BRT Connection Configuration Polarity Reverse Selection CO/PBX/DID/TLI = No Yes, No BRI/PRI = Yes Trunk Type Selection CTX Assume 9 Trunk (Installed, DP/DTMF) Selection...
  • Page 46 December 2004 NEC Business Solutions Ltd LK 4 Telephone Mode (Continued) Data Memory Block Name Default Value Programming Values Intercom Master Hunt Number Forward All Telephones Not Station Number (2, 3, 4 Digit) Assignment Specified Station to Class of Service Feature Refer to Station to Class of Service Feature Assignment on page 1-424.
  • Page 47 Xen IPK Programming Manual LK 4 Telephone Mode (Continued) Data Memory Block Name Default Value Programming Values ISDN Directory Number Selection Caller ID Display for CAR Key Not Specified Tel Port No. 01~120 Multiline Terminal Type Selection 16 Button Type...
  • Page 48 December 2004 NEC Business Solutions Ltd LK 5 Trunk Group Mode Data Memory Block Name Default Value Programming Values Digit Add/Del for Tie Line Networking No Add and Delete = 000 Delete up to two digits Add up to two digits...
  • Page 49: Section 4 Programming System Data

    December 2004 NEC Business Solutions Ltd LK 8 Special Mode Data Memory Block Name Default Value Programming Values ROM Version Confirmation Refer to ROM Version Confirmation on page 1-513. System Speed Dial Memory Clear Refer to System Speed Dial Memory Clear on page 1-515.
  • Page 50 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 30 – Chapter 1 Multiline Terminal Programming...
  • Page 51: Pause Time Selection

    Xen IPK Programming Manual 1-1-00 Pause Time Selection System Mode General Description Submode A pause can be inserted between digits dialled on CO/PBX and Tie lines. Use this Memory Block to specify the length of the pause. Data No. Display...
  • Page 52: Dp Interdigit Time Selection

    December 2004 NEC Business Solutions Ltd 1-1-01 DP Interdigit Time Selection System Mode General Description Submode The DP Interdigit Time is the minimum pause time interval between Dial Pulse dialling. Use this Memory Block to Select either Pattern A or Pattern B.
  • Page 53: Hookflash Time Selection

    Xen IPK Programming Manual 1-1-02 Hookflash Time Selection System Mode General Description Submode Use this Memory Block to specify the loop open time for a hookflash signal sent to the CO or PBX when the Recall key on a Multiline Terminal is pressed. A Single Line Telephone (SLT) Data No.
  • Page 54: Hold Recall Timer Selection (Non Exclusive Hold)

    December 2004 NEC Business Solutions Ltd 1-1-03 Hold Recall Timer Selection System Mode (Non Exclusive Hold) Submode General Description Data No. Use this Memory Block to specify the time a Non-Exclusive Hold outside call is held until a recall tone is generated. If No Limit is selected, the hold recall alarm tone is not generated.
  • Page 55 Xen IPK Programming Manual Programming Procedures (Continued) Press to write the data and display the next Memory Block. Program the next Memory Block or press to go back on-line. Related Programming M.B. Number Memory Block Name 1-1-63 Hold Recall Time Selection (Exclusive)
  • Page 56: Automatic Redial Time Selection

    December 2004 NEC Business Solutions Ltd 1-1-04 Automatic Redial Time System Mode Selection Submode General Description Data No. If a called party is busy, the station user dials an Access Code and restores the handset. Use this Memory Block to define the redial timing parameters when automatic redial is set to a busy CO/ PC Programming PBX number.
  • Page 57: Start Timer Selection

    Xen IPK Programming Manual 1-1-05 Start Timer Selection System Mode General Description Submode Use this Memory Block to specify the time needed after dialling before the system starts the Elapsed Call Timer, SMDR Start Timer, and Talk Start Timer. Data No.
  • Page 58 December 2004 NEC Business Solutions Ltd Programming Procedures (Continued) Press to write the data and display the next Memory Block. Program the next Memory Block or press to go back on-line. Related Programming M.B. Number Memory Block Name 1-5-25 SMDR Valid Call Timer Assignment...
  • Page 59: Co/Pbx Incoming Ringing Alarm Time Selection

    Xen IPK Programming Manual 1-1-06 CO/PBX Incoming Ringing System Mode Alarm Time Selection Submode General Description Data No. Use this Memory Block to specify the time interval between the time a CO/PBX call is detected and the time the ringing tone changes to a higher pitch when the call is not answered. If No Limit PC Programming is selected, the ringing tone does not change.
  • Page 60 December 2004 NEC Business Solutions Ltd Related Programming M.B. Number Memory Block Name 1-1-07 Tie Line Delay Ringing Timer Selection 3-07 CO/PBX Ringing Variation Selection 4-01 CO/PBX Ring Assignment (Day Mode) 4-02 CO/PBX Ring Assignment (Night Mode) 4-68 Telephone Ringing Variation Selection...
  • Page 61: Tie Line Delay Ringing Timer Selection

    Xen IPK Programming Manual 1-1-07 Tie Line Delay Ringing System Mode Timer Selection Submode General Description Data No. A Tie line call ringing at a station can begin ringing at other preassigned stations if it is not answered in a predetermined time. This Memory Block defines the time, and CO/PBX Ringing PC Programming Assignment defines the preassigned station.
  • Page 62 December 2004 NEC Business Solutions Ltd Related Programming M.B. Number Memory Block Name 1-1-34 Tie Line First Ring Pattern Selection 4-01 CO/PBX Ring Assignment (Day Mode) 4-02 CO/PBX Ring Assignment (Night Mode) 4-12 Line Key Selection for Telephone Mode 4-71...
  • Page 63: Manual Pause Selection

    Xen IPK Programming Manual 1-1-09 Manual Pause Selection System Mode General Description Submode Use this Memory Block to specify either Pause Insertion or Last Number Dialled/Speed Dial to be executed using the Redial key if it is pressed after one or more digits of a dialled number Data No.
  • Page 64: System Transfer/Camp-On Selection

    December 2004 NEC Business Solutions Ltd 1-1-11 System Transfer/Camp-On System Mode Selection Submode General Description Data No. Use this Memory Block to allow or deny (system-wide) station users the ability to perform a Ring Transfer or Station Camp-On. If allowed, Multiline Terminal users can perform a Ring Transfer by pressing the Transfer key.
  • Page 65: Station Transfer/Camp-On Recall Timer Selection

    Xen IPK Programming Manual 1-1-12 Station Transfer/Camp-On System Mode Recall Timer Selection Submode General Description Data No. Use this Memory Block to specify the time interval before a Ring Transfer or Station Camp-On from a station (without an Attendant Add-On Console) recalls back to the originating station when the call is not answered.
  • Page 66 December 2004 NEC Business Solutions Ltd Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Note: to move cursor left. Class 1 to Class 4 = 060 secs to move cursor right. Setting Data (Allow): Class 1 to Class 4: 000 to 999...
  • Page 67: Co Transfer Ring Pattern Selection

    Xen IPK Programming Manual 1-1-13 CO Transfer Ring Pattern System Mode Selection Submode General Description Data No. Use this Memory Block to select a Ring Pattern when CO transfers are made. PC Programming Display Data Setting Page + BCS Title...
  • Page 68 December 2004 NEC Business Solutions Ltd The Ring Patterns are shown in the table below: s= seconds Line Pattern Tone LK 1 Tone LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 LK 1 (Pg. 2) LK 2 (Pg.
  • Page 69: Co Transfer Ring Tone Selection

    Xen IPK Programming Manual 1-1-14 CO Transfer Ring Tone System Mode Selection Submode General Description Data No. Use this Memory Block to select a ring tone for CO transfers. PC Programming Display Data Setting + BCS Title Data 1 4 : C O T R F...
  • Page 70: System Speed Dial Restriction By Tenant

    December 2004 NEC Business Solutions Ltd 1-1-18 System Speed Dial Restriction System Mode by Tenant Submode General Description Data No. Use this Memory Block to specify whether or not System Speed Dial is restricted for each tenant. PC Programming Display...
  • Page 71 Xen IPK Programming Manual Programming Procedures Go off-line. Press LK1 + LK1 + to access the Memory Block. Press the corresponding CO/PBX line key to change the tenant number. Default Values All System Speed Dial buffers can Speed Dial buffers have nine groups. These groups are listed in the table be dialled from any tenant.
  • Page 72 December 2004 NEC Business Solutions Ltd 1. One or more tenants can be enabled to use each group. 2. Use this Memory Block to assign which tenants use each group. 3. When speed dial is set to 1000, 900~999 cannot be restricted.
  • Page 73: Line Selection For Automatic Outgoing Calls

    Xen IPK Programming Manual 1-1-19 Line Selection for Automatic System Mode Outgoing Calls Submode General Description Data No. Use this Memory Block to specify which trunks will be used when a call is made using the Code Restriction Password Override Feature.
  • Page 74: Did Digit Length Selection

    December 2004 NEC Business Solutions Ltd 1-1-20 DID Digit Length Selection System Mode General Description Submode This Memory Block defines the Direct Inward Dialling (DID) digit length in Memory Block 1-1-22. Data No. Display PC Programming Data Setting Title Data...
  • Page 75: Did Digit Conversion Assignment

    Xen IPK Programming Manual 1-1-21 DID Digit Conversion System Mode Assignment Submode General Description Data No. Use this Memory Block to enable the DID Digit Conversion Table & DNIS Assignment, Memory Block 1-1-22, for each number. If No is assigned here, only Memory Block 5-00 has an impact on incoming DID numbers.
  • Page 76: Did Digit Conversion Table & Dnis Assignment

    December 2004 NEC Business Solutions Ltd 1-1-22 DID Digit Conversion Table System Mode & DNIS Assignment Submode General Description Data No. Up to 200 incoming DID numbers can be assigned individually to ring at preassigned extension numbers on a day mode and night mode basis. This Memory Block applies to the DID number after it is modified by Memory Block 5-00.
  • Page 77 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name 4-02 CO/PBX Ring Assignment (Night Mode) 4-09 Telephone to Tenant Assignment 5-00 Digit Add/Del for Tie Line Networking 1. LK1 - Call come in as direct indial. 2. LK2 - Calls will ring as a normal CO Ring and following Ring Assignment Day/Night.
  • Page 78: Did Forward Station Number For Busy Station Or Undefined Digit

    December 2004 NEC Business Solutions Ltd 1-1-23 DID Forward Station System Mode Number for Busy Station or Submode Undefined Digit Data No. General Description PC Programming This Memory Block is used when Memory Block 1-1-21 DID Digit Conversion Assignment is enabled.
  • Page 79 Xen IPK Programming Manual 1. MB 1-1-23 DID Forward Station Number for Busy Station or Undefined Digit is only used when MB 1-1-21 DID Digit Conversion Assignment is enabled (e.g. set to ‘Y’). 2. Call Forward Busy, Station Hunting or Call Alert Notification should be used to accommodate direct indial calls to busy stations.
  • Page 80: Pbx/Ctx Access Code Assignment I

    December 2004 NEC Business Solutions Ltd 1-1-24 PBX/CTX Access Code System Mode Assignment I Submode General Description Data No. Use this Memory Block to specify a PBX line PBX/CTX Access Code together with pauses for outgoing calls. PC Programming Display...
  • Page 81: Pbx/Ctx Access Code Assignment Ii

    Memory Block Name 3-92 Trunk Type Selection Example: Xen IPK Xen IPK System Intercom Line PBX Line Tie Line 1. Features such as Code Restriction do not operate properly unless a PBX/CTX Access Code is specified. This limitation only applies to PBX lines assigned in Memory Block 3-92 Trunk Type Selection.
  • Page 82: Automatic Day/Night Mode Switching Time Assignment

    December 2004 NEC Business Solutions Ltd 1-1-27 Automatic Day/Night Mode System Mode Switching Time Assignment Submode General Description Data No. Use this Memory Block to assign Pattern 1 and Pattern 2 start times for automatically switching between Day Mode and Night Mode.
  • Page 83 Xen IPK Programming Manual 1. The start times for Day Mode or Night Mode can be specified in System Programming to automatically switch modes at the specified times. 2. A start time for Day Mode only or Night Mode only cannot be programmed.
  • Page 84: Distinctive Ringing By Telephone Or Co Selection

    December 2004 NEC Business Solutions Ltd 1-1-28 Distinctive Ringing by System Mode Telephone or CO Selection Submode General Description Data No. Use this Memory Block to assign distinctive ringing tone for each telephone or each CO/PBX line. PC Programming Display...
  • Page 85: Private Line Assignment

    Xen IPK Programming Manual 1-1-29 Private Line Assignment System Mode General Description Submode Use this Memory Block to assign an outside line for use as a private line. The private line cannot be seized by any other telephone, and no LED indication is provided to other terminals.
  • Page 86: Route Advance Block Assignment

    December 2004 NEC Business Solutions Ltd 1-1-30 Route Advance Block System Mode Assignment Submode General Description Data No. Use this Memory Block to assign priority levels (1~4) to each Trunk Group assigned in a Route Advance Block. The system has 32 blocks that can be specified.
  • Page 87 Xen IPK Programming Manual 1. If 00 (Not Set) is programmed, no trunks are accessed for this priority setting. 2. If Route Advance Block Numbers are assigned and a line key is pressed or an Access Code is dialled, the system starts searching for an idle line in a specified group (beginning with the Trunk Group assigned priority 1).
  • Page 88: Automatic Day/Night Mode By Day Of Week Selection

    December 2004 NEC Business Solutions Ltd 1-1-32 Automatic Day/Night Mode by System Mode Day of Week Selection Submode General Description Data No. Use this Memory Block to select either Pattern 1 or Pattern 2 Day/Night Mode start times for each day of the week. Memory Block 1-1-27 Automatic Day/Night Mode Switching Time...
  • Page 89 Xen IPK Programming Manual By designating two time settings in Memory Block 1-1-27 Automatic Day/Night Mode Switching Time Assignment, one of the two settings can be assigned to each day of the week. For Example: To specify Day/Night Mode automatic switching time for Monday ~ Friday, and Day/Night Mode automatic switching time for Saturday and Sunday, press CO/PBX line keys 1 and 7.
  • Page 90: Speed Dial Number/Name Display Selection

    December 2004 NEC Business Solutions Ltd 1-1-33 Speed Dial Number/Name System Mode Display Selection Submode General Description Data No. Use this Memory Block to specify whether the dialled number or name is displayed first on the LCD of the originating station when an outgoing call is made using Speed Dial.
  • Page 91: Tie Line First Ring Pattern Selection

    Xen IPK Programming Manual 1-1-34 Tie Line First Ring Pattern System Mode Selection Submode General Description Data No. Use this Memory Block to set specific ringing tones for incoming calls on Tie lines. After a delay interval specified in Memory Block 1-1-07...
  • Page 92 December 2004 NEC Business Solutions Ltd Ringing Pattern Selection s= seconds Pattern Same as Internal Ring Voice Announce DRAFT 3 72 – Chapter 1 Tie Line First Ring Pattern Selection, 1-1-34...
  • Page 93: Speed Dial Buffer Allocation

    Xen IPK Programming Manual 1-1-35 Speed Dial Buffer Allocation System Mode General Description Submode Use this Memory Block to specify either 100-memory or 1000-memory allocation. Data No. Display Data Setting Title Data PC Programming 3 5 : S P D...
  • Page 94: Trunk Queuing Timeout Selection

    December 2004 NEC Business Solutions Ltd 1-1-37 Trunk Queuing Timeout System Mode Selection Submode General Description Data No. Use this Memory Block to specify the time that a station with Trunk Queue set rings, before the queue is automatically cancelled.
  • Page 95 Xen IPK Programming Manual Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Note: to move cursor left. Class 1 to Class 4 = 10 secs to move cursor right. Setting Data (Allow): Class 1 to Class 4: 000 to 999...
  • Page 96: Access Code (1-Digit) Assignment

    December 2004 NEC Business Solutions Ltd 1-1-46 Access Code (1-Digit) System Mode Assignment Submode General Description Data No. Use this Memory Block to assign a 1-digit number as an Access Code or station number. PC Programming Display Data Dial No. 0~9...
  • Page 97 Xen IPK Programming Manual 1. Select options from the list of function numbers in Memory Block 1-1-46 Access Code (1-Digit) Assignment, and assign a number (from 0~9), , or # to each selected function. • When a function is assigned a 1-digit Access Code, 2-digit Access Codes with the same first digit become invalid (i.e., if a function is assigned to Access Code 5, Access Codes 50~59, 5 , and 5# cannot be used.)
  • Page 98 December 2004 NEC Business Solutions Ltd This table applies to Data Numbers 46, 47, and 48. Default Dial Numbers and Function Numbers Default Dial Numbers and Function Numbers Default Function Default Function Function Name Function Name Dial No. Dial No.
  • Page 99 Xen IPK Programming Manual Default Dial Numbers and Function Numbers Default Dial Numbers and Function Numbers Default Function Default Function Function Name Function Name Dial No. Dial No. Internal/External Meet-Me Trunk Group 06 All External Zone Paging External Zone A Paging...
  • Page 100 December 2004 NEC Business Solutions Ltd Default Dial Numbers and Function Numbers Default Dial Numbers and Function Numbers Default Function Default Function Function Name Function Name Dial No. Dial No. Specified Station Access Code Specified Station Access Code Route Advance Block 32...
  • Page 101: Access Code (2-Digit) Assignment

    Xen IPK Programming Manual 1-1-47 Access Code (2-Digit) System Mode Assignment Submode General Description Data No. Use this Memory Block to assign a 2-digit number as an Access Code. PC Programming Display Data Dial No. 0~9 Function + BA Title...
  • Page 102: Access Code (3-Digit) Assignment

    December 2004 NEC Business Solutions Ltd 1-1-48 Access Code (3-Digit) System Mode Assignment Submode General Description Data No. Use this Memory Block to assign a 3-digit number as an Access Code. PC Programming Display Dial No. Third Digit Data Table No.
  • Page 103 Xen IPK Programming Manual 1. Select options from the list of function numbers in Memory Block 1-1-46 Access Code (1-Digit) Assignment, and assign a 3-digit Access Code. • When a function is assigned a 1-digit Access Code or 2-digit Access Code, 3-digit Access Codes (with the same first digit) become invalid (i.e., if a function is assigned to Access Code 5, Access Codes 50~59, 5 , and 5#...
  • Page 104: Networking Trunk Group/Route Advance Assignment

    December 2004 NEC Business Solutions Ltd 1-1-49 Networking Trunk Group/ System Mode Route Advance Assignment Submode General Description Data No. Use this Memory Block to assign the function number of the Trunk Group to be used to network an Xen system to another system by Tie lines or CO/PBX/CTX lines.
  • Page 105: Co/Pbx Outgoing Digit Add Assignment

    Xen IPK Programming Manual 1-1-50 CO/PBX Outgoing Digit Add System Mode Assignment Submode General Description Data No. Use this Memory Block to specify up to 10 additional digits when a trunk in the Trunk Group or Route Advance block assigned in Memory Block 1-1-49 Networking Trunk Group/Route Advance Assignment is seized, and a number is dialled.
  • Page 106 December 2004 NEC Business Solutions Ltd Station 100 Example: Dials 200 Xen IPK Xen IPK System System Trunk Group 02 Station 200 Rings To assign System 1 in System Programming: → 1. Memory Block 1-1-46 Access Code (1-Digit) Assignment. Assignment 2 401 (Closed Number Block 01).
  • Page 107: Co Line Ringing Pattern Selection

    Xen IPK Programming Manual 1-1-51 CO Line Ringing Pattern System Mode Selection Submode General Description Data No. Use this Memory Block to assign the initial ringing pattern for incoming calls on a CO line. PC Programming Display Data Setting Page...
  • Page 108 December 2004 NEC Business Solutions Ltd The Ring Patterns are shown in the table below: s= seconds Pattern No Ring DRAFT 3 88 – Chapter 1 CO Line Ringing Pattern Selection, 1-1-51...
  • Page 109: Pbx Line Ringing Pattern Selection

    Xen IPK Programming Manual 1-1-52 PBX Line Ringing Pattern System Mode Selection Submode General Description Data No. Use this Memory Block to assign the initial ringing pattern for incoming calls on a PBX line. PC Programming Display Data Setting Page...
  • Page 110 December 2004 NEC Business Solutions Ltd The Ring Patterns are listed in the table below: s= seconds Pattern No Ring DRAFT 3 90 – Chapter 1 PBX Line Ringing Pattern Selection, 1-1-52...
  • Page 111: Tie Line Delay Ring Pattern Selection

    Xen IPK Programming Manual 1-1-53 Tie Line Delay Ring Pattern System Mode Selection Submode General Description Data No. Use this Memory Block to select a ringing pattern for incoming calls on a Tie line after the timeout set in Memory Block 1-1-07.
  • Page 112 December 2004 NEC Business Solutions Ltd The Ring Patterns are shown in the table below: s= seconds Pattern No Ring DRAFT 3 92 – Chapter 1 Tie Line Delay Ring Pattern Selection, 1-1-53...
  • Page 113: Automated Attendant Transfer Ring Pattern

    Xen IPK Programming Manual 1-1-54 Automated Attendant Transfer System Mode Ring Pattern Submode General Description Data No. Use this Memory Block to specify the ringing pattern sent to the Multiline Terminal when an incoming call is received at the Automated Attendant and transferred.
  • Page 114 December 2004 NEC Business Solutions Ltd The Ring Patterns are shown in the table below: s= seconds Pattern No Ring DRAFT 3 94 – Chapter 1 Automated Attendant Transfer Ring Pattern, 1-1-54...
  • Page 115: Did Line Ringing Pattern Selection

    Xen IPK Programming Manual 1-1-55 DID Line Ringing Pattern System Mode Selection Submode General Description Data No. This Memory Block assigns the ringing pattern to be used for DID calls. PC Programming Display Data Setting Page + ALN Title Data...
  • Page 116: Co/Pbx Prepause Timer Selection

    December 2004 NEC Business Solutions Ltd 1-1-57 CO/PBX Prepause Timer System Mode Selection Submode General Description Data No. Use this Memory Block to assign a pause time before dialled digits can be sent over a CO/PBX line after the trunk is seized by a system user.
  • Page 117: Synchronous Ringing Selection

    Xen IPK Programming Manual 1-1-59 Synchronous Ringing System Mode Selection Submode General Description Data No. Use this Memory Block to specify whether or not CO/PBX calls follow Synchronous Ringing. PC Programming Display Data Function + BCS Title 5 9 : S Y N C H R O N U S...
  • Page 118: Digit Matching Table Assignment

    December 2004 NEC Business Solutions Ltd 1-1-60 8-Digit Matching Table System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the outgoing dial digit for Code Restriction (except OCC Dial Digit - Normal Dial). Program this assignment in one of two ways:...
  • Page 119 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name Refer to Section 6 Code Restriction in this chapter. There are sixteen 8-Digit Matching Tables. Each 8-digit table contains 16 Dial Codes. Each dial code can have eight characters including digits and/or , #, X, P, or N characters.
  • Page 120: Digit Matching Table To Class Assignment

    December 2004 NEC Business Solutions Ltd 1-1-61 8-Digit Matching Table to System Mode Class Assignment Submode General Description Data No. Use this Memory Block to program, per Class, each 8-digit Matching Table to allow or deny. Classes 00 and 15 are fixed. Only classes 01 14 can be programmed.
  • Page 121 Xen IPK Programming Manual Table Class A = Allow D = Deny DRAFT 3 1-1-61, 8-Digit Matching Table to Class Assignment Chapter 1 – 101...
  • Page 122: System Speed Dial Override By Class Selection

    December 2004 NEC Business Solutions Ltd 1-1-62 System Speed Dial Override System Mode by Class Selection Submode General Description Data No. Use this Memory Block to specify, per Class, whether or not a user can override System Speed Dial. PC Programming...
  • Page 123: Hold Recall Time Selection (Exclusive)

    Xen IPK Programming Manual 1-1-63 Hold Recall Time Selection System Mode (Exclusive) Submode General Description Data No. Use this Memory Block to specify the time for Exclusive Hold Recall. If No Limit is selected, Exclusive Hold Recall is not provided.
  • Page 124 December 2004 NEC Business Solutions Ltd Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Note: to move cursor left. Class 1 to Class 4 = 60 secs to move cursor right. Setting Data (Allow): Class 1 to Class 4: 000 to 999...
  • Page 125: Attendant Add-On Console Transfer/Camp-On Recall Timer Selection

    Xen IPK Programming Manual 1-1-64 Attendant Add-On Console System Mode Transfer/Camp-On Recall Submode Timer Selection Data No. General Description PC Programming Use this Memory Block to specify the time interval before a Ring Transfer or Station Camp-On from a station with an Attendant Add-On Console recalls back to the originating station if the call + BM is not answered.
  • Page 126: Code Restriction Class Allow/Deny Selection

    December 2004 NEC Business Solutions Ltd 1-1-65 Code Restriction Class Allow/ System Mode Deny Selection Submode General Description Data No. Use this Memory Block to assign Code Restriction Classes 01~14 as Allow or Deny. This assignment is used when there is no match or there is an overlap (duplicate numbers in tables with opposite assignments) of numbers in the 8-Digit Matching Tables.
  • Page 127: Digit Matching Table To Normal Dial Assignment

    Xen IPK Programming Manual 1-1-66 8-Digit Matching Table to System Mode Normal Dial Assignment Submode General Description Data No. Use this Memory Block to assign the 8-Digit Matching Table by class for normal dialling as used or unused. If unused is assigned, the system does not check during normal dialling even if Memory Block 1-1-61 8-Digit Matching Table to Class Assignment is programmed.
  • Page 128: Occ Table Assignment

    December 2004 NEC Business Solutions Ltd 1-1-67 OCC Table Assignment System Mode General Description Submode Use this Memory Block to assign an Other Common Carrier (OCC) code (8-digit maximum) in a table. A maximum of 16 codes can be assigned.
  • Page 129: Digit Matching Table To Occ Table Assignment

    Xen IPK Programming Manual 1-1-68 8-Digit Matching Table to System Mode OCC Table Assignment Submode General Description Data No. Use this Memory Block to assign each 8-Digit Matching Table to each Other Common Carrier (OCC) Code Table. PC Programming Display...
  • Page 130: Tie Line Code Restriction Assignment

    December 2004 NEC Business Solutions Ltd 1-1-69 Tie Line Code Restriction System Mode Assignment Submode General Description Data No. Use this Memory Block to assign Restriction/No Restriction to outgoing Tie line dialled digits. PC Programming Display Data Title Setting + AC...
  • Page 131: Code Restriction Class Assignment When Lockout Is Set

    Xen IPK Programming Manual 1-1-70 Code Restriction Class System Mode Assignment when Lockout Submode is Set Data No. General Description PC Programming Use this Memory Block to assign the Code Restriction Class when a station user sets the Station Lockout or when the Attendant sets Attendant Station Lockout.
  • Page 132: First Delay Announcement Start Time Selection

    December 2004 NEC Business Solutions Ltd 1-1-71 First Delay Announcement System Mode Start Time Selection Submode General Description Data No. Use this Memory Block to specify the delay between receiving a CO call and sending a First Delay Announcement to the calling party.
  • Page 133: First Delay Announcement Repeat Selection

    Xen IPK Programming Manual 1-1-72 First Delay Announcement System Mode Repeat Selection Submode General Description Data No. Use this Memory Block to specify the number of times a First Delay Announcement is repeated. PC Programming Display Data Setting + AR...
  • Page 134: First To Second Delay Announcement Interval Time Selection

    December 2004 NEC Business Solutions Ltd 1-1-73 First to Second Delay System Mode Announcement Interval Submode Time Selection Data No. General Description PC Programming Use this Memory Block to specify the interval time between the end of the First Delay Announcement sending time and the start time of the Second Delay Announcement.
  • Page 135: Second Delay Announcement Repeat Selection

    Xen IPK Programming Manual 1-1-74 Second Delay Announcement System Mode Repeat Selection Submode General Description Data No. Use this Memory Block to specify the number of times a Second Delay Announcement is repeated. PC Programming Display + AR Data Setting...
  • Page 136: Second Delay Announcement Repeat Interval Time Selection

    December 2004 NEC Business Solutions Ltd 1-1-75 Second Delay Announcement System Mode Repeat Interval Time Selection Submode General Description Data No. Use this Memory Block to specify the interval time to repeat Second Delay Announcement to the calling party. PC Programming...
  • Page 137: Barge-In Alert Tone Assignment

    Xen IPK Programming Manual 1-1-76 Barge-In Alert Tone System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the delayed ringing timer for incoming outside line calls. Applicable to IPK R2000 and above. PC Programming + BTS...
  • Page 138: Delayed Ringing Timer Assignment (Co)

    December 2004 NEC Business Solutions Ltd 1-1-77 Delayed Ringing Timer System Mode Assignment (CO) Submode General Description Data No. Use this Memory Block to assign the delayed ringing timer for incoming outside line calls. PC Programming Display Data Setting + BCM...
  • Page 139: Caller Id Display Assignment For System Mode

    Xen IPK Programming Manual 1-1-78 Caller ID Display Assignment System Mode for System Mode Submode General Description Data No. Use this Memory Block to assign up to 15 Multiline Terminals to display Caller ID Indication for normal incoming CO/PBX calls or CO/PBX calls ringing a Call Arrival (CAR) key.
  • Page 140: Bgm Port Assignment

    December 2004 NEC Business Solutions Ltd 1-1-79 BGM Port Assignment System Mode General Description Submode Use this Memory Block to assign the CO/PBX port to use as a Background Music port. Data No. Display Data Title CO No. (01~64) PC Programming...
  • Page 141: Isdn Dtmf Duration/Interdigit Time Selection

    Xen IPK Programming Manual 1-1-80 ISDN DTMF Duration/ System Mode Interdigit Time Selection Submode General Description Data No. Use this Memory Block to specify tone duration and interdigit time of Dual-Tone Multifrequency (DTMF) signals for the ISDN trunk. PC Programming...
  • Page 142: Isdn Dial Interval Timer

    December 2004 NEC Business Solutions Ltd 1-1-81 ISDN Dial Interval Timer Submode General Description Submode Use this Memory Block to specify the Dial Interval Timer for ISDN lines. Data No. With IPK R2000 and above, this memory block allows flexible entries and has four classes.
  • Page 143 Xen IPK Programming Manual Programming Procedures (Continued) Press to write the data. Press to go back on-line. Related Programming M.B. Number Memory Block Name 3-92 Trunk (Installed, DP/DTMF) Selection 4-71 Time Class Assignment for Telephone Mode (R2000 and above) DRAFT 3 1-1-81, ISDN Dial Interval Timer Chapter 1 –...
  • Page 144: Code Restriction Bypass Table

    Submode This Memory Block assigns a set of feature codes per system. A Station user can dial these codes as the leading digits of a telephone number. The Xen IPK system ignores these digits and Data No. applies code restriction to the remaining digits. The codes are sent to the CO as the leading digits on permitted code restriction calls.
  • Page 145: Isdn Stimulus Method Selection

    Xen IPK Programming Manual 1-1-85 ISDN Stimulus Method System Mode Selection Submode General Description Data No. Use this Memory Block to specify the country in which the system is being used. This determines the method to be used when activating ISDN supplementary services (stimulus mode).
  • Page 146: Call Monitoring Alert Assignment

    December 2004 NEC Business Solutions Ltd 1-1-86 Call Monitoring Alert System Mode Assignment Submode General Description Data No. Use this Memory Block to specify whether or not Call Monitoring Alert Tone is allowed. When allowed, the Conference LED indicates Call Monitoring. When denied, the Conference LED does not indicate Call Monitoring.
  • Page 147: Internal Paging Timeout Selection

    Xen IPK Programming Manual 1-2-00 Internal Paging Timeout System Mode Selection Submode General Description Data No. Use this Memory Block to program the time allowed for paging. With IPK R2000 and above, this memory block allows flexible entry and four Classes.
  • Page 148 December 2004 NEC Business Solutions Ltd Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Note: to move cursor left. Class 1 to Class 4 = 10 secs to move cursor right. Setting Data (Allow): Class 1 to Class 4: 000 to 255 sec 000 = No Limit NOTE: CCIS Network Class 1 is used.
  • Page 149: Intercom Call Voice/Tone Signal Selection

    Xen IPK Programming Manual 1-2-01 Intercom Call Voice/Tone System Mode Signal Selection Submode General Description Data No. Use this Memory Block to determine whether signal tone or voice is used first for an intercom call. PC Programming Display Data Setting...
  • Page 150: Automatic Callback Release Timer Selection

    December 2004 NEC Business Solutions Ltd 1-2-02 Automatic Callback Release System Mode Timer Selection Submode General Description Data No. Use this Memory Block to determine the time allowed for an automatic callback before the request is automatically cancelled. PC Programming With IPK R2000 and above, this memory block allows flexible entry and four Classes.
  • Page 151 Xen IPK Programming Manual Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Note: to move cursor left. Class 1 to Class 4 = 30 secs to move cursor right. Setting Data (Allow): Class 1 to Class 4: 00 to 99 sec...
  • Page 152: Or 4-Digit Station Number Selection

    December 2004 NEC Business Solutions Ltd 1-2-03 2-, 3-, or 4-Digit Station System Mode Number Selection Submode General Description Data No. Use this Memory Block to determine the number of digits for station numbers. Either 2-digit (00~99), 3-digit (000~999), or 4-digit (0000~9999) assignment is available.
  • Page 153: Call Arrival Key Block Assignment

    Xen IPK Programming Manual 1-2-04 Call Arrival Key Block System Mode Assignment Submode General Description Data No. Use this Memory Block to specify the number of Call Arrival keys that can be used in the system. PC Programming Display Data...
  • Page 154 Refer to Chapter 2 Guide to Feature Programming. 1. The Xen IPK system allows a maximum of 120 ports to be shared by station ports (ESI, SLI, VMS) and Call Arrival Keys. If 32 station ports are being used, 88 remain for use as Call Arrival Keys.
  • Page 155: Specified Station Access Code Assignment

    1-4-15 Automated Attendant Message Access Code (2-Digit) Assignment 1. Specified stations can be accessed from intercom (ICM) dial tone or as an outside caller calling into the Xen IPK system via Auto Attendant. 2. The Specified Access Code is assigned in Memory Blocks 1-1-46 , Access Code (1-Digit) Assignment or 1-1-47, Access Code (2-Digit) Assignment.
  • Page 156: Customised Message 1~10 Assignment

    December 2004 NEC Business Solutions Ltd 1-2-09~18 Customised Message 1~10 System Mode Assignment Submode General Description Data No. Use this Memory Block to program various messages for display at a station LCD. When a user 09~18 places an intercom (ICM) call from a station equipped with an LCD display to a station in DND mode, the appropriate programmed message displays at the calling station.
  • Page 157: Intercom Ring Pattern Selection

    Xen IPK Programming Manual 1-2-19 Intercom Ring Pattern System Mode Selection Submode General Description Data No. Use this Memory Block to select a ring pattern when intercom calls are made. PC Programming Display Data Setting Page Title Data 1 9 :...
  • Page 158 December 2004 NEC Business Solutions Ltd The Ring Patterns are listed in the table below: s= seconds Line Pattern Tone LK 1 Tone LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 LK 1 (Pg. 2) LK 2 (Pg.
  • Page 159: Intercom Ring Tone Selection

    Xen IPK Programming Manual 1-2-20 Intercom Ring Tone Selection System Mode General Description Submode Use this Memory Block to select a ring tone for intercom calls. Data No. Display Data Setting Title Data PC Programming 2 0 : I C M...
  • Page 160: Phs Telephone Assignment

    December 2004 NEC Business Solutions Ltd 1-2-21 PHS Telephone Assignment System Mode General Description Submode Use this Memory Block to specify the number of PHS Telephones that can be used in the system. Data No. Display Data Setting Title Data...
  • Page 161 2. The Xen IPK expanded system can support a maximum of 40 PS II stations. 3. The Xen IPK basic system can have 32 ports to be shared by station ports (ESI, SLI, FMS/VMS, CTI, CNF, and OPX), Call Arrival Keys, and PS stations. If 24 station ports are being used, eight remain for use as PS stations.
  • Page 162: Call Forward No Answer Timer Selection

    December 2004 NEC Business Solutions Ltd 1-2-22 Call Forward No Answer System Mode Timer Selection Submode General Description Data No. Use this Memory Block to specify the time before incoming intercom calls or incoming CO/PBX lines are forwarded to another station number if the called party does not answer.
  • Page 163 Xen IPK Programming Manual Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Note: to move cursor left. Class 1 to Class 4 = 12 secs to move cursor right. Setting Data (Allow): Class 1 to Class 4: 01 to 99 sec Press to write the data.
  • Page 164: System Call Park Recall Time Selection

    December 2004 NEC Business Solutions Ltd 1-2-23 System Call Park Recall System Mode Time Selection Submode General Description Data No. Use this Memory Block to specify the time before a CO/PBX call recalls back to a station from Call Park.
  • Page 165 Xen IPK Programming Manual Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Note: to move cursor left. Class 1 to Class 4 = 60 secs to move cursor right. Setting Data (Allow): Class 1 to Class 4: 001 to9 99 sec Press to write the data.
  • Page 166: Intercom Feature Access Code Assignment

    December 2004 NEC Business Solutions Ltd 1-2-24 Intercom Feature Access System Mode Code Assignment Submode General Description Data No. Use this Memory Block to assign the Access Code for Voice/Tone change or Step Call. PC Programming Display Data Setting Title...
  • Page 167 Xen IPK Programming Manual 1. Features can be assigned to more than one dial number. 2. To enter or # under Dial Numbers Selection, press or #. DRAFT 3 1-2-24, Intercom Feature Access Code Assignment Chapter 1 – 147...
  • Page 168: Internal Paging Alert Tone Selection

    December 2004 NEC Business Solutions Ltd 1-2-25 Internal Paging Alert Tone System Mode Selection Submode General Description Data No. Use this Memory Block to determine whether or not a call alert tone is provided when Internal Paging is used. PC Programming...
  • Page 169: Delayed Ringing Timer Assignment (Icm)

    Xen IPK Programming Manual 1-2-26 Delayed Ringing Timer System Mode Assignment (ICM) Submode General Description Data No. Use this Memory Block to assign the delayed ringing timer for incoming internal calls. PC Programming Display Data Setting + BI Title Data...
  • Page 170: Ps Out Of Area Tone Selection

    December 2004 NEC Business Solutions Ltd 1-2-28 PS Out of Area Tone Selection System Mode General Description Submode Use this Memory Block to specify whether a call to a PS Handset which is currently out of coverage area will receive Busy Tone (BT) or Ring Back Tone (RBT).
  • Page 171: Ps Out Of Area Timer Selection (Bsu Only)

    Xen IPK Programming Manual 1-2-30 PS Out of Area Timer System Mode Selection (BSU only) Submode General Description Data No. Use this Memory Block to specify the retry time when a Dterm PS is Out of Area. PC Programming Display...
  • Page 172: Call Pickup Group - Direct

    December 2004 NEC Business Solutions Ltd 1-2-31 Call Pickup Group - Direct System Mode General Description Submode Text to be inserted Data No. Display Data 0~30 Setting Title Group Entry Data PC Programming 3 1 : P I C K O / 0 1...
  • Page 173: Bounce Protect Time Selection

    Xen IPK Programming Manual 1-3-01 Bounce Protect Time Selection System Mode General Description Submode Use this Memory Block to specify the time before a valid hookflash is detected from a Single Line Telephone or Voice Mail system. Data No. Display...
  • Page 174: Slt Hookflash Signal Selection

    December 2004 NEC Business Solutions Ltd 1-3-02 SLT Hookflash Signal System Mode Selection Submode General Description Data No. Use this Memory Block to specify whether a line is held internally, or if behind a PBX, a hookflash (HF) signal is sent to the line when a Single Line Telephone user performs a hookflash.
  • Page 175: First Digit Pbr Release Timer Selection

    Xen IPK Programming Manual 1-3-03 First Digit PBR Release Timer System Mode Selection Submode General Description Data No. Use this Memory Block to specify how long a Push Button Receiver (PBR) receiver circuit is connected when a dual-tone multifrequency (DTMF) Single Line Telephone user goes off-hook.
  • Page 176 December 2004 NEC Business Solutions Ltd Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: 10 secs Note: to move cursor left. to move cursor right. Setting Data (Allow): Class 1 to Class 4: 01 to 99 sec Press to write the data.
  • Page 177: Dial 1 (Dp) Hookflash Selection

    Xen IPK Programming Manual 1-3-04 Dial 1 (DP) Hookflash System Mode Selection Submode General Description Data No. Use this Memory Block to specify whether or not pressing 1 during an intercom call or a CO/PBX call on a dial pulse (DP) Single Line Telephone provides a hookflash signal.
  • Page 178: Hookflash Start Time Selection

    December 2004 NEC Business Solutions Ltd 1-3-05 Hookflash Start Time System Mode Selection Submode General Description Data No. Use this Memory Block to specify the minimum hookflash duration from Single Line Telephone. PC Programming Display Data Setting Page + BTI...
  • Page 179: Hookflash End Time Selection

    Xen IPK Programming Manual 1-3-06 Hookflash End Time Selection System Mode General Description Submode Use this Memory Block to specify the maximum hookflash duration from a Single Line Telephone to receive a second dial tone. Data No. Display Data Setting...
  • Page 180: Voice Mail Digit Add Assignment

    December 2004 NEC Business Solutions Ltd 1-3-07 Voice Mail Digit Add System Mode Assignment Submode General Description Data No. Use this Memory Block to assign up to four digits in front of the station number sent to the voice mail when a call is forwarded.
  • Page 181: Voice Mail Dtmf Delay Timer Selection

    Xen IPK Programming Manual 1-3-08 Voice Mail DTMF Delay System Mode Timer Selection Submode General Description Data No. Use this Memory Block to specify the delay time before dual-tone multifrequency (DTMF) tones are sent from Voice Mail Interface (VMI) ports.
  • Page 182: Voice Mail Disconnect Time Selection

    December 2004 NEC Business Solutions Ltd 1-3-09 Voice Mail Disconnect Time System Mode Selection Submode General Description Data No. Use this Memory Block to specify the length of a disconnect signal sent to the voice mail equipment. PC Programming Display...
  • Page 183: Voice Mail Dtmf Duration/Interdigit Time Selection

    Xen IPK Programming Manual 1-3-10 Voice Mail DTMF Duration/ System Mode Interdigit Time Selection Submode General Description Data No. Use this Memory Block to specify dual-tone multifrequency (DTMF) duration and interdigit time for Voice Mail. PC Programming Display + AV...
  • Page 184: Slt/Phs Talk Start Timer

    December 2004 NEC Business Solutions Ltd 1-3-11 SLT/PHS Talk Start Timer System Mode General Description Submode Use this Memory Block to assign the time needed after a hookflash and dialling before three- party (two Cos and one SLT) line conference is allowed from a Single Line Telephone or Data No.
  • Page 185: Tandem Transfer Automatic Disconnect Timer Selection

    Xen IPK Programming Manual 1-4-00 Tandem Transfer Automatic System Mode Disconnect Timer Selection Submode General Description Use this Memory Block to specify maximum time before the system automatically disconnects a Data No. Trunk-to-Trunk connection. PC Programming With IPK R2000 and above, this memory block allows flexible entry.
  • Page 186: Automated Attendant First Digit Pbr Release Timer Selection

    December 2004 NEC Business Solutions Ltd 1-4-01 Automated Attendant First System Mode Digit PBR Release Timer Selection Submode Data No. General Description Use this Memory Block to specify the time a Push Button Receiver (PBR) circuit remains PC Programming connected after the Automated Attendant message is played when a calling party calls in through + AU an Automated Attendant trunk.
  • Page 187 Xen IPK Programming Manual Programming Procedures Use the dial pad to enter the time required. Default values: 20 secs Note: to move cursor left. to move cursor right. Setting Data (Allow): 01 to 99 sec Press to write the data.
  • Page 188: Automated Attendant Transfer Delayed Ringing Time Selection

    December 2004 NEC Business Solutions Ltd 1-4-02 Automated Attendant System Mode Transfer Delayed Ringing Time Selection Submode Data No. General Description Use this Memory Block to specify the time that a call rings at the destination station before the PC Programming automated attendant rings a programmed station.
  • Page 189 Xen IPK Programming Manual Programming Procedures Use the dial pad to enter the time required. Default values: Class 1 to Class 4 = 00 secs Note: to move cursor left. (00 = No Limit) to move cursor right. Setting Data (Allow): Class 1 to Class 4: 01 to 99 sec...
  • Page 190: Automated Attendant No Answer Disconnect Time Selection

    December 2004 NEC Business Solutions Ltd 1-4-03 Automated Attendant No System Mode Answer Disconnect Time Selection Submode Data No. General Description Use this Memory Block to establish how long the Automated Attendant rings a station before PC Programming automatically disconnecting the caller.
  • Page 191 Xen IPK Programming Manual Programming Procedures Use the dial pad to enter the time required. Default value: 120 sec Note: to move cursor left. to move cursor right. Setting Data (Allow): 001 to 255 sec Press to write the data.
  • Page 192: Tandem Transfer Smdr Print Extension Assignment

    December 2004 NEC Business Solutions Ltd 1-4-04 Tandem Transfer SMDR Print System Mode Extension Assignment Submode General Description Use this Memory Block to specify a special number to be output from Station Message Detail Data No. Recording (SMDR) to indicate an automatic Trunk-to-Trunk transfer.
  • Page 193: Automatic Tandem Trunk By Night Mode Selection

    Xen IPK Programming Manual 1-4-05 Automatic Tandem Trunk by System Mode Night Mode Selection Submode General Description This Memory Block is used to establish whether or not the Automatic Trunk-to-Trunk Transfer Data No. feature follows the Night Mode assignment. PC Programming...
  • Page 194: Automated Attendant Pbr Timeout Response Selection

    December 2004 NEC Business Solutions Ltd 1-4-08 Automated Attendant PBR System Mode Timeout Response Selection Submode General Description Use this Memory Block to specify how a call answered by the Automated Attendant should be Data No. processed if a dual-tone multifrequency (DTMF) tone is not received.
  • Page 195: Automated Attendant Pbr Start Time Selection

    Xen IPK Programming Manual 1-4-09 Automated Attendant PBR System Mode Start Time Selection Submode General Description This Memory Block is used to specify whether the Push Button Receiver (PBR) can receive dual- Data No. tone multi frequency (DTMF) signalling while the Automated Attendant is sending the message or after the message is complete.
  • Page 196: Automated Attendant Message Day Night Mode Selection

    December 2004 NEC Business Solutions Ltd 1-4-11 Automated Attendant Message System Mode Day Night Mode Selection Submode General Description Use this Memory Block to specify Automated Attendant messages that are available for use in a Data No. Day/Night Mode setting.
  • Page 197: Automated Attendant Message To Tenant Assignment

    Xen IPK Programming Manual 1-4-12 Automated Attendant Message System Mode to Tenant Assignment Submode General Description Use this Memory Block to assign Automated Attendant Messages to Tenant. Data No. Display PC Programming A.A. Data Setting + AU Data Title 1 2 : A A...
  • Page 198: Automated Attendant Answer Delay Time Assignment

    December 2004 NEC Business Solutions Ltd 1-4-13 Automated Attendant Answer System Mode Delay Time Assignment Submode General Description Use this Memory Block is assign the number of seconds before the Automated Attendant Data No. answers an incoming CO/PBX call. PC Programming Display A.A.
  • Page 199: Automated Attendant Message Access Code (1-Digit Assignment

    Xen IPK Programming Manual 1-4-14 Automated Attendant Message System Mode Access Code (1-Digit) Assignment Submode Data No. General Description Use this Memory Block to enter a 1-digit code to route an incoming call from the Automated PC Programming Attendant. + AU Display A.A.
  • Page 200 December 2004 NEC Business Solutions Ltd 1. Function 011 (Bypass Automated Attendant) uses Memory Blocks , 4-01 , CO/PBX Ring Assignment (Day Mode) and , 4-02 , CO/PBX Ring Assignment (Night Mode) to ring according to those assignments. 2. Functions 015~016 (Ring Internal Paging Zone A/B/C) require assigning the following to ring the desired station:...
  • Page 201 Xen IPK Programming Manual 1-Digit Access Codes (Continued) Function Function Contents Contents Code Code DSS 1 Call Specified Station Call (17) DSS 2 Call Specified Station Call (18) DISA Access Code Specified Station Call (19) Specified Station Call (20) Specified Station Call (21)
  • Page 202: Automated Attendant Message Access Code (2-Digit Assignment

    December 2004 NEC Business Solutions Ltd 1-4-15 Automated Attendant Message System Mode Access Code (2-Digit) Assignment Submode Data No. General Description Use this Memory Block to enter a 2-digit code to route an incoming call from the Automated PC Programming Attendant.
  • Page 203: Automated Attendant Message Repeat Selection

    Xen IPK Programming Manual 1-4-16 Automated Attendant Message System Mode Repeat Selection Submode General Description Use this Memory Block to specify the number of times a message from the Automated Attendant Data No. Is repeated to the calling party. PC Programming Display A.A.
  • Page 204: Automated Attendant Delay Announcement Hold Tone Selection

    December 2004 NEC Business Solutions Ltd 1-4-17 Automated Attendant Delay System Mode Announcement Hold Tone Selection Submode Data No. General Description Use this Memory Block to specify the tone that is sent to the outside party after the Automated PC Programming Attendant Delay Announcements are played.
  • Page 205: Automated Attendant Delay Announcement Assignment

    Xen IPK Programming Manual 1-4-18 Automated Attendant Delay System Mode Announcement Assignment Submode General Description Use this Memory Block to specify the order for the Automated Attendant messages that are Data No. played when in the Delayed Announcement Mode. PC Programming...
  • Page 206: Automated Attendant 1 St To 2 Nd Delay Announcement Interval Time Selection

    December 2004 NEC Business Solutions Ltd 1-4-19 Automated Attendant 1 to 2 System Mode Delay Announcement Interval Time Selection Submode Data No. General Description Use this Memory Block to specify the interval time between the Automated Attendant Delay PC Programming Announcement messages.
  • Page 207: Automated Attendant Delay Announcement Disconnect Time Selection

    Xen IPK Programming Manual 1-4-20 Automated Attendant Delay System Mode Announcement Disconnect Time Selection Submode Data No. General Description Use this Memory Block to establish how long the Automated Attendant rings the stations before PC Programming disconnecting the caller. This Memory Block only applies when the Automated Attendant is set to the Delay Announcement Mode.
  • Page 208: Automated Attendant Extension Number Assignment

    December 2004 NEC Business Solutions Ltd 1-4-21 Automated Attendant System Mode Extension Number Assignment Submode Data No. General Description Use this Memory Block to assign the extension number of each AA message. PC Programming Display + AU A.A. Msg. Data...
  • Page 209: Programming Procedures

    Xen IPK Programming Manual 1-4-22 Automated Attendant Direct System Mode Extension Ring or Ring Assignment Submode Data No. General Description Use this Memory Block to ring at an extension or normal ringing after the AA PBR timer expires PC Programming...
  • Page 210 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 190 – Chapter 1 Automated Attendant Direct Extension Ring or Ring Assignment, 1-4-22...
  • Page 211: Press The Corresponding Co/Pbx Line Key To Change The Data Option

    Xen IPK Programming Manual 1-5-02 SMDR Print Format System Mode General Description Submode Use this Memory Block to specify whether or not ALL digits are to be printed. If All is specified, all digits are printed. If MASK is specified, the last four digits are masked and XXXX is printed.
  • Page 212: Printer Connected Selection

    December 2004 NEC Business Solutions Ltd 1-5-13 Printer Connected Selection System Mode General Description Submode Use this Memory Block to program when a printer or PC is connected for SMDR use. If the printer is disconnected from the system, an alarm sounds at stations connected to Ports 01 and 02.
  • Page 213: Printer Line Feed Control Selection

    Xen IPK Programming Manual 1-5-14 Printer Line Feed Control System Mode Selection Submode General Description This Memory Block specifies the format of the data sent to the Station Message Detail Recording Data No. (SMDR) printer. If YES is set, a carriage return is provided with the call record.
  • Page 214: Outgoing Mode Selection

    December 2004 NEC Business Solutions Ltd 1-5-23 Outgoing Mode Selection System Mode General Description Submode Use this Memory Block to specify whether a station’s Extension Number or ID Number is to be printed in SMDR call records. Also, setting this to “ID” allows use of the Code Restriction Password Override facility, in preference to the Forced Account Code facility.
  • Page 215: Default Values

    Xen IPK Programming Manual 1-5-25 SMDR Valid Call Timer System Mode Assignment Submode General Description Use this Memory Block to assign the minimum length of a call before the Station Message Detail Data No. Recording (SMDR) outputs a record of the outgoing CO/PBX call.
  • Page 216: Smdr Incoming/Outgoing Print Selection

    December 2004 NEC Business Solutions Ltd 1-5-26 SMDR Incoming/Outgoing System Mode Print Selection Submode General Description Use this Memory Block to specify the type of call records to be output from the Station Message Data No. Detail Recording (SMDR): OUT = print outgoing call records only, INC = print incoming call records only, ALL = print incoming and outgoing call records.
  • Page 217: Attendant Add-On Console To Telephone Port Assignment

    Xen IPK Programming Manual 1-6-00 Attendant Add-On Console to System Mode Telephone Port Assignment Submode General Description Data No. Use this Memory Block to assign an Attendant Add-On Console to a telephone port number. PC Programming Display Data DSS No.
  • Page 218: Dss Call Voice/Tone Signal Selection

    December 2004 NEC Business Solutions Ltd 1-6-03 DSS Call Voice/Tone Signal System Mode Selection Submode General Description Data No. Use this Memory Block to specify which is to be used first, Voice or Tone signalling, when calling an extension from an Attendant Add-On Console.
  • Page 219: Attendant Add-On Console Key Selection

    Xen IPK Programming Manual 1-6-05 Attendant Add-On Console System Mode Key Selection Submode General Description Data No. Use this Memory Block to assign functions to the Attendant Add-On Console keys. PC Programming Display Data DSS No. Button No. Setting Page...
  • Page 220 December 2004 NEC Business Solutions Ltd Programming Procedures Press the corresponding CO/PBX line key and dial pad keys to change the data Default Values option: Key No. Data Setting Functions can be assigned to keys 01~60 on Attendant Add-On Consoles 1~4.
  • Page 221 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name 1-6-00 Attendant Add-On Console to Telephone Port Assignment Telephone Type Assignment 1. When TEL is assigned to a line key, the red LED is used to indicate Station Status.
  • Page 222: Attendant Transfer Selection During Live Record

    December 2004 NEC Business Solutions Ltd 1-6-08 Attendant Transfer Selection System Mode During Live Record Submode General Description Data No. This Memory Block controls the behavior of the Attendant DSS/BLF transfer while the Attendant is engaged in a live recording operation. The call is either transferred to the DSS/BLF extension or the voice mail box of the DSS/BLF extension.
  • Page 223: Doorphone Assignment

    Xen IPK Programming Manual 1-7-00 Doorphone Assignment System Mode General Description Submode Use this Memory Block to enable the doorphones in System Programming. Display Data No. Data Title PC Programming 0 0 : D P H A S S I G N...
  • Page 224: Doorphone Display Time Selection

    December 2004 NEC Business Solutions Ltd 1-7-01 Doorphone Display Time System Mode Selection Submode General Description Use this Memory Block to define how long a doorphone call signals a station before it times out. Data No. With IPK R2000 and above, this memory block allows flexible entry.
  • Page 225 Xen IPK Programming Manual Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: 10 secs Note: to move cursor left. to move cursor right. Setting Data (Allow): 01 to 99 sec Press to write the data.
  • Page 226: External Speaker Connection Selection

    December 2004 NEC Business Solutions Ltd 1-7-02 External Speaker Connection System Mode Selection Submode General Description Use this Memory Block to specify whether or not external speakers are connected to the system. Data No. Display PC Programming Data Title + BP...
  • Page 227: External Paging Alert Tone Selection

    Xen IPK Programming Manual 1-7-03 External Paging Alert Tone System Mode Selection Submode General Description Use this Memory Block to specify whether or not a paging alert tone is sent on External Zone Data No. Paging (all speakers/individual speaker). PC Programming...
  • Page 228: Doorphone Ringing Pattern Selection

    December 2004 NEC Business Solutions Ltd 1-7-04 Doorphone Ringing Pattern System Mode Selection Submode General Description Use this Memory Block to define the doorphone ringing cycle. Each doorphone can be Data No. individually assigned. PC Programming Display + BTP Setting...
  • Page 229: Doorphone Ringing Frequency Selection

    Xen IPK Programming Manual 1-7-05 Doorphone Ringing System Mode Frequency Selection Submode General Description Use this Memory Block to define the doorphone ringing frequency. Each doorphone can be Data No. individually assigned. PC Programming Display + BTP Setting Data Data...
  • Page 230: 2.0 Min

    December 2004 NEC Business Solutions Ltd 1-7-06 External Paging Timeout System Mode Selection Submode General Description Use this Memory Block to specify the time allowed for External Paging before timeout and Data No. release of the paging circuit. PC Programming With IPK R2000 and above, this memory block allows flexible entry and four Classes.
  • Page 231: Related Programming

    Xen IPK Programming Manual Programming Procedures (Continued) Use the dial pad to enter the time required. Default values: Class 1 to Class 4 = 300 secs Note: to move cursor left. to move cursor right. Setting Data (Allow): Class 1 to Class 4: 000 to 999 sec NOTE: CCIS Network use Class 1 only.
  • Page 232: External Ring Relay Cycle Selection

    December 2004 NEC Business Solutions Ltd 1-7-07 External Ring Relay Cycle System Mode Selection Submode General Description Use this Memory Block to assign one of six distinctive ringing controls/intervals to relay circuits. Data No. Display PC Programming Ext Ring Relay...
  • Page 233 Xen IPK Programming Manual An External Tone relay or the Night Chime relay must be assigned in Memory Block 2-08 ECR Relay to Tenant Assignment before the tone is generated from JK1. s= seconds Cycle Continuous DRAFT 3 1-7-07, External Ring Relay Cycle Selection...
  • Page 234: External Speaker Chime Selection

    December 2004 NEC Business Solutions Ltd 1-7-08 External Speaker Chime System Mode Selection Submode General Description Use this Memory Block to determine whether paging alert tone (4 tones) or alert chime sounds Data No. before the speech path is established, or after, or before and after.
  • Page 235: External Speaker Chime Start Time Selection

    Xen IPK Programming Manual 1-7-09 External Speaker Chime Start System Mode Time Selection Submode General Description This Memory Block is used only when paging alert tone (4-tones) is assigned in Memory Block 1- Data No. 7-08 (External Speaker Chime Selection). This Memory Block assigns the delay after an external paging code is dialled and before the paging alert tone is provided.
  • Page 236 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 216 – Chapter 1 External Speaker Chime Start Time Selection, 1-7-09...
  • Page 237: Slt Or Automated Attendant/Disa To Pbr Selection

    Xen IPK Programming Manual 1-8-01 SLT or Automated Attendant/ System Mode DISA to PBR Selection Submode General Description Data No. Use this Memory Block to specify whether the four Push Button Receiver (PBR) circuits in the CPUI( )-U( ) ETU Unit are used for Single Line Telephones or the Automated Attendant/Direct Inward System Access (DISA).
  • Page 238: Pbr Receive Level Assignment For Automated Attendant Disa

    December 2004 NEC Business Solutions Ltd 1-8-02 PBR Receive Level System Mode Assignment for Automated Submode Attendant/DISA Data No. General Description PC Programming Use this Memory Block to specify the receiving level of the Push Button Receiver (PBR) at the Automated Attendant/Direct Inward System Access (DISA).
  • Page 239: Time Display (12H/24H) Selection

    Xen IPK Programming Manual 1-8-04 Time Display (12h/24h) System Mode Selection Submode General Description Data No. Use this Memory Block to specify either a 12-hour (12:00 a.m. to 11:59 p.m.) or 24-hour (00:00 to 23:59) time display. PC Programming Display...
  • Page 240: Class Of Service (Attendant) Feature Selection 1

    December 2004 NEC Business Solutions Ltd 1-8-07 Class of Service (Attendant) System Mode Feature Selection 1 Submode General Description Data No. Use this Memory Block to allow or deny specific attendant features for each Class Of Service. When individual stations are assigned, the station user can access only the features designated allow.
  • Page 241 Xen IPK Programming Manual Programming Procedures (Continued) Press the corresponding CO/PBX line key to enter data. The LED indication changes to indicate the data each time a CO/PBX line key is pressed. CO/PBX Refer to Table on following Line Key LED page for default settings.
  • Page 242 December 2004 NEC Business Solutions Ltd Classes 00 15 are programmed in this Memory Block as feature restriction classes. In Memory Block 4-17 Station to Class of Service Feature Assignment specify any class of service for each telephone to assign the features the user can/ cannot activate.
  • Page 243: Class Of Service (Station) Feature Selection 2

    Xen IPK Programming Manual 1-8-08 Class of Service (Station) System Mode Feature Selection 2 Submode General Description Data No. Use this Memory Block to allow or deny specific station features for each Class of Service. When individual stations are assigned, the station user can access only the features designated allow.
  • Page 244 December 2004 NEC Business Solutions Ltd Programming Procedures Go off-line.9 Press LK1 + LK8 + to access the Memory Block. Press the corresponding CO/PBX line key to change the data option. The LED indication changes to indicate data each time CO/PBX line key is pressed.
  • Page 245 Xen IPK Programming Manual Corresponding Default Default Function Name CO/PBX Line Key Class 00 Class 01 General Purpose Relay Allow Deny Voice Override/Tone Override Originate Allow Deny Page 02 Absence Message Allow Deny Callback Request Originate Allow Deny Station Outgoing Lockout (Set/Cancel)
  • Page 246 December 2004 NEC Business Solutions Ltd Corresponding Default Default Function Name CO/PBX Line Key Class 00 Class 01 Page 04 LCR Recall Allow Deny DSS Key Transfer Operation Operation applies to Feature Access/One-Touch Deny Deny keys and Attendant Add-On console keys programmed for DSS.
  • Page 247 Xen IPK Programming Manual Corresponding Default Default Function Name CO/PBX Line Key Class 00 Class 01 Page 06 ACR Normal Originate Deny Deny VM MSG Key Deny Deny To turn on/off display of new message sent to a Voice Mail Box.
  • Page 248: Number Memory Block Name

    December 2004 NEC Business Solutions Ltd 1-8-09 Music on Hold Pattern System Mode Selection Submode General Description Data No. Use this Memory Block to specify the Music on Hold pattern. PC Programming Display Data Setting + BCS Data Title 0 9 : M O H...
  • Page 249: Pbr Interdigit Release Timer Selection

    Xen IPK Programming Manual 1-8-10 PBR Interdigit Release Timer System Mode Selection Submode General Description Data No. Use this Memory Block to specify the interdigit release time for the Push Button Receiver (PBR). PC Programming Display Data Setting + BM...
  • Page 250 December 2004 NEC Business Solutions Ltd Off-hook Dial Tone is sent (PBR Specified Time: 10 sec. Default connected) Memory Block 1-3-03 Dial the first digit Specified Time: 7 sec. Default Memory Block 1-8-10 The second digit Specified Time: 7 sec. Default...
  • Page 251: System Refresh Timer Assignment

    Xen IPK Programming Manual 1-8-11 System Refresh Timer System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the System Refresh Time during idle periods/no change in state. PC Programming Display + BM Data Setting Title...
  • Page 252: Vrs Message Recording Time Selection

    December 2004 NEC Business Solutions Ltd 1-8-12 VRS Message Recording System Mode Time Selection Submode General Description Data No. Use this Memory Block to specify the length and number of messages for each of the eight Voice Recording Service (VRS) channels.
  • Page 253: Vrs Message Function Assignment

    Xen IPK Programming Manual 1-8-13 VRS Message Function System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the recorded voice prompt Delay Announcement/ Automated Attendant Message to the Voice Recording Service (VRS) channel. Refer to...
  • Page 254: Tone Assignment

    December 2004 NEC Business Solutions Ltd 1-8-15 Tone Assignment System Mode General Description Submode Use this Memory Block to assign each system tone to the flexible tables. Data No. Display Item Data Setting Page PC Programming (00~12) Tone Data + BI...
  • Page 255 Xen IPK Programming Manual Default Table Table Number Tone Default ICM Dial Tone Second Dial Tone Special Dial Tone SPDT Busy Tone Reorder/Error Tone Howler Tone Service Set Tone ICM Ringback Tone RBT1 Tie/DID Ringback Tone RBT2 Call Waiting Tone...
  • Page 256 December 2004 NEC Business Solutions Ltd Tone Table Frequency Tone Intermittent Cycle (Hz) 350/440 Continuous 120 IPM 0.25 On, 0.25 Off 0.25 On, 1.25 Off 240 IPM 0.125 On, 0.125 Off 80 IPM 0.375 On, 0.375 Off 2.5 On, 0.5 Off...
  • Page 257: Voice Prompt To Tone Assignment

    Xen IPK Programming Manual 1-8-16 Voice Prompt to Tone System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the voice prompt to each tone. Voice prompt is provided only during the Internal Dial tone or Call Waiting tone.
  • Page 258: Pc Programming Password Assignment

    December 2004 NEC Business Solutions Ltd 1-8-17 PC Programming Password System Mode Assignment Submode General Description Data No. Use this Memory Block to assign system passwords that must be entered when connecting to the system using MAT PC Programming. PC Programming...
  • Page 259: Site Name Assignment

    Xen IPK Programming Manual 1-8-18 Site Name Assignment System Mode General Description Submode Use this Memory Block to indicate a system name for PC Programming software to use to program the system. Data No. Display Class Data Setting PC Programming No.
  • Page 260: Acd/Ucd Group Agent Assignment

    December 2004 NEC Business Solutions Ltd 1-8-25 ACD/UCD Group Agent System Mode Assignment Submode General Description Data No. Use this Memory Block to specify the Agent Extension Number and the Automatic Call Distribution/Uniform Call Distribution (ACD/UCD) Group Numbers where each agent is assigned.
  • Page 261: Voice Mail Quick Transfer Master Hunt Number

    Xen IPK Programming Manual 1-8-26 Voice Mail Quick Transfer System Mode Master Hunt Number Submode General Description Data No. Use this Memory Block to specify a Voice Mail Master Hunt Number to operate Quick Transfer to Voice Mail. This Memory Block also enables the voice mail display in the LCD of a Multiline Terminal when a voice mail machine sets a message.
  • Page 262: Forced Account Code Length Assignment

    December 2004 NEC Business Solutions Ltd 1-8-27 Forced Account Code Length System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the digit length of the Forced Account Codes. PC Programming Display Data Setting + BF...
  • Page 263: Scd (Simplified Call Distribution) Pilot Number Assignment

    Xen IPK Programming Manual 1-8-29 SCD (Simplified Call System Mode Distribution) Pilot Number Submode Assignment Data No. General Description PC Programming Use this Memory Block to define the SCD Pilot number for each of the four groups. It can be any valid unused station number.
  • Page 264: Scd Group Agent Assignment

    December 2004 NEC Business Solutions Ltd 1-8-30 SCD Group Agent Assignment System Mode General Description Submode Use this Memory Block to assign stations to one of four simplified call distribution groups. A total of 32 stations can be assigned. Data No.
  • Page 265: Hold Tone Source Selection

    Xen IPK Programming Manual 1-8-31 Hold Tone Source Selection System Mode General Description Submode Use this Memory Block to assign an internal or external Music on Hold source. Data No. Display Data Setting Title Data PC Programming 2 7 : H L D T...
  • Page 266: Hold Internal Tone Volume Selection

    December 2004 NEC Business Solutions Ltd 1-8-32 Hold Internal Tone Volume System Mode Selection Submode General Description Data No. When the internal Music On Hold source is used, this Memory Block is used to pad the music by -6 dB.
  • Page 267: Master Clock Selection

    Xen IPK Programming Manual 1-8-33 Master Clock Selection System Mode General Description Submode When either a PRT(1)-U( ) or BRT(4)-U( ) ETU is installed, clocking must be synchronised. This Memory Block assigns the source to be synchronised with. Enter the cabinet/slot number of Data No.
  • Page 268: Com Port Baud Rate Setting Assignment

    December 2004 NEC Business Solutions Ltd 1-8-35 COM Port Baud System Mode Rate Setting Assignment Submode General Description Data No. Use this Memory Block to define the baud rates for all three COM ports individually. PC Programming Display Data Setting...
  • Page 269: Com Port Parity/Stop Bit Setting Assignment

    Xen IPK Programming Manual 1-8-36 COM Port Parity/Stop Bit System Mode Setting Assignment Submode General Description Data No. Use this Memory Block to define the Parity and Stop bit for the individual COM ports. PC Programming Display Data Setting + CSS...
  • Page 270: General Purpose Relay Assignment

    December 2004 NEC Business Solutions Ltd 1-8-37 General Purpose Relay System Mode Assignment Submode General Description Data No. Use this Memory Block to specify whether or not the General Purpose Relays on the ECR-U13 ETU are used. PC Programming Display...
  • Page 271: Modem Port For Remote Programming Assignment

    Xen IPK Programming Manual 1-8-38 Modem Port for Remote System Mode Programming Assignment Submode General Description Data No. A socket modem can be installed on the MIFM-U( ) ETU when it is installed in S1 or S2 of the B64-U23 KSU. Use this Memory Block to assign the extension number for the socket modem.
  • Page 272: Acd Hunt Timer

    December 2004 NEC Business Solutions Ltd 1-8-40 ACD Hunt Timer System Mode General Description Submode Use this Memory Block to assign the time value for hunting among the Automatic Call Distribution/Uniform Call Distribution (ACD/UCD) agents that do not answer an ACD/UCD call.
  • Page 273: Car For Voice Mail Message Notice Assignment

    Xen IPK Programming Manual 1-8-47 CAR for Voice Mail Message System Mode Notice Assignment Submode General Description Data No. Use this Memory Block to assign the Call Arrival Key that is used to send Voice Mail message notification to other systems.
  • Page 274: New Aa-Info Yes/No Selection

    December 2004 NEC Business Solutions Ltd 1-8-49 New AA-Info Yes/No Selection System Mode General Description Submode Use this Memory Block to specify whether or not New AA-Info is allowed. New Application-to- Application (AA) Info is used with internal Voice Mail Systems (i.e., FMS( )-U( ) or VMS( )-U( ) Data No.
  • Page 275: Disa/Id Code Assignment

    Xen IPK Programming Manual 1-9-00 DISA/ID Code Assignment System Mode General Description Submode This Memory Block specifies the Direct Inward System Access (DISA) ID Code numbers. Data No. Display ID Buffer No. Data Setting (01~C0) Title Data PC Programming 0 1 / 0 0 : C O D E...
  • Page 276: Disa/Id Password Effect/Invalid Selection

    December 2004 NEC Business Solutions Ltd 1-9-02 DISA/ID Password Effect/ System Mode Invalid Selection Submode General Description Data No. Use this Memory Block to assign a Direct Inward System Access (DISA) Password as Invalid (LK1) or Effective (LD2). If invalid is assigned, the calling party can use the DISA feature without a DISA Password.
  • Page 277: Id Restriction Class Assignment (Day Mode)

    Xen IPK Programming Manual 1-9-03 ID Restriction Class System Mode Assignment (Day Mode) Submode General Description Data No. Use this Memory Block to specify the DAY mode code restriction classes for each ID number. PC Programming Display ID Buffer No.
  • Page 278 December 2004 NEC Business Solutions Ltd Related Programming (Continued) M.B. Number Memory Block Name 4-26 DISA/ID Number Station Assignment 4-27 ID Outgoing Restriction Selection DRAFT 3 258 – Chapter 1 ID Restriction Class Assignment (Day Mode), 1-9-03...
  • Page 279: Id Restriction Class Assignment (Night Mode)

    Xen IPK Programming Manual 1-9-04 ID Restriction Class System Mode Assignment (Night Mode) Submode General Description Data No. Use this Memory Block to specify the NIGHT mode code restriction classes for each ID number. PC Programming Display ID Buffer No.
  • Page 280 December 2004 NEC Business Solutions Ltd Related Programming (Continued) M.B. Number Memory Block Name 4-26 DISA/ID Number Station Assignment 4-27 ID Outgoing Restriction Selection DRAFT 3 260 – Chapter 1 ID Restriction Class Assignment (Night Mode), 1-9-04...
  • Page 281: T1 Signal Format Selection

    Xen IPK Programming Manual 1-11-00 T1 Signal Format Selection System Mode General Description Submode Use this Memory Block to specify the signal format of the T1 trunk connected to the system. The signal format used (12- or 24-Multiframe) depends on the channel service unit/ Data No.
  • Page 282: Clear Channel Selection

    December 2004 NEC Business Solutions Ltd 1-11-01 Clear Channel Selection System Mode General Description Submode Use this Memory Block to specify the clear channel selection. when the Zero Byte Time channel is available, the CLKG-U( ) Unit cannot extract a clock signal from the T1 Data No.
  • Page 283: Line Length Selection

    Xen IPK Programming Manual 1-11-02 Line Length Selection System Mode General Description Submode Use this Memory Block to specify the distance, in feet, between the channel service unit/ demarcation (CSU/D mark) and the DTI-U( ) ETU. This specifies the equalization values of Data No.
  • Page 284: Ip K-Ccis Selection

    December 2004 NEC Business Solutions Ltd 1-11-03 IP K-CCIS Selection System Mode General Description Submode Use this Memory Block to assign the IAD(8)-U( ) ETU used for K-CCIS over IP Data No. Applicable for R2000 and above Display PC Programming DTI No.
  • Page 285: Ti Channel Selection

    Xen IPK Programming Manual 1-11-05 TI Channel Selection System Mode General Description Submode Use this Memory Block to specify the digital trunk interface (DTI) channel numbers to be used. DTI Trunks 1 and 2 have a maximum of 24 channels, and DTI Trunk 3 has a Data No.
  • Page 286: Signalling Selection

    December 2004 NEC Business Solutions Ltd 1-11-06 Signalling Selection System Mode General Description Submode Use this Memory Block to specify Loop Start (LS) or Ground Start (GS) Trunk Signalling when using T1 Data No. Applicable for R2000 and above PC Programming...
  • Page 287: Dti Trunk Type Assignment

    Xen IPK Programming Manual 1-11-07 DTI Trunk Type Assignment System Mode General Description Submode Use this Memory Block to assign the trunk type (CO/E&M Tie line/DID/ANI) four channels at a time. Assignment to an individual channel is impossible Data No.
  • Page 288: Digits Delete For Ti Ani Assignment

    December 2004 NEC Business Solutions Ltd 1-11-08 Digits Delete for TI ANI System Mode Assignment Submode General Description Data No. Use this Memory Block to delete the Information Digits received from the Network on Feature Group D Trunks PC Programming...
  • Page 289 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name Card interface Slot Assignment 1-11-05 T1 Channel Selection 1-11-07 DTI Trunk Type Assignment Example of ANI information: KP009727517645STKP7100ST. Information digits 9727517645 ANI information 7100 DNIS Digits DRAFT 3 1-11-08, Digits Delete for TI ANI Assignment...
  • Page 290 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 270 – Chapter 1 Digits Delete for TI ANI Assignment, 1-11-08...
  • Page 291: Acd/Ucd Group Pilot Number Assignment

    Xen IPK Programming Manual 1-12-00 ACD/UCD Group Pilot System Mode Number Assignment Submode General Description Data No. Use this Memory Block to specify the Pilot Number of an Automatic Call Distribution/Uniform Call Distribution (ACD/UCD) Group where incoming calls are terminated.
  • Page 292: Acd/Ucd Group Overflow Destination Assignment

    December 2004 NEC Business Solutions Ltd 1-12-01 ACD/UCD Group Overflow System Mode Destination Assignment Submode General Description Data No. This Memory Block specifies the station or Station Hunt Group where the overflow call of each Automatic Call Distribution/Uniform Call Distribution (ACD/UCD) Group is routed when incoming calls overflow.
  • Page 293: Acd/Ucd Overflow Timer Selection

    Xen IPK Programming Manual 1-12-02 ACD/UCD Overflow Timer System Mode Selection Submode General Description Data No. This Memory Block specifies the maximum time a waiting Automatic Call Distribution/Uniform Call Distribution (ACD/UCD) call remains at an ACD/UCD Group before overflowing to a specified Station or Station Hunt Group.
  • Page 294 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 274 – Chapter 1 ACD/UCD Overflow Timer Selection, 1-12-02...
  • Page 295: Pri Channel Assignment

    Xen IPK Programming Manual 1-13-00 PRI Channel Assignment System Mode General Description Submode This Memory Block specifies the number of channels available on each PRI ISDN line connected to the system via a PRT(1)-U( ) ETU. Data No. Display Data...
  • Page 296 December 2004 NEC Business Solutions Ltd 1. PRT defaults as PRT 32. Memory Block 1-13-04 must then be programmed to show the exact number of available channel. 2. Two slots will be used for 30 B channel PRT, PRT 20, 10 take one slot.
  • Page 297: Prt B Channel Outgoing Priority Selection

    Xen IPK Programming Manual 1-13-04 PRT B Channel Outgoing System Mode Priority Selection Submode General Description Data No. Use this Memory Block to assign the Outgoing Priority for the B-channels when calls are originated on a PRT(1)-U( ) ETU. PC Programming This assignment is allowed by handset programming and SAT.
  • Page 298: Prt B Channel-To-Trunk Group Assignment

    December 2004 NEC Business Solutions Ltd 1-13-05 PRT B Channel-to-Trunk System Mode Group Assignment Submode General Description Data No. Use this Memory Block to assign a Trunk Group Number to each B channel or any Trunk Group for each B channel. Changing this assignment is not normally required and default should be set.
  • Page 299 Xen IPK Programming Manual Data assignment for above example. Memory Block Title Setting Data Slot 4: PRT/PRT (lower/upper) 7-01 Card Interface Slot Assignment Slot 5: None/None Slot 6: None/None 1-08-33 Master Clock Selection Cabinet 1, Slot 4 1-13-00 PRT Channel Assignment...
  • Page 300 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 280 – Chapter 1 PRT B Channel-to-Trunk Group Assignment, 1-13-05...
  • Page 301: Acr Feature Allow/Deny Selection

    Xen IPK Programming Manual 1-14-00 ACR Feature Allow/Deny System Mode Selection Submode General Description Data No. Use this Memory Block to specify whether or not ACR is system wide. PC Programming Display Data Setting + AO Title Data 0 0 : A C R...
  • Page 302: Acr Dialling Assignment

    December 2004 NEC Business Solutions Ltd 1-14-01 ACR Dialling Assignment System Mode General Description Submode Use this Memory Block to assign a dialling plan to one of four possible ACR Tables. Each table contains 128 maximum dialling assignments for the selected dialling plan.
  • Page 303 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name 3-03 Trunk-to-Trunk Group Assignment 4-40 LCR Class Selection 1-8-08 Class of Service (Station) Feature Selection 2 1-14-00 ACR Feature Allow/Deny Selection 1-14-01 ACR Dialled Number Dial Allow/Deny Selection 1-14-03...
  • Page 304: Acr Dialled Number Dial Allow/Deny Selection

    December 2004 NEC Business Solutions Ltd 1-14-02 ACR Dialled Number Dial System Mode Allow/Deny Selection Submode General Description Data No. Use this Memory Block to Allow or Deny digits that are entered in the ACR dialling assignment to be routed using the ACR feature.
  • Page 305 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name 3-03 Trunk-to-Trunk Group Assignment 4-40 LCR Class Selection 1-8-08 Class of Service (Station) Feature Selection 2 1-14-00 ACR Feature Allow/Deny Selection 1-14-01 ACR Dialling Assignment 1-14-03 ACR Trunk Group to Route Number Assignment...
  • Page 306: Acr Route Table Number Assignment

    December 2004 NEC Business Solutions Ltd 1-14-03 ACR Route Table Number System Mode Assignment Submode General Description Data No. Use this Memory Block to assign each ACR Dialling Assignment to an ACR Route Assignment. PC Programming Display 01~C8 + AO...
  • Page 307: Acr Trunk Group To Route Number Assignment

    Xen IPK Programming Manual 1-14-04 ACR Trunk Group to Route System Mode Number Assignment Submode General Description Data No. Use this Memory Block to specify whether a Trunk Group is used for each Route assignment. PC Programming Display Data Route...
  • Page 308: Acr Digit Delete Assignment

    December 2004 NEC Business Solutions Ltd 1-14-05 ACR Digit Delete Assignment System Mode General Description Submode Use this Memory Block to specify the number of digits to be deleted from the Route assignment. Data No. Display Data Route Setting Title...
  • Page 309: Acr Digit Add Assignment

    Xen IPK Programming Manual 1-14-06 ACR Digit Add Assignment System Mode General Description Submode Use this Memory Block to specify the number of digits to add to the Route assignment. Data No. Display Data Route Setting Data PC Programming 0 6 / 0 1 =...
  • Page 310: Acr Max Digit Assignment

    December 2004 NEC Business Solutions Ltd 1-14-07 ACR Max Digit Assignment System Mode General Description Submode Use this Memory Block to specify the number of digits to be collected by the system before the message is sent to the network Data No.
  • Page 311: K-Ccis Main/Remote Office Selection

    Xen IPK Programming Manual 1-15-00 K-CCIS Main/Remote Office System Mode Selection Submode General Description Data No. Use this Memory Block to activate CCIS by assigning a Main or Remote system Applicable for IPK R2000 and above. PC Programming + AW...
  • Page 312 4-56 SMDR Telephone Print Selection For Xen IPK to Xen IPK Network only one system can be set for Main. All other systems must be set from Remote 2. When connected to a PBX, the Xen IPK must be set for REMOTE in this Memory Block.
  • Page 313: Common Signal Channel Assignment

    Xen IPK Programming Manual 1-15-02 Common Signal Channel System Mode Assignment Submode General Description Data No. Use this Memory Block to assign a T1 Trunk to be a Common Signalling Channel Applicable for IPK R2000 and above. PC Programming + AW...
  • Page 314 December 2004 NEC Business Solutions Ltd Related Programming (Continued) M.B. Number Memory Block Name 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment...
  • Page 315: Originating Point Code Assignment

    Xen IPK Programming Manual 1-15-03 Originating Point Code System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the originating point code for each Common Signalling Channel PC Programming Applicable for IPK R2000 and above. + AW...
  • Page 316 December 2004 NEC Business Solutions Ltd Related Programming (Continued) M.B. Number Memory Block Name 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment...
  • Page 317: Destination Point Code Assignment

    Xen IPK Programming Manual 1-15-04 Destination Point Code System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the Destination Point Code for each Common Signalling Channel PC Programming Applicable for IPK R2000 and above. + AW...
  • Page 318 December 2004 NEC Business Solutions Ltd Related Programming (Continued) M.B. Number Memory Block Name 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment...
  • Page 319: Destination Point Code Transfer Assignment

    Xen IPK Programming Manual 1-15-05 Destination Point Code System Mode Transfer Assignment Submode General Description Data No. Use this Memory Block to assign the Destination Point Code to the associated Common Signalling Channel when K-CCIS commands are required to pass through a tandem system.
  • Page 320 December 2004 NEC Business Solutions Ltd Xen 100 is Master for Centralised Day/Night Mode Change (K-CCIS) Xen IPK Xen IPK Xen IPK 10 TG 10 CCIS CCIS Cabinet 1 Cabinet 1 Cabinet 1 Cabinet 1 Slot 1 Slot 1 Slot 4...
  • Page 321 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-17 Centralised BLF Send Time Assignment 1-15-18 Centralised BLF Display Extension Number Assignment 3-70 CIC Number Assignment 5-05 Common Signalling Channel Route Selection 1-1-05 Start Time Selection 1-5-02...
  • Page 322: Originating Office Code Number Assignment

    December 2004 NEC Business Solutions Ltd 1-15-06 Originating Office Code System Mode Number Assignment Submode General Description Data No. Use this Memory Block to assign the Office Code to the system when Open Numbering Plan is used PC Programming Applicable for IPK R2000 and above.
  • Page 323 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment...
  • Page 324: K-Ccis Message Response Timeout Assignment

    December 2004 NEC Business Solutions Ltd 1-15-07 K-CCIS Message Response System Mode Timeout Assignment Submode General Description Data No. Use this Memory Block to assign the time before a call or message request is cancelled when no response is received from the destination office PC Programming Applicable for IPK R2000 and above.
  • Page 325 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-10 Calling Name Display Allow/Deny Selection 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment...
  • Page 326: Link Reconnect Allow/Deny Selection

    December 2004 NEC Business Solutions Ltd 1-15-08 Link Reconnect Allow/Deny System Mode Selection Submode General Description Data No. Use this Memory Block to specify the number of digits to be collected by the system before the message is sent to the network PC Programming Applicable for IPK R2000 and above.
  • Page 327 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment...
  • Page 328: K-Ccis Maximum Call Forwarding Hop Assignment

    December 2004 NEC Business Solutions Ltd 1-15-09 K-CCIS Maximum Call System Mode Forwarding Hop Assignment Submode General Description Data No. Use this Memory Block to specify the maximum number of multiple Call Forwarding hops over the CCIS network PC Programming Applicable for IPK R2000 and above.
  • Page 329 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment 1-15-15 Centralised BLF Send Point Code Assignment...
  • Page 330: Calling Name Display Allow/Deny Selection

    December 2004 NEC Business Solutions Ltd 1-15-10 Calling Name Display Allow/ System Mode Deny Selection Submode General Description Data No. Use this Memory Block per Common Signalling Channel to allow or deny sending the station name PC Programming Applicable for IPK R2000 and above.
  • Page 331 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment 1-15-15 Centralised BLF Send Point Code Assignment...
  • Page 332: Centralised Billing Allow/Deny Selection

    Use this Memory Block to assign the to send billing to the Billing Center Electra Elite IPK Office (NEAX2000/2400) across the K-CCIS network. Xen IPK does not support receiving and managing billing information PC Programming Applicable for IPK R2000 and above.
  • Page 333 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-10 Calling Name Display Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment 1-15-14 Centralised Day/Night Switching for Main Office Assignment...
  • Page 334: Centralised Billing – Point Code Of Centre Office Assignment

    December 2004 NEC Business Solutions Ltd 1-15-12 Centralised Billing – Point System Mode Code of Centre Office Submode Assignment Data No. General Description PC Programming Use this Memory Block to assign the Common Signalling Channel number and point code of the Billing Center Office (NEAX2000/2400) + AW Applicable for IPK R2000 and above.
  • Page 335 COM Port Baud Rate Setting Assignment 4-56 SMDR Telephone Print Selection 1. The Xen IPK can be only a Remote Office for a NEAX2000/2400 Billing Center Office. When the is a tandem office and Billing Information is not required, this assignment is not Xen IPK necessary.
  • Page 336: Centralised Day/Night Switching For Remote Office Assignment

    Submode Assignment Data No. General Description PC Programming Use this Memory Block to assign the Xen IPK to switch Day/Night mode when it receives the command from a main office + AW Applicable for IPK R2000 and above. Display Data...
  • Page 337 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-09 K-CCIS Maximum Call Forwarding Hop Assignment 1-15-10 Calling Name Display Allow/Deny Selection 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment...
  • Page 338: Centralised Day/Night Switching For Main Office Assignment

    December 2004 NEC Business Solutions Ltd 1-15-14 Centralised Day/Night System Mode Switching for Main Office Submode Assignment Data No. General Description PC Programming Use this Memory Block to assign the Point Codes and the CCH Channel to control remote systems for Centralised Day/Night Switching...
  • Page 339 2. This Memory Block is used for the Main Office only. 3. Up to 16 Remote Offices can be controlled by a Main Office. 4. The Xen IPK cannot be a Main Office for a NEAX2000/2400 PBX. DRAFT 3 1-15-14, Centralised Day/Night Switching for Main Office Assignment...
  • Page 340: Centralised Blf Send Point Code Assignment

    December 2004 NEC Business Solutions Ltd 1-15-15 Centralised BLF Send Point System Mode Code Assignment Submode General Description Data No. Use this Memory Block to assign the Point Codes and the CCH Channel to control remote systems for Centralised Day/Night Switching PC Programming System Software R2000 or higher is required.
  • Page 341 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-07 K-CCIS Message Response Timeout Assignment 1-15-08 Link Reconnect Allow/Deny Selection 1-15-09 K-CCIS Maximum Call Forwarding Hop Assignment 1-15-10 Calling Name Display Allow/Deny Selection 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing –...
  • Page 342: Centralised Blf Send Extension Number Assignment

    December 2004 NEC Business Solutions Ltd 1-15-16 Centralised BLF Send System Mode Extension Number Submode Assignment Data No. General Description PC Programming Use this Memory Block to assign the Extension Numbers for sending Centralised BLF messages + AW System Software R2000 or higher is required.
  • Page 343 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name Card Interface Slot Assignment 1-8-08 Class of Service (Station) Feature Selection 2 (Page 6, LK 2) 1-15-00 K-CCIS Main/Remote Office Selection 1-15-02 Common Signal Channel Assignment 1-15-03 Originating Point Code Assignment...
  • Page 344: Centralised Blf Send Time Assignment

    December 2004 NEC Business Solutions Ltd 1-15-17 Centralised BLF Send Time System Mode Assignment Submode General Description Data No. Use this Memory Block to assign the time interval for sending BLF information across the K- CCIS Network. PC Programming System Software R2000 or higher is required.
  • Page 345 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-10 Calling Name Display Allow/Deny Selection 1-15-11 Centralised Billing Allow/Deny Selection 1-15-12 Centralised Billing – Point Code of Center Office Assignment 1-15-13 Centralised Day/Night Switching for Remote Office Assignment...
  • Page 346: Centralised Blf Receive Extension Number Assignment

    December 2004 NEC Business Solutions Ltd 1-15-18 Centralised BLF Receive System Mode Extension Number Submode Assignment Data No. General Description PC Programming Use this Memory Block to assign the Extension Numbers of remote systems to receive Centralised BLF messages. + AW System Software R2000 or higher is required.
  • Page 347 Xen IPK Programming Manual Related Programming (Continued) M.B. Number Memory Block Name 1-15-06 Originating Office Code Number Assignment 1-15-07 K-CCIS Message Response Timeout Assignment 1-15-08 Link Reconnect Allow/Deny Selection 1-15-09 K-CCIS Maximum Call Forwarding Hop Assignment 1-15-10 Calling Name Display Allow/Deny Selection...
  • Page 348 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 328 – Chapter 1 Centralised BLF Receive Extension Number Assignment, 1-15-18...
  • Page 349: Trunk To Tenant Assignment

    Xen IPK Programming Manual 2-01 Trunk to Tenant Assignment System Mode General Description Submode Use this Memory Block to assign CO/PBX lines to a tenant. — Data No. Display Tenant Data PC Programming (00~47) Trunk Title + BN 0 0 / 0 1 : T R K - T N T | 0 1...
  • Page 350 December 2004 NEC Business Solutions Ltd Programming Procedures Go off-line. Press LK2 + to access the Memory Block. Press the corresponding CO/PBX line key to change the data option. Default Values Note: Use the following to enter data: Tenant Tenant...
  • Page 351: Line Key Selection

    Xen IPK Programming Manual 2-05 Line Key Selection System Mode General Description Submode Use this Memory Block to allow the technician to specify either of two line key assignment modes — for each tenant. The choices are Tenant-Wide Mode or Telephone Mode.
  • Page 352: Line Key Selection For Tenant Mode

    December 2004 NEC Business Solutions Ltd 2-06 Line Key Selection for System Mode Tenant Mode Submode — General Description Data No. This Memory Block allows the assignment of functions to each of the CO/PBX line keys on each telephone in a tenant specified as Tenant Mode in Memory Block 2-05 Line Key Selection.
  • Page 353 Xen IPK Programming Manual Programming Procedures Press the corresponding CO/PBX line key to change the data option. Default Values The operation data includes: Line Tenant Tenant Setting Data Keys 01~47 01~08 CO/PBX lines 01~08 Not assigned Line Key Setting Data (1)
  • Page 354 December 2004 NEC Business Solutions Ltd 1. Specify Call Appearance as the call appearance number of Call Appearance Block numbers from Memory Block 4-44 Station to Call Appearance Block Assignment. 2. Use this Memory Block to assign the following functions to each of the CO/PBX line keys on each telephone in a...
  • Page 355: System Speed Dial Display Assignment

    Xen IPK Programming Manual 2-07 System Speed Dial Display System Mode Assignment Submode — General Description Data No. Use this Memory Block to specify whether or not confirmation of the Speed Dial numbers and messages stored in the system Speed Dial memory is allowed.
  • Page 356 December 2004 NEC Business Solutions Ltd Programming Procedures Go off-line. Press LK2 + to access the Memory Block. Press the CO/PBX Line key. The LED indication changes to indicate the data each Default Values time the CO/PBX line key is pressed.
  • Page 357: Ecr Relay To Tenant Assignment

    Xen IPK Programming Manual 2-08 ECR Relay to Tenant System Mode Assignment Submode — General Description Data No. Use this Memory Block to specify Tenant Assignment for External Tone Ring/Night Chime function. PC Programming Display + BN Tenant No. Data...
  • Page 358: Dial-In Tenant Incoming Limit Assignment

    December 2004 NEC Business Solutions Ltd 2-09 Dial-In Tenant Incoming System Mode Limit Assignment Submode — General Description Data No. Use this Memory Block to assign names for telephone stations. PC Programming Display Tel Port + BN Data (00~47) Title...
  • Page 359: Trunk Name/Number Assignment

    Xen IPK Programming Manual 3-00 Trunk Name/Number System Mode Assignment Submode — General Description Use this Memory Block to specify telephone name/number for the CO/PBX lines accommodated Data No. so that the information is displayed when the CO/PBX Line is seized, or during an incoming call.
  • Page 360: Trunk Status Selection

    December 2004 NEC Business Solutions Ltd 3-02 Trunk Status Selection System Mode General Description Submode Use this Memory Block to specify whether a CO/PBX line is used for call origination and termination or termination only. — Data No. Display CO/PBX...
  • Page 361: Trunk-To-Trunk Group Assignment

    Xen IPK Programming Manual 3-03 Trunk-to-Trunk Group System Mode Assignment Submode — General Description Use this Memory Block to assign a Trunk Group Number (01~32) to each CO/PBX line. Data No. Display PC Programming CO/PBX Data Trunk Group + BCT...
  • Page 362: Trunk-To-Trunk Transfer Yes/No Selection

    December 2004 NEC Business Solutions Ltd 3-04 Trunk-to-Trunk Transfer Yes/ System Mode No Selection Submode — General Description This Memory Block specifies whether or not to allow Trunk-to-Trunk Transfer. Data No. Display PC Programming CO/PBX Setting + BCT (01~64) Title...
  • Page 363: Trunk Incoming Answer Mode Selection

    Xen IPK Programming Manual 3-05 Trunk Incoming Answer System Mode Mode Selection Submode — General Description This Memory Block specifies, per outside line, the incoming answer mode (Automatic Trunk-to- Data No. Trunk Transfer, Automated Attendant, or DISA). PC Programming Display...
  • Page 364 December 2004 NEC Business Solutions Ltd 1. Only trunks assigned to TANDM TRF in this Memory Block are set or cancelled for Automatic Trunk-to-Trunk Transfer Mode when an attendant position enters 00 during the set or cancel operation. For example:...
  • Page 365: Automatic Tandem Trunk Assignment

    Xen IPK Programming Manual 3-06 Automatic Tandem Trunk System Mode Assignment Submode — General Description Use this Memory Block to specify the incoming trunk and outgoing trunk for Automatic Trunk-to- Data No. Trunk Transfer. PC Programming Display (Incoming) + AT...
  • Page 366: Co/Pbx Ringing Variation Selection

    December 2004 NEC Business Solutions Ltd 3-07 CO/PBX Ringing Variation System Mode Selection Submode — General Description Use this Memory Block to specify a ringing tone (Low, Medium, or High) for each CO/PBX line. Data No. Display PC Programming CO/PBX...
  • Page 367: Co External Source Selection

    Xen IPK Programming Manual 3-11 CO External Source Selection System Mode General Description Submode Use this Memory Block to specify which CO Trunk is to have an External Music Source — connected. A powered LIU must be used for Music Source Input. (Refer to the System Hardware Manual for details).
  • Page 368: Co Hold Melody Selection (Co)

    December 2004 NEC Business Solutions Ltd 3-12 CO Hold Melody Selection System Mode (CO) Submode — General Description Use this Memory Block assigns CO Trunks to the CO Music Source inputs set in Memory Block, Data No. 3-11. PC Programming...
  • Page 369 Xen IPK Programming Manual Example: DRAFT 3 3-12, CO Hold Melody Selection (CO) Chapter 1 – 349...
  • Page 370: Tie/Did Line Type Assignment

    December 2004 NEC Business Solutions Ltd 3-14 Tie/DID Line Type System Mode Assignment Submode — General Description Use this Memory Block to assign the method of loop supervision to be used for each Trunk Data No. associated with a Tie line.
  • Page 371: Trunk Dtmf Duration/Interdigit Selection

    Xen IPK Programming Manual 3-15 Trunk DTMF Duration/ System Mode Interdigit Selection Submode — General Description Use this Memory Block to specify the tone duration and interdigit time of dual-tone multi- Data No. frequency (DTMF) signals. PC Programming Display CO/PBX...
  • Page 372: Tie Line Prepause Time Selection

    December 2004 NEC Business Solutions Ltd 3-16 Tie Line Prepause Time System Mode Selection Submode — General Description Use this Memory Block to specify the time (prepause) when the originating side becomes able to Data No. send dial pulse or dual-tone multi-frequency (DTMF) to the distant system.
  • Page 373: Tie Line Answer Detect Time Selection

    Xen IPK Programming Manual 3-17 Tie Line Answer Detect Time System Mode Selection Submode — General Description Use this Memory Block to specify the duration between the time when the receiving Xen system Data No. answers (off-hook) and the time when it is recognised as an answer.
  • Page 374: Tie Line Release Detect Time Selection

    December 2004 NEC Business Solutions Ltd 3-18 Tie Line Release Detect Time System Mode Selection Submode — General Description Use this Memory Block to specify the duration between the time when the circuit disconnection Data No. is detected on the Tie line on the distant system side and the time when it is recognised as Tie line release.
  • Page 375 Xen IPK Programming Manual 1. Specify distinguishing circuit release from on-hook, noise, and temporary interruption. There are four probable situations for Tie line release detection: Called side hangs up first. The circuit is released 92 ms. + specified time after the other party disconnects the call.
  • Page 376: Tie Line/Co/Pbx Incoming Signal Detect Time Selection

    December 2004 NEC Business Solutions Ltd 3-19 Tie Line/CO/PBX Incoming System Mode Signal Detect Time Selection Submode — General Description Use this Memory Block to specify the duration between the time when the incoming signal from Data No. another system is detected and the time when the acknowledgment signal is sent out.
  • Page 377 Xen IPK Programming Manual Programming Procedures Go off-line. Press LK3 + to access the Memory Block. Press the corresponding CO/PBX line key to change the data option. Receiving Side Incoming Signal Detection DC Loop Supervision Time Sending Acknowledgment Signal Note:...
  • Page 378: Tie Line Loop Off-Guard Time Selection

    December 2004 NEC Business Solutions Ltd 3-20 Tie Line Loop Off-Guard Time System Mode Selection Submode — General Description Use this Memory Block to assign loop off-guard protection to prevent noise that may cause the Data No. system to be unable to answer an incoming Tie line.
  • Page 379: Tie Line Length Of Wink Signal Selection

    Xen IPK Programming Manual 3-21 Tie Line Length of Wink System Mode Signal Selection Submode — General Description Use this Memory Block to specify the duration of a wink pulse that is sent to another system. Data No. Display PC Programming...
  • Page 380 December 2004 NEC Business Solutions Ltd Related Programming No related programming is necessary for this Memory Block. Specify the Wink Start method in Memory Block , 3-24 , Tie Line Incoming Interdigit Timeout Selection. DRAFT 3 360 – Chapter 1...
  • Page 381: Tie Line Length Of Delay Signal Selection

    Xen IPK Programming Manual 3-22 Tie Line Length of Delay System Mode Signal Selection Submode — General Description Use this Memory Block to specify the time a delay pulse is sent to another system. Data No. Display PC Programming CO/PBX...
  • Page 382 December 2004 NEC Business Solutions Ltd Related Programming No related programming is necessary for this Memory Block. Specify the Delay Method in Memory Block , 3-14 , Tie/DID Line Type Assignment. DRAFT 3 362 – Chapter 1 Tie Line Length of Delay Signal Selection, 3-22...
  • Page 383: Tie Line Incoming Interdigit Timeout Selection

    Xen IPK Programming Manual 3-24 Tie Line Incoming Interdigit System Mode Timeout Selection Submode — General Description Use this Memory Block to specify a time interval during the incoming call detection process so Data No. that if an address signal is not received within a specified time, an error tone is returned to the other system.
  • Page 384 December 2004 NEC Business Solutions Ltd A timeout occurs when: A dial pulse is not received within the time specified by this Memory Block after the receiving side detects the off-hook signal. The next dial pulse is not received within the time specified by this Memory Block after the receiving side detects (receives) a dial pulse.
  • Page 385: Tie Line Wink/Delay Signal Detect Timeout Selection

    Xen IPK Programming Manual 3-25 Tie Line Wink/Delay Signal System Mode Detect Timeout Selection Submode — General Description Use this Memory Block to specify a maximum time for receiving an acknowledgment signal from Data No. a distant system before sending a busy tone.
  • Page 386 December 2004 NEC Business Solutions Ltd Related Programming No related programming is necessary for this Memory Block. If the acknowledgment signal is not received within a predetermined time after an outgoing signal is sent to the other system, a busy tone is sent to the telephone.
  • Page 387: Tie Line Dial Tone Selection

    Xen IPK Programming Manual 3-27 Tie Line Dial Tone Selection System Mode General Description Submode Use this Memory Block to specify whether or not to send a dial tone to the distant system. — Display Data No. CO/PBX Data Setting...
  • Page 388: Tie Line Reorder Tone Selection

    December 2004 NEC Business Solutions Ltd 3-28 Tie Line Reorder Tone System Mode Selection Submode — General Description Use this Memory Block to specify whether or not to send a reorder tone to the originating station Data No. when the number of a distant system is used to originate a call over a Tie line.
  • Page 389: Trunk Internal Transmit Pad Selection

    Xen IPK Programming Manual 3-29 Trunk Internal Transmit Pad System Mode Selection Submode — General Description This Memory Block specifies a volume level for calls originated from the extensions of a local Data No. system to a distant system. PC Programming...
  • Page 390 December 2004 NEC Business Solutions Ltd 1. The Xen system divides the connections into the following patterns: (Specify the sending and receiving levels of each pattern for each of the trunks.) Connections established between the intercom stations of the Pattern A (Intercom Mode) local system and trunks.
  • Page 391: Trunk Internal Receive Pad Selection

    Xen IPK Programming Manual 3-30 Trunk Internal Receive System Mode Pad Selection Submode — General Description Use this Memory Block to specify a volume level for calls coming to extensions of a local system Data No. from a distant system.
  • Page 392 December 2004 NEC Business Solutions Ltd 1. The Xen system divides the connections into the following patterns: (Specify the sending and receiving levels of each pattern for each of the trunks.) Connections established between the intercom stations of the Pattern A (Intercom Mode) local system and trunks.
  • Page 393: Trunk External Transmit Pad Selection

    Xen IPK Programming Manual 3-31 Trunk External Transmit System Mode Pad Selection Submode — General Description Use this Memory Block to specify a volume level for tandem calls through a local system to two Data No. distant systems. PC Programming...
  • Page 394 December 2004 NEC Business Solutions Ltd 1. The Xen system divides the connections into the following patterns: (Specify the sending and receiving levels of each pattern for each of the trunks.) Connections established between the intercom stations of the Pattern A (Intercom Mode) local system and trunks.
  • Page 395: Trunk External Receive Pad Selection

    Xen IPK Programming Manual 3-32 Trunk External Receive Pad System Mode Selection Submode — General Description Use this Memory Block to specify a volume level for tandem calls through a local system to two Data No. distant systems. PC Programming...
  • Page 396 December 2004 NEC Business Solutions Ltd 1. The Xen system divides the connections into the following patterns: (Specify the sending and receiving levels of each pattern for each of the trunks.) Connections established between the intercom stations of the Pattern A (Intercom Mode) local system and trunks.
  • Page 397: Disconnect Recognition Time Selection

    Xen IPK Programming Manual 3-33 Disconnect Recognition Time System Mode Selection Submode — General Description Use this Memory Block to specify the minimum time for a disconnected circuit to be Data No. accessed again. PC Programming Display CO/PBX + BCT...
  • Page 398: Automated Attendant Message To Trunk Selection

    December 2004 NEC Business Solutions Ltd 3-38 Automated Attendant Message System Mode to Trunk Selection Submode — General Description Use this Memory Block to assign the Automated Attendant Message per-CO/PBX Trunk. When Data No. the Automated Attendant Message is assigned to each CO/PBX Trunk, the system automatically answers the incoming call and sends an Automated Attendant Message to the calling party.
  • Page 399: Automatic Release Selection

    Xen IPK Programming Manual 3-39 Automatic Release Selection System Mode General Description Submode This Memory Block specifies whether or not the system is to release a trunk used to make an — outgoing call when the called party hangs. Selecting Yes will result in the system disconnecting the trunk upon the outside party hanging up.
  • Page 400: Acd/Ucd Delay Announcement Assignment

    December 2004 NEC Business Solutions Ltd 3-41 ACD/UCD Delay System Mode Announcement Assignment Submode — General Description Use this Memory Block to specify, per CO Port, whether or not ACD/UCD Delay Announcement Data No. is sent to the calling party for Day and/or Night Mode.
  • Page 401: Dit Assignment

    Xen IPK Programming Manual 3-42 DIT Assignment System Mode General Description Submode Use this Memory Block to independently assign a Day Mode direct trunk termination to a station. — Display Data No. Setting Data (Incoming) Station No. CO/PBX (2-digit: 00~99)
  • Page 402: Ana Assignment

    December 2004 NEC Business Solutions Ltd 3-43 ANA Assignment System Mode General Description Submode Use this Memory Block to assign a Night Mode Direct trunk termination to a station. — Display Data No. Setting Data Station No. (2-digit: 00~99) CO/PBX...
  • Page 403: Caller Id Display Assignment For Co/Pbx Line

    Xen IPK Programming Manual 3-44 Caller ID Display Assignment System Mode for CO/PBX Line Submode — General Description Use this Memory Block to assign one Multiline Terminal, per CO/PBX, line to display Caller ID Data No. Indication on incoming CO/PBX calls.
  • Page 404: Live Recording Trunk Selection

    December 2004 NEC Business Solutions Ltd 3-45 Live Recording Trunk System Mode Selection Submode — General Description Use this Memory Block to specify, per Trunk, Live Recording Service Mode or No Live Recording Data No. Service Mode for Digital Voice Mail.
  • Page 405: Isdn Trunk Directory Number Assignment

    Xen IPK Programming Manual 3-52 ISDN Trunk Directory System Mode Number Assignment Submode — General Description Use this Memory Block to assign the Integrated Services Digital Network (ISDN) Data No. Directory Number. PC Programming Display CO/PBX + AV Setting Data...
  • Page 406: Caller Name Indication Selection

    Program the next Memory Block or press to go back on-line, after all data is written. Related Programming M.B. Number Memory Block Name Refer to individual features in the Xen IPK Features and Specifications manual. DRAFT 3 386 – Chapter 1 Caller Name Indication Selection, 3-53...
  • Page 407 Xen IPK Programming Manual 1. LK3 is used for System Speed Dial Name Match. 2. LK3 option will check all System Speed Dial Buffer Names assigned to Speed Dial Buffer Numbers 00~79 however, if System is set to 1000 Speed Dial Mode, LK3 will only check 000~099 (the first 100 Buffer Numbers and Names) and the remainder (100~999) will not be checked.
  • Page 408: Isdn Dial-Out Sending Selection

    December 2004 NEC Business Solutions Ltd 3-57 ISDN Dial-Out Sending System Mode Selection Submode — General Description Use this Memory Block to specify whether a an ISDN call is to be sent En Block or Overlap. Data No. Applicable to IPK R2000 and above.
  • Page 409: Automated Attendant Function Selection

    Xen IPK Programming Manual 3-59 Automated Attendant System Mode Function Selection Submode — General Description Use this Memory Block to specify if the Automated Attendant is to operate in the Normal Mode, Data No. or the Automated Attendant Delay Announcement mode.
  • Page 410: Dit Delay Answer Timer Selection

    December 2004 NEC Business Solutions Ltd 3-61 DIT Delay Answer Timer System Mode Selection Submode — General Description This Memory Block is used to specify the time an incoming CO/PBX Call will ring before Data No. changing to DIT. With IPK R2000 and above, this memory block allows flexible entry.
  • Page 411 Xen IPK Programming Manual Programming Procedures Go off-line. Press LK3 + to access the Memory Block. Use the dial pad to enter the time required. Default values: Note: to move cursor left. Trunk 01~64 = 00 sec to move cursor right.
  • Page 412: Dit Tenant Assignment

    December 2004 NEC Business Solutions Ltd 3-62 DIT Tenant Assignment System Mode General Description Submode This Memory Block is used to assign a CO/PBX Line to each tenant for incoming DIT calls. — Display Data No. CO/PBX Data Tenant No.
  • Page 413 Xen IPK Programming Manual 1-Line Number to be Displayed (3-53=Name, 1-8-08 P4/LK4=OFF, 1-8-08 P5/LK7=OFF) MB , 3-70 = CO MB , 3-70 = SPD SPD Name SPD Name Name Supplied – SPD Match Clock Clock SPD Name SPD Name Name Supplied – No SPD Match...
  • Page 414: Dit Holiday Mode Enable

    December 2004 NEC Business Solutions Ltd 3-63 DIT Holiday Mode Enable System Mode General Description Submode This Memory Block is used to enable Holiday Mode checking on tenant groups for incoming — DIT calls. Data No. Display CO/PBX Data Setting...
  • Page 415: Dit Night Mode Delay Answer Enable

    Xen IPK Programming Manual 3-64 DIT Night Mode Delay System Mode Answer Enable Submode — General Description This Memory Block is used to specify whether or not the DIT Delay Answer Timer shall apply to Data No. CO/PBX calls received when the system is in Night Mode.
  • Page 416: Hold Tone Automated Attendant Selection

    December 2004 NEC Business Solutions Ltd 3-65 Hold Tone Automated System Mode Attendant Selection Submode — General Description Use this Memory Block to specify which message is to be played for a particular trunk. Data No. Display PC Programming CO/PBX...
  • Page 417: Co Line Ringing Pattern Selection For Co/Pbx Line Mode

    Xen IPK Programming Manual 3-67 CO Line Ringing Pattern Selection System Mode for CO/PBX Line Mode Submode — General Description Use this Memory Block to specify the ring pattern for incoming calls or CO lines. Data No. Display PC Programming...
  • Page 418 December 2004 NEC Business Solutions Ltd Ring Patterns are shown in the table below: s= seconds Pattern No Ring 1. This Memory Block is controlled by MB , 4-57. Calls can be CO ringing or telephone ringing. 2. This Memory Block is applicable for main software Release 4.0 and above.
  • Page 419: Cic Number Assignment

    Xen IPK Programming Manual 3-70 CIC Number Assignment System Mode General Description Submode Use this Memory Block to assign the Circuit Identification Code for each voice channel — used for K-CCIS Data No. Display CO/PBX PC Programming Data Setting (01~64)
  • Page 420: Caller Name Display Assignment

    December 2004 NEC Business Solutions Ltd 3-71 Caller Name Display Assignment System Mode General Description Submode Use this Memory Block to specify whether the network provided name or the — speed dial match name is to be displayed. Data No.
  • Page 421: Isdn Brt Connection Configuration

    Xen IPK Programming Manual 3-72 ISDN BRT Connection System Mode Configuration Submode — General Description Use this Memory Block to specify the type of Basic Rate ISDN Connection configuration Data No. required. PC Programming Display CO/PBX + AI Data Setting...
  • Page 422: Polarity Reverse Selection

    December 2004 NEC Business Solutions Ltd 3-90 Polarity Reverse Selection System Mode General Description Submode In some cases a Central Office may provide a line reversed to provide a disconnect signal. — Display Data No. CO/PBX Setting Data Data (20 digits maximum)
  • Page 423: Trunk Type Selection

    Xen IPK Programming Manual 3-91 Trunk Type Selection System Mode General Description Submode This Memory Block specifies each external line as CO line, PBX/CTX line, Tie/DID line, or CTX — Assume - 9. Data No. Display CO/PBX Data PC Programming...
  • Page 424: Trunk (Installed, Dp/Dtmf) Selection

    1. When Port 01 displays CO XX layer message, use NIL setting for unused BRI interfacing to clear display. 2. Only Tie lines and Direct Inward Dialling (DID) trunks can use dial pulse on the Xen IPK System. All other trunks must be set to multi frequency (MF).
  • Page 425: Co/Pbx Ring Assignment (Day Mode)

    Xen IPK Programming Manual 4-01 CO/PBX Ring Assignment System Mode (Day Mode) Submode — General Description Data No. Use this Memory Block to assign incoming CO/PBX calls to ring on Multiline Terminals in the Day Mode. PC Programming Display + BTT...
  • Page 426 December 2004 NEC Business Solutions Ltd Settings Page 7 (Ports 49~56) LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 Page 8 (Ports57~64) LK 1 LK 2 LK 3 LK 4 LK 5...
  • Page 427: Co/Pbx Ring Assignment (Night Mode)

    Xen IPK Programming Manual 4-02 CO/PBX Ring Assignment System Mode (Night Mode) Submode — General Description Data No. Use this Memory Block to assign incoming CO/PBX calls to ring in the Night Mode. PC Programming Display Tel Port + BTT...
  • Page 428 December 2004 NEC Business Solutions Ltd Settings Page 6 (Ports 41~48) LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 Page 7 (Ports 49~56) LK 1 LK 2 LK 3 LK 4 LK 5...
  • Page 429: Doorphone Chime Assignment (Day Mode)

    Xen IPK Programming Manual 4-03 Doorphone Chime Assignment System Mode (Day Mode) Submode — General Description Data No. Use this Memory Block to assign up to four doorphones to ring at each station in the day mode. PC Programming Display...
  • Page 430: Doorphone Chime Assignment (Night Mode)

    December 2004 NEC Business Solutions Ltd 4-04 Doorphone Chime Assignment System Mode (Night Mode) Submode — General Description Data No. Use this Memory Block to assign up to four doorphones to ring at each station in the Night Mode. PC Programming...
  • Page 431: Automatic Outgoing Co/Pbx Line Selection

    Xen IPK Programming Manual 4-05 Automatic Outgoing CO/PBX System Mode Line Selection Submode — General Description Data No. The memory block is used to determine which lines are automatically seized when an access code or Redial is pressed, and when a station goes Off-Hook (when Automatic Line Selection is set on Station).
  • Page 432 December 2004 NEC Business Solutions Ltd Settings Page 6 (Ports 41~48) LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 Page 7 (Ports 49~56) LK 1 LK 2 LK 3 LK 4 The shaded area indicates the default setting.
  • Page 433 Xen IPK Programming Manual Related Programming M.B. Number Memory Block Name 1-1-46 Access Code (1-Digit) Assignment 1-1-47 Access Code (2-Digit) Assignment 1-1-48 Access Code (3-Digit) Assignment 1. Telephone ports A0~C0 are ports 100~120. 2. Selection is made on a port by port, line by line basis.
  • Page 434: Code Restriction Class Assignment (Day Mode)

    December 2004 NEC Business Solutions Ltd 4-07 Code Restriction Class System Mode Assignment (Day Mode) Submode — General Description Data No. Use this Memory Block to specify, per station, Code Restriction Class in Day Mode. PC Programming Display Tel Port...
  • Page 435: Code Restriction Class Assignment (Night Mode)

    Xen IPK Programming Manual 4-08 Code Restriction Class System Mode Assignment (Night Mode) Submode — General Description Data No. Use this memory block to specify, per station, Code Restriction Class in Night Mode. PC Programming Display Tel Port Setting + AC...
  • Page 436: Telephone To Tenant Assignment

    December 2004 NEC Business Solutions Ltd 4-09 Telephone to Tenant System Mode Assignment Submode — General Description Data No. Use this memory block to specify, per station, Tenant Assignment. PC Programming Display Tel Port Setting + BTT Data Data (01~99)
  • Page 437: Station Number Assignment

    Xen IPK Programming Manual 4-10 Station Number Assignment System Mode General Description Submode Use this memory block to assign a station number to each telephone. — Data No. Display Tel Port Setting PC Programming Data Data (01~99) Title (00~9999) A0~C0...
  • Page 438: Ringing Line Preference Selection

    December 2004 NEC Business Solutions Ltd 4-11 Ringing Line Preference System Mode Selection Submode — General Description Data No. Use this memory block to specify whether or not each station user can answer incoming ringing CO/PBX calls by going off-hook.
  • Page 439: Line Key Selection For Telephone Mode

    Xen IPK Programming Manual 4-12 Line Key Selection for System Mode Telephone Mode Submode — General Description Data No. Use this Memory Block to assign functions to each CO/PBX line key on each telephone in a tenant specified as Telephone Mode in Memory Block , 2-05 , Line Key Selection.
  • Page 440 December 2004 NEC Business Solutions Ltd Related Programming M.B. Number Memory Block Name 2-06 Line Key Selection for Tenant Mode Function Table Functions [For each telephone in tenant specified as Setting Data 1 Line Key Setting Data 2 Telephone Mode in Memory Block 2-05...
  • Page 441: Co/Pbx Busy Forward Station Assignment

    Xen IPK Programming Manual 4-13 CO/PBX Busy Forward System Mode Station Assignment Submode — General Description Data No. Use this Memory Block to specify up to two telephones to ring when a CO/PBX call terminates at a busy station. PC Programming...
  • Page 442: Intercom Master Hunt Number Selection

    December 2004 NEC Business Solutions Ltd 4-14 Intercom Master Hunt System Mode Number Selection Submode — General Description Data No. Use this memory block to assign a master intercom number to each telephone. PC Programming Display Tel Port + BTT...
  • Page 443: Intercom Master Hunt Number Forward Assignment

    Xen IPK Programming Manual 4-15 Intercom Master Hunt System Mode Number Forward Assignment Submode — General Description Data No. Use this Memory Block to specify a telephone to ring when a Master Hunt Number specified in Memory Block , 4-14 , Intercom Master Hunt Number Selection is busy.
  • Page 444: Station To Class Of Service Feature Assignment

    December 2004 NEC Business Solutions Ltd 4-17 Station to Class of Service System Mode Feature Assignment Submode — General Description Data No. Use this Memory Block to specify, per station, a class for each Table (1 and 2) to enable/ disable features.
  • Page 445: Station Name Assignment

    Xen IPK Programming Manual 4-18 Station Name Assignment System Mode General Description Submode Use this Memory Block to assign names for telephone stations. — Data No. Display Tel Port PC Programming Data Setting (01~99) Data A0~C0 + BTT 0 1 / 1 8 : <...
  • Page 446: Trunk Outgoing Restriction

    December 2004 NEC Business Solutions Ltd 4-19 Trunk Outgoing Restriction System Mode General Description Submode Use this Memory Block to specify, per CO/PBX line, whether or not to restrict line seizure for an — outgoing call. Data No. Display Tel Port...
  • Page 447 Xen IPK Programming Manual Settings Page 7 (Ports 49~56) LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 There is no default setting. Page 8 (Ports 57~64) LK 1 LK 2 LK 3...
  • Page 448: Prime Line/Hot Line Assignment

    December 2004 NEC Business Solutions Ltd 4-23 Prime Line/Hot Line System Mode Assignment Submode — General Description Data No. Use this memory block to enable user to access various features when going off-hook. PC Programming Display Tel Port + BTT...
  • Page 449: Slt Hookflash Assignment

    Xen IPK Programming Manual 4-24 SLT Hookflash Assignment System Mode General Description Submode Use this memory block to specify the Single Line Telephone (SLT) hooking operation to either — Hold or disconnect the trunk. Data No. Display Tel Port PC Programming...
  • Page 450: Disa/Id Number Station Assignment

    December 2004 NEC Business Solutions Ltd 4-26 DISA/ID Number Station System Mode Assignment Submode — General Description Data No. Use this Memory Block to assign the Direct Inward System Access (DISA) ID Buffer Number corresponding to the station port number. The Station Message Detail Recording (SMDR) printout of the station number corresponds to the calling party who dialled the DISA ID number.
  • Page 451: Section 6 Code Restriction

    Xen IPK Programming Manual 4-27 ID Outgoing Restriction System Mode Selection Submode — General Description Data No. Use this Memory Block to specify which ID Numbers can be entered at each station to override Code Restriction. PC Programming Display + BTT...
  • Page 452 December 2004 NEC Business Solutions Ltd Settings Page 7 (ID No. 49) LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 Page 8 (ID No. 57) LK 1 LK 2 LK 3 LK 4...
  • Page 453 Xen IPK Programming Manual Programming Procedures Go off-line. Press LK4 + to access the Memory Block. Press the CO/PBX Line key corresponding to each CO/PBX number. Default Values All stations = Available for all ID The LED indication changes to indicate data each time a CO/PBX line key Numbers.
  • Page 454: Multilingual Lcd Indication Selection

    December 2004 NEC Business Solutions Ltd 4-28 Multilingual LCD Indication System Mode Selection Submode — General Description Data No. Use this Memory Block to specify whether Japanese, French, English or Spanish is displayed on the Multiline Terminal LCD. PC Programming...
  • Page 455: Hfu Selection

    Xen IPK Programming Manual 4-29 HFU Selection System Mode General Description Submode Use this memory block to enable/disable (per station) the built-in Handsfree operation of Multiline — terminals. Data No. Display Tel Port No. PC Programming (01~99) Data Setting A0~C0...
  • Page 456: Hold/Transfer Recall Display Selection

    December 2004 NEC Business Solutions Ltd 4-30 Hold/Transfer Recall Display System Mode Selection Submode — General Description Data No. Use this memory block to enable/disable the Hold Recall indication on the LCD. PC Programming Display Tel Port No. + BTM...
  • Page 457: Receiving Internal/All Call Page Selection

    Xen IPK Programming Manual 4-31 Receiving Internal/All Call System Mode Page Selection Submode — General Description Data No. Use this memory block to enable/disable (per station) receiving an Internal Zone or Internal All Zone Page. PC Programming Display + BTT Tel Port No.
  • Page 458: Trunk Digit Restriction

    December 2004 NEC Business Solutions Ltd 4-32 Trunk Digit Restriction System Mode General Description Submode Use this Memory Block to specify the maximum number of digits per station that can be dialled — while on any outside line. Data No.
  • Page 459: Voice Mail/Slt Selection

    Xen IPK Programming Manual 4-35 Voice Mail/SLT Selection System Mode General Description Submode Use this memory block to specify whether or not a Voice Mail system is interfaced with the — system for Single Line Telephone ports. Data No. Display PC Programming Tel Port No.
  • Page 460: Voice Prompt Selection

    December 2004 NEC Business Solutions Ltd 4-36 Voice Prompt Selection System Mode General Description Submode Use this memory block to specify, per station, whether to allow or deny Voice Prompt. — Data No. Display Tel Port No. PC Programming Data...
  • Page 461: Extension Line Key Ring Assignment (Day Mode)

    Xen IPK Programming Manual 4-37 4-37 Extension Line Key Ring System Mode System Mode Assignment (Day Mode) Submode Submode — — General Description Data No. Data No. Use this Memory Block to specify the ringing assignment on incoming calls to a Secondary Incoming Extension (SIE) or a Call Arrival key.
  • Page 462 December 2004 NEC Business Solutions Ltd Related Programming M.B. Number Memory Block Name 1-2-26 Delayed Ringing Timer Assignment (ICM) 1. When Ring is set, the LED is green. 2. This Memory Block applies only when an SIE or Call Arrival key is programmed for line key appearance.
  • Page 463: Extension Line Key Ring Assignment (Night Mode)

    Xen IPK Programming Manual 4-38 Extension Line Key Ring System Mode Assignment (Night Mode) Submode — General Description Data No. Use this Memory Block to specify the ringing assignment on incoming calls to a Secondary Incoming Extension (SIE) or a Call Arrival key.
  • Page 464 December 2004 NEC Business Solutions Ltd Programming Procedures (Continued) Press to write the data. Press to go back on-line. Related Programming M.B. Number Memory Block Name 1-2-26 Delayed Ringing Timer Assignment (ICM) 1. When Ring is set, the LED is green.
  • Page 465: Apr Ring Mode Assignment

    Xen IPK Programming Manual 4-39 APR Ring Mode Assignment System Mode General Description Submode Use this Memory Block to specify the ringing mode for an Single Line Telephone connected to — the APR-U. Data No. Display PC Programming Tel Port No.
  • Page 466: Lcr Class Selection

    System Mode General Description Submode Use this Memory Block to specify, per station, the Least Cost Routing (LCR) Class. The Xen IPK — has four Area Code Tables. Each LCR Class can have different Trunk Group access to allow Data No.
  • Page 467: Sie/Car Ringing Line Preference Selection

    Xen IPK Programming Manual 4-41 SIE/CAR Ringing Line System Mode Preference Selection Submode — General Description Data No. Use this Memory Block to specify whether to allow/deny Ringing Line Preference (go off-hook or press Speaker key) on all telephones that are assigned Secondary Incoming Extension (SIE) and/or Call Arrival keys.
  • Page 468: Call Forward-Busy Immediately/Delay Selection

    December 2004 NEC Business Solutions Ltd 4-42 Call Forward-Busy System Mode Immediately/Delay Selection Submode — General Description Data No. Use this Memory Block to specify immediate forward (No) or delay forward (Yes) for an Incoming CO/PBX call if the station is set for Call Forward Busy.
  • Page 469: Station To Call Appearance Block Assignment

    Xen IPK Programming Manual 4-43 Station to Call Appearance System Mode Block Assignment Submode — General Description Data No. Use this Memory Block to assign a Multiline Terminal to a Call Appearance Block. PC Programming Display Tel Port No. + BTT...
  • Page 470: Caller Id/Preset Dial Outgoing Co Selection

    December 2004 NEC Business Solutions Ltd 4-44 Caller ID/Preset Dial System Mode Outgoing CO Selection Submode — General Description Data No. Use this Memory Block to assign the Trunk Group, Route Advanced Group, or Closed Numbering Group that is seized for Caller ID Outgoing Calls and preset dial. Use the Caller ID Scroll key to access the Caller ID to be called.
  • Page 471: Live Record Auto Delete

    Xen IPK Programming Manual 4-46 Live Record Auto Delete System Mode General Description Submode This Memory Block controls whether live record sessions that are not addressed by the station — user are deleted or not. Data No. Display PC Programming Tel Port No.
  • Page 472: Isdn Directory Number Selection

    December 2004 NEC Business Solutions Ltd 4-47 ISDN Directory Number System Mode Selection Submode — General Description Data No. This Memory Block specifies whether or not the directory Number is presented to the Network when a call is placed from the programmed station.
  • Page 473 Xen IPK Programming Manual BRI: 1. When this Memory Block is set to No, the station placing an outgoing call does not present the programmed number in Memory Block 3-52 assigned for the BRI Trunks. The Network presents Restricted for the Caller ID information.
  • Page 474: Caller Id Display For Car Key

    December 2004 NEC Business Solutions Ltd 4-49 Caller ID Display for CAR Key System Mode General Description Submode This Memory Block assigns one Multiline Terminal per CAR to display Caller ID Indication on — incoming CAR calls. Data No. This memory block is not applicable to IPK R2000 and above.
  • Page 475: Multiline Terminal Type Selection

    Xen IPK Programming Manual 4-50 Multiline Terminal Type System Mode Selection Submode — General Description Data No. This Memory Block is used to assign a DTU-32D-1A (BK)/(WH), or DTR-32D-1A (BK)/(WH) TEL with 16 line keys or 24 line keys. PC Programming...
  • Page 476 December 2004 NEC Business Solutions Ltd Telephone ports A0~C0 are ports 100~120. Line Key Orientation LK = Line Keys OT = One-Touch DTUD-32D-1A TEL Keys 16 Line Key Type 24 Line Key Type OT 1 OT 9 LK17 LK21 OT 2...
  • Page 477: Off-Hook Ringing Selection

    Xen IPK Programming Manual 4-51 Off-Hook Ringing Selection System Mode General Description Submode Use this Memory Block to assign Off-Hook Ringing to Multiline Terminals per station. — Data No. Display Tel Port No. PC Programming Data Setting (01~99) Title Data...
  • Page 478: Co/Pbx Answer Key Operation Without Ringing Assignment (Day Mode)

    December 2004 NEC Business Solutions Ltd 4-52 CO/PBX Answer Key System Mode Operation without Ringing Submode Assignment (Day Mode) — Data No. General Description PC Programming This Memory Block is used to disable Ring Assigned telephones from ringing during Day and allowing Message Waiting and Answer Key to blink, therefore allowing calls to be answered.
  • Page 479: Co/Pbx Answer Key Operation With-Out Ringing Assignment (Night Mode)

    Xen IPK Programming Manual 4-53 CO/PBX Answer Key System Mode Operation with-out Ringing Submode Assignment (Night Mode) — Data No. General Description PC Programming This Memory Block is used to disable Ring Assigned telephones from ringing during Night and allowing Message Waiting and Answer Key to blink, therefore allowing calls to be answered.
  • Page 480: Co Ringing Pattern Selection For Telephone Mode

    December 2004 NEC Business Solutions Ltd 4-55 CO Ringing Pattern Selection System Mode for Telephone Mode Submode — Use this Memory Block to assign the ring pattern of telephones for CO/PBX calls. Data No. Display Tel Port PC Programming Data...
  • Page 481 Xen IPK Programming Manual This memory block is controlled by MB 4-57 if calls are to be CO or Telephone ring. The Ring Patterns are shown in the table below: s= seconds Pattern No Ring DRAFT 3 4-55, CO Ringing Pattern Selection for Telephone Mode...
  • Page 482: Smdr Telephone Print Selection

    December 2004 NEC Business Solutions Ltd 4-56 SMDR Telephone Print System Mode Selection Submode — General Description Data No. Use this memory block to enable/disable (per station) SMDR print-out after finishing CO/ PBX call. PC Programming Display + AS Tel Port No.
  • Page 483: Co Line Ringing Pattern By Telephone Or Co Selection

    Xen IPK Programming Manual 4-57 CO Line Ringing Pattern by System Mode Telephone or CO Selection Submode — General Description Data No. Use this memory block to select if CO or Telephone is to have ring pattern. PC Programming Display...
  • Page 484: Automated Attendant Did Assignment

    December 2004 NEC Business Solutions Ltd 4-58 Automated Attendant DID System Mode Assignment Submode — General Description Data No. Use this Memory Block to determine the action after a DID call arrives at an extension or CAR, and is not answered after predetermined time.
  • Page 485: Apr Hookflash Selection

    Xen IPK Programming Manual 4-59 APR Hookflash Selection System Mode General Description Submode Use this Memory Block to allow/deny Hookflash for an Analogue Port Adapter (APR) on a — Multiline Terminal. Data No. Display Tel Port PC Programming Data Setting...
  • Page 486: Station Name/Number Display Selection

    December 2004 NEC Business Solutions Ltd 4-61 Station Name/Number Display System Mode Selection Submode — General Description Use this Memory Block to specify whether the station name and/or station number shall be displayed on an idle Multiline telephone’s LCD. PC Programming...
  • Page 487: Isdn Extension-Based Caller Id Assignment

    Xen IPK Programming Manual 4-62 ISDN Extension-based Caller System Mode ID Assignment Submode — General Description Data No. This Memory Block provides the station DID Number (CPN, Calling Party Number) to the Network when placing outgoing calls. PC Programming Display + BTT Tel Port No.
  • Page 488: Timer Class Assignment For Telephone Mode Selection

    December 2004 NEC Business Solutions Ltd 4-64 Timer Class Assignment for Submode Telephone Mode Selection System Mode — General Description Data No. This Memory Block assigns class of flexible timer to Extenstions. Applicable to IPK R2000. PC Programming Display + BTT Tel Port No.
  • Page 489 Xen IPK Programming Manual Related Programming (Continued) 1-2-02 Automatic Callback Release Timer Selection 1-2-22 Call Forward No Answer Timer Selection 1-2-23 System Call Park Recall Time Selection 1-3-03 First Digit PBR Release Timer Selection 1-4-01 Automated Attendant First Digit PBR Release Timer Selection...
  • Page 490: Code Restriction Class Assignment Cfva Restricted Tel/Night Mode

    December 2004 NEC Business Solutions Ltd 4-65 Code Restriction Class Submode Assignment CFVA Restricted System Mode Tel/Night Mode — Data No. General Description PC Programming This Memory Block assigns class table for dialling restriction when using Trunk Route or Route Advance access code.
  • Page 491: Acd Plus Hold Tone Selection

    Xen IPK Programming Manual 4-66 ACD Plus Hold Tone Selection Submode General Description System Mode Use this Memory Block to select the Hold Tone for ACD Plus. — Data No. Display Tel Port No. PC Programming Data Setting (01~99) Title...
  • Page 492: Ip Station Number Assignment

    December 2004 NEC Business Solutions Ltd 4-67 IP Station Number System Mode Assignment Submode — General Description Data No. Use this Memory Block to assign a station number for each IP telephone supported by the IPCA( )-U( ) ETU PC Programming...
  • Page 493: Lcd Line Key – Name Assignment

    Xen IPK Programming Manual 4-68 LCD Line Key – Name System Mode Assignment Submode — General Description Data No. Use this Memory Block to assign a name to each LCD Line Key of the DTR-16LD-1 Telephone. Up to eight characters can be assigned...
  • Page 494 December 2004 NEC Business Solutions Ltd LK Assign Default Note NON (not assigned) All Blank CO Outside Lines CO^xx xx=Port 01~64 Call Forward – Busy/No Answer Call Forward – All Calls xx=Block 00~47 Call Appearance Keys (CAP) CAPxx-yy yy=Key 01~24...
  • Page 495: Slt Data Line Security Assignment

    Xen IPK Programming Manual 4-90 SLT Data Line Security System Mode Assignment Submode — General Description Data No. Use this Memory Block to specify Normal/Data position for Single Line Telephones (SLTs). PC Programming Display Tel Port No. + BTT (01~99)
  • Page 496: Telephone Ringing Variation Selection

    December 2004 NEC Business Solutions Ltd 4-91 Telephone Ringing Variation System Mode Selection Submode — General Description Data No. Use this Memory Block to assign a Low, Medium, or High ringing tone frequency if Telephone is specified in Memory Block, 1-1-28 , Distinctive Ringing by Telephone or CO Selection.
  • Page 497: Receiving Volume Selection

    Xen IPK Programming Manual 4-92 Receiving Volume Selection System Mode General Description Submode Use this Memory Block to specify whether receiving volume is returned to normal (DOWN) or — kept as is (UP) on a call after hanging up. Data No.
  • Page 498: Internal Zone Paging Selection

    December 2004 NEC Business Solutions Ltd 4-93 Internal Zone Paging System Mode Selection Submode — General Description Data No. Use this Memory Block to place stations in Internal page zones. PC Programming Display Tel Port No. + BTM Data Setting...
  • Page 499: Minute Alarm Selection

    Xen IPK Programming Manual 4-94 3-Minute Alarm Selection System Mode General Description Submode Use this Memory Block to specify, per station, whether or not a warning signal tone is generated — at 3-minute intervals during an outgoing or incoming CO/PBX call.
  • Page 500: Dtmf/Dp Slt Type Selection

    December 2004 NEC Business Solutions Ltd 4-95 DTMF/DP SLT Type System Mode Selection Submode — General Description Data No. Use this Memory Block to specify, per port, whether Dial Pulse or Dual-Tone Multifrequency Single Line Telephone is connected to the system.
  • Page 501: Digit Add/Del For Tie Line Networking

    Xen IPK Programming Manual 5-00 Digit Add/Del for Tie Line System Mode Networking Submode — General Description Data No. Use this Memory Block to specify the number of digits to be added to and/or deleted from the telephone number sent from a distant system over Tie lines or from DID lines. The digits enable the system to determine whether a call is directed to itself (local) or to another system (distant).
  • Page 502 December 2004 NEC Business Solutions Ltd Related Programming M.B. Number Memory Block Name 1-1-46 Access Code (1-Digit) Assignment 3-03 Trunk-to-Trunk Group Assignment 1. This Memory Block applies only when two or more systems are connected by Tie lines or when the systems are connected by a DID line.
  • Page 503: Tie Line Networking Tandem Connection Assignment

    Xen IPK Programming Manual 5-01 Tie Line Networking Tandem System Mode Connection Assignment Submode — General Description Data No. Use this Memory Block to specify whether or not Trunk Groups connected to the system allow incoming Trunk Groups to be connected to outgoing Trunk Groups for tandem connections.
  • Page 504 December 2004 NEC Business Solutions Ltd Programming Procedures Go off-line. Press LK5 + to access the Memory Block. Press the corresponding CO/PBX line key to change the data option. Operation data includes: CO/PBX Line LED There is no default setting.
  • Page 505: Digit Matching Table To Trunk Group Assignment

    Xen IPK Programming Manual 5-02 8-Digit Matching Table to System Mode Trunk Group Assignment Submode — General Description Data No. Use this Memory Block to assign each Trunk Group to the 8-Digit Matching Tables. PC Programming Display Trunk Group Page...
  • Page 506: Occ Table To Trunk Group Assignment

    December 2004 NEC Business Solutions Ltd 5-03 OCC Table to Trunk Group System Mode Assignment Submode — General Description Data No. Use this Memory Block to assign each of the 16 OCC Tables to each Trunk Group. PC Programming Display Trunk Group No.
  • Page 507: Lcr Class To Trunk Group Selection

    Xen IPK Programming Manual 5-04 LCR Class to Trunk Group System Mode Selection Submode — General Description Data No. Use this Memory Block per trunk group to specify the Least Cost Routing (LCR)/Automatic Carrier Routing (ACR) Class. For systems connected using K-CCIS, the Electra Elite can...
  • Page 508 December 2004 NEC Business Solutions Ltd Related Programming (Continued) M.B. Number Memory Block Name 1-15-09 K-CCIS Maximum Call Forwarding Hop Assignment 1-15-10 Calling Name Display Allow/Deny Selection 5-05 Common Signalling Channel Route Selection Refer to the Electra Elite IPK Key-Common Channel Interoffice Signalling (K-CCIS) Manual for details.
  • Page 509: Common Signalling Channel Route Assignment

    Xen IPK Programming Manual 5-05 Common Signalling Channel System Mode Route Assignment Submode — General Description Data No. Use this Memory Block to specify the Common Signalling Channel for each voice trunk group used for K-CCIS PC Programming Applicable for IPK R2000 and above.
  • Page 510 December 2004 NEC Business Solutions Ltd Related Programming (Continued) M.B. Number Memory Block Name 1-15-09 K-CCIS Maximum Call Forwarding Hop Assignment 1-15-10 Calling Name Display Allow/Deny Selection LCR Class to Trunk Group Selection This Memory Block is used to assign the voice channels to the Common Channel. When the voice channels trunk group is set at 0, K-CCIS does not operate correctly.
  • Page 511: Trunk Group Outgoing Priority Selection

    Xen IPK Programming Manual 5-06 Trunk Group Outgoing System Mode Priority Selection Submode — General Description Data No. Use this Memory Block to assign the Outgoing Priority for trunk access to each Trunk Group. This is normally used with a Tie Line or K-CCIS network to reverse the search order...
  • Page 512 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 492 – Chapter 1 Trunk Group Outgoing Priority Selection, 5-06...
  • Page 513: Tenant Mode Copy Assignment

    Xen IPK Programming Manual Tenant Mode Copy System Mode Assignment Submode General Description Data No. Use this Memory Block to enable copying data from one tenant to another tenant or multiple consecutive tenants. — Display Setting Title Data ‡ T N A T —...
  • Page 514 December 2004 NEC Business Solutions Ltd Enter the beginning of the tenant (00~47) range to be copied to. Using the dial pad, press KE . Setting Title Data — — T N A T 0 5 — T I M E D I S P L A Y Enter the end of the tenant (00~47) range to be copied to.
  • Page 515: Co Line Mode Copy Assignment

    Xen IPK Programming Manual CO Line Mode Copy System Mode Assignment Submode General Description Data No. Use this Memory Block to enable copying data from one CO/PBX line to another CO/PBX line or multiple consecutive CO/PBX lines. — Display Setting...
  • Page 516 December 2004 NEC Business Solutions Ltd Enter the beginning of the CO/PBX (02~64) range to be copied to. Using the dial pad, press KE . Setting Data Title — — 0 5 — T I M E D I S P L A Y Enter the end of the CO/PBX (02~64) range to be copied to.
  • Page 517: Telephone Mode Copy Assignment

    Xen IPK Programming Manual Telephone Mode Copy Assignment Submode Data No. General Description — Use this Memory Block to enable copying data from one telephone port to another telephone port or multiple consecutive telephone ports. Display Setting Title Data T E L —...
  • Page 518 December 2004 NEC Business Solutions Ltd Enter the beginning of the Tel. Port No. (01~C0) range to be copied to. Using the dial pad, press BK . Setting Title Data — — T E L 2 0 — T I M E D I S P L A Y Enter the end of the Tel.
  • Page 519: Trunk Group Mode Copy Assignment

    Xen IPK Programming Manual Trunk Group Mode Copy System Mode Assignment Trunk Group General Description Use this Memory Block to enable copying data from one Trunk Group to another Trunk Group or Data No. multiple consecutive Trunk Groups. — Display...
  • Page 520 December 2004 NEC Business Solutions Ltd Enter the Start Trunk Group No. (01~32). Using the dial pad, press AK . Setting Title Data — — T R K 1 0 — T I M E D I S P L A Y Enter the End Trunk Group (01~32).
  • Page 521: Card Interface Slot Assignment

    Xen IPK Programming Manual Card Interface Slot System Mode Assignment Submode General Description Data No. Use this Memory Block to specify the type of installed ETUs. — PC Programming Display Port Number for COI 4, TLI, DID, SLI 4, OPX, DPH, VRS, VMS 2/4 ETU...
  • Page 522 December 2004 NEC Business Solutions Ltd Programming Procedures Go off-line. Press LK7 + LK1 to access the Memory Block. Use the Line key to enter setting data. Page 2 Page 1 Line Line Setting Data LCD Indication Setting Data LCD Indication...
  • Page 523 Xen IPK Programming Manual Programming Procedures (Continued) Use the Line Key to enter Setting Data. Page 2 Page 1 Line Line Setting Data LCD Indication Setting Data LCD Indication DT14 ESIB(8)-U( ) ESIB8 DT18 ESIE(8)-U( ) ESIB16 DTI12 MG(8)-U( )
  • Page 524 December 2004 NEC Business Solutions Ltd KSU Power-Based ETU Quantity Limitations The following charts indicate the maximum number of specific ETU combinations in each KSU that are restricted by power limitations of the KSU. For System without Xen VP/CTI Either Maximum NO.
  • Page 525 Xen IPK Programming Manual Card Interface Slot Assignment PORT No. Basic KTU SLOT 1~8 SLOT 1, A (Refer to 1) EXP KTU SLOT 1~8 BRT(4)-U( ) BSU(2)-U( ) CCH(4)-U( ) COI(4)-U( ) COI(8)-U( ) COID(4)-U( ) COID(8)-U( ) DID(4)-U( ) DPH(4)-U( ) —...
  • Page 526 December 2004 NEC Business Solutions Ltd 1 C: Port Number of CO/PBX Line Telephone Port Number (smallest number is displayed) Voice Recording Service Package –: No Display BSU No. CCH No. HUB No. Enabled Space: Disabled Related Programming M.B. Number...
  • Page 527: Telephone Type Assignment

    Xen IPK Programming Manual Telephone Type Assignment System Mode General Description Telephone Use this Memory Block to specify the type of device that is connected to an ESI port. Data No. Display — Port No. PC Programming (01~96) Setting Data...
  • Page 528: Mif (Acd) Assignment

    December 2004 NEC Business Solutions Ltd 7-3-00 MIF (ACD) Assignment System Mode General Description Use this Memory Block to enable the Automatic Call Distribution (ACD) function of the MIFA- U( ) ETU. Data No. Display Setting PC Programming Data Data...
  • Page 529: Mif (Lcr) Assignment

    Xen IPK Programming Manual 7-3-01 MIF (LCR) Assignment System Mode General Description Use this Memory Block to enable the Least Cost Routing (LCR) function of the MIFM-U( ) ETU. Data No. Display Setting Data Title Data PC Programming 0 1 : L C R...
  • Page 530: Mif (Smdr) Assignment

    December 2004 NEC Business Solutions Ltd 7-3-02 MIF (SMDR) Assignment System Mode General Description Use this Memory Block to enable the Station Message Detail Reporting (SMDR) function on the MIFM-U( ) ETU. Data No. Display Setting Data PC Programming Data...
  • Page 531: Mif (Ucd) Assignment

    Xen IPK Programming Manual 7-3-03 MIF (UCD) Assignment System Mode General Description Use this Memory Block to enable the Uniform Call Distribution (UCD) function on the MIFA- U( ) ETU. Data No. Display Data PC Programming Title Setting Data + BS...
  • Page 532: Mif (Caller Id) Assignment

    December 2004 NEC Business Solutions Ltd 7-3-04 MIF (Caller ID) Assignment System Mode General Description Use this Memory Block to enable the Caller ID scrolling or outdial function on the MIFM-U( ) ETU. Basic Caller ID works without an MIFM-U( ) ETU installed.
  • Page 533: Rom Version Confirmation

    Xen IPK Programming Manual ROM Version Confirmation System Mode General Description Use this Memory Block to confirm the program version without removing the card from the KSU. Data No. Display — Software Package Name ROM Version PC Programming S P 1 7 7...
  • Page 534 December 2004 NEC Business Solutions Ltd Programming Procedures (Continued) Frame number, slot number, interface name, and ROM Version are shown on the display. There are three display patterns. 1) For basic frame (frame 1 or slot C) CPU: S P 6 0...
  • Page 535: System Speed Dial Memory Clear

    Xen IPK Programming Manual System Speed Dial Memory System Mode Clear Spd-Clr-Sys General Description Data No. Use this Memory Block to clear all System Speed Dial programming. — PC Programming Before programming this procedure, please ensure you understand completely the + BE affect of erasing all System Speed Dial buffers in the system.
  • Page 536: Station Speed Dial Memory Clear

    December 2004 NEC Business Solutions Ltd Station Speed Dial Memory System Mode Clear Spd-Clr-Sta Use this Memory Block to clear the Station Speed Dial memories of all programmed Speed Data No. Dial numbers. — PC Programming Before programming this procedure, please ensure you understand completely the affect of erasing all Station Speed Dial buffers in the system.
  • Page 537: Second Initialisation

    Xen IPK Programming Manual 8-8-8800 Second Initialisation System Mode General Description CO-Line Use this Memory Block to initialise all the system hardware. All system software and user programming are retained after the Second Initialisation. Data No. 8800 Display PC Programming...
  • Page 538: Clock/Calendar Setting

    December 2004 NEC Business Solutions Ltd — Clock/Calendar Setting System Mode — General Description Data No. This Memory Block is used to set the time and date that are displayed on the Multiline Terminals. — Submode Display — 1 1 : 0 8 A M PC Programming —...
  • Page 539 Xen IPK Programming Manual Press 1 2 : 0 0 P M T I M E D I S P L A Y Press M O N J A N 2 0 0 3 T I M E D I S P L A Y Press until SUN is displayed.
  • Page 540 December 2004 NEC Business Solutions Ltd THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 520 – Chapter 1 Clock/Calendar Setting, —...
  • Page 541: Function Timer Chart

    Xen IPK Programming Manual SECTION 5 The chart on the following pages provides a list of timers that can be programmed in the system. The information is listed numerically by Memory FUNCTION TIMER Block number. A brief definition and the timing value is given for each timer.
  • Page 542 NEC Business Solutions Ltd December 2004 Function Timer Chart (Continued) Table 1-3: Timing Value Memory Timer Definition Block Minimum Default Maximum Hold Recall Time Specify the time for Exclusive Hold 1-1-63 30 sec. 1 min. No Limit Selection Recall. (Exclusive)
  • Page 543 Xen IPK Programming Manual Function Timer Chart (Continued) Table 1-3: Timing Value Memory Timer Definition Block Minimum Default Maximum Delayed Ringing Specify the time for delayed 1-2-26 0 sec. 10 sec. 99 sec. Timer Assignment ringing on internal calls. (ICM)
  • Page 544 NEC Business Solutions Ltd December 2004 Function Timer Chart (Continued) Table 1-3: Timing Value Memory Timer Definition Block Minimum Default Maximum Automated Specify the time for a No Answer 1-4-02 10 sec. No Limit No Limit Attendant Transfer at the transferred station before...
  • Page 545 Xen IPK Programming Manual Function Timer Chart (Continued) Table 1-3: Timing Value Memory Timer Definition Block Minimum Default Maximum PBR Interdigit Specify the interdigit release time 1-8-10 3 sec. 7 sec. 10 sec. Release Timer for the PBR. Selection System Refresh Assign the system refresh time.
  • Page 546 NEC Business Solutions Ltd December 2004 Function Timer Chart (Continued) Table 1-3: Timing Value Memory Timer Definition Block Minimum Default Maximum Tie Line Length of Specify the time a delay pulse is 3-22 0 ms. 300 ms. 4500 ms. Delay Signal sent to another system.
  • Page 547: Code Restriction

    Xen IPK Programming Manual SECTION 6 General CODE The Xen systems provide an advanced method of restricting outgoing calls based on the first eight digits dialled. Code Restriction denies placement of RESTRICTION outside calls based on Trunk groups and accommodates equal access to other common carriers (OCC).
  • Page 548 NEC Business Solutions Ltd December 2004 Memory Blocks The following related Memory Blocks are used when assigning Code Restriction. Title Memory Block Trunk to Tenant Assignment 2-01 Trunk-to-Trunk Group Assignment 3-03 Trunk Type Selection 3-91 PBX/CTX Access Code Assignment I...
  • Page 549: Occ Table Assignment

    Xen IPK Programming Manual 6.4.2 OCC Assignment/Operation OCC Table Assignment (Memory Block 1-1-67) This Memory Block allows an OCC Access Code (maximum of eight digits) to be assigned. System Programming has 16 OCC Tables (01~16). Each table can have one OCC Access Code assigned.
  • Page 550 NEC Business Solutions Ltd December 2004 8-Digit Matching Table Assignment (Memory Block 1-1-60) This Memory Block assigns the 8-Digit Matching Tables. Each 8-Digit Matching Table can have sixteen 8-digit entries. To cover the many possible combinations (without listing each individual number), code restriction letters can be used in place of digits.
  • Page 551: System Speed Dial Override By Class Selection

    Xen IPK Programming Manual If a match is found, the system looks at the 8-Digit Matching Table to Class Assignment for the Allow or Deny Assignment. If the table is assigned as Allow, the call is allowed. If the table is assigned as Deny, the call is denied.
  • Page 552: Code Restriction Class Assignment (Day Mode)

    NEC Business Solutions Ltd December 2004 6.4.9 Code Restriction Class Assignment (Day Mode) (Memory Block 4-07) This Memory Block specifies, per station, the Code Restriction Class used when the system or stations assigned tenant is in the Day Mode. 6.4.10...
  • Page 553 Xen IPK Programming Manual Table 01 Table 02 Table 03 Table 04 Memory Block (1-1-67) Memory Block (5-03) Trunk Group 01~32 Trunk Group 01~32 Trunk Group 01~32 Trunk Group 01~32 Memory Block (1-1-68) Table 05 Table 06 Table 07 Table 08...
  • Page 554 NEC Business Solutions Ltd December 2004 6.5.2 8-Digit Matching Tables with Default Values The following Memory Blocks are displayed: 8-Digit Matching Table to Normal Dial Assignment (1-1-66) 8-Digit Matching Table to Trunk Group Assignment (5-02) 8-Digit Matching Table Assignment (1-1-60)
  • Page 555 Xen IPK Programming Manual 8-Digit Matching Table to Normal Dial Assignment (1-1-66) 8-Digit Matching Table to Trunk Group Assignment (5-02) 8-Digit Matching Table Assignment (1-1-60) Table 04 Table 05 Table 06 Table 07 Memory Block (1-1-66) Use Table Use Table...
  • Page 556 NEC Business Solutions Ltd December 2004 8-Digit Matching Table to Normal Dial Assignment (1-1-66) 8-Digit Matching Table to Trunk Group Assignment (5-02) 8-Digit Matching Table Assignment (1-1-60) Table 08 Table 09 Table 10 Table 11 Memory Block (1-1-66) Use Table...
  • Page 557 Xen IPK Programming Manual 8-Digit Matching Table to Normal Dial Assignment (1-1-66) 8-Digit Matching Table to Trunk Group Assignment (5-02) 8-Digit Matching Table Assignment (1-1-60) Table 12 Table 13 Table 14 Table 15 Memory Block (1-1-66) Use Table Use Table...
  • Page 558 NEC Business Solutions Ltd December 2004 8-Digit Matching Tables with Default Values The following designations are used in this table: 8-Digit Matching Table to Class Assignment (1-1-61) Class Allow/Deny Selection (1-1-65) 8-Digit Matching Table Class Allow/Deny 01 02 03 04 05 06 07 08 09 10 11...
  • Page 559 Xen IPK Programming Manual Code Restriction Algorithm The following chart identifies how the system checks for and processes Code Restriction assignments. User Accesses a CO/PBX Line Code Restriction Class Disconnect Class 00 Class 15 Allow User (Day, Night) Issue Error Free M.
  • Page 560 NEC Business Solutions Ltd December 2004 Search 8-Digit Matching Table From Table 00~15 After Each Digit Entered For First 8 Digits Search Only 8-digit Matching Tables Assigned To Class Assignment M. B. 1-1-61 Search Only 8-Digit Matching Tables Assigned to OCC Table M.
  • Page 561: System Data Input

    Xen IPK Programming Manual SECTION 7 The character code tables are used when entering some of the functions provided with the Xen system. CHARACTER CODE TABLES For Key Pad entry refer to 7.1 Dial Pad Character Assignment. Codes 166~221 and 250~252 are used for Japanese characters only.
  • Page 562: Speed Dial Name Input

    NEC Business Solutions Ltd December 2004 7.1.1 Trunk name or Number Assignment Example (DNIS assignment uses this character dial pad.) 1. Enter Program Mode. Display shows PROGRAM MODE. 2. Press LK3. Display shows 01/_ 3. Press LK2 Display still shows 01/_ 4.
  • Page 563 Xen IPK Programming Manual 7.1.1 Enter Speed Dial Name 1. Press inactive Display is blank. 2. Press Display shows_: 3. Press Display shows 00:_ 4. Press Display shows 00:0:_ 5. Press ABCDE Display shows 00:0:12345_. 6. Press Display shows 00=_ 7.
  • Page 564: Abbreviations Used In Multiline Terminal Displays

    NEC Business Solutions Ltd December 2004 SECTION 8 Abbreviations found in the display are defined in below. DISPLAY Abbreviations Used in Multiline Terminal Displays Table 1-6: ABBREVIATIONS ADD/DEL Addition/Deletion External Speaker FWDG Forwarding Alarm FLSH Flash Answer GUARD Outgoing Guard Time...
  • Page 565 Xen IPK Programming Manual Abbreviations Used in Multiline Terminal Displays (Continued) Table 1-6: RNGTON Day Mode Ringing Tone PAD Pattern A PAD AT Transmission Route Assignment PAD Pattern A PAD AR Receiving RT ADV Route Advance Block Assignment PAD Pattern B...
  • Page 566 NEC Business Solutions Ltd December 2004 THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 546 – Chapter 1 Section 6, Code Restriction...
  • Page 567: Section 1 General Information

    Programming Chapter 2 SECTION 1 This chapter provides a roadmap for programming the features for the Xen IPK systems. The Programming Xen IPK System Guide Tables provide GENERAL information helpful to the technician when programming the systems. INFORMATION SECTION 2 The tables provided in this section are useful as a quick reference when programming the Xen system.
  • Page 568: Account Code Entry

    NEC Business Solutions Ltd December 2004 Account Code Entry Menu Access System Data Name Memory Block Keyboard Shortcut Start Timer Selection 1-1-05 Access Code (1-, 2-, or 3-Digit Assignment) 1-1-46/47/48 Printer Connected Selection 1-5-13 SMDR Valid Call Timer Assignment 1-5-25...
  • Page 569: All Call Page

    Xen IPK Programming Manual Account Code Forced/Verified Menu Access System Data Name Memory Block Keyboard Shortcut Access Code (1-, 2-, or 3-Digit) Assignment 1-1-46/47/48 +BTS Class of Service (Attendant) Feature Selection 1 1-8-07 1-8-08 +BTS Class of Service (Station) Feature Selection 2 (Pg.
  • Page 570: Alphanumeric Display

    NEC Business Solutions Ltd December 2004 Alphanumeric Display Menu Access System Data Name Memory Block Keyboard Shortcut Speed Dial Number/Name Display Selection 1-1-33 Customised Message 1~10 Assignment 1-2-09~18 +BCT Trunk Name/Number Assignment 3-00 +BTT Station Name Assignment 4-18 +BTM Multilingual LCD Indication Selection...
  • Page 571 Xen IPK Programming Manual Answer Key (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +BTT CO/PBX Ring Assignment (Day Mode) 4-01 +BTT CO/PBX Ring Assignment (Night Mode) 4-02 +BTM Ringing Line Preference Selection 4-11 CO/PBX Answer Key Operation without Ringing (Day...
  • Page 572: Attendant Positions

    NEC Business Solutions Ltd December 2004 Attendant Camp-On Menu Access System Data Name Memory Block Keyboard Shortcut +BTS System Transfer/Camp-On Selection 1-1-11 Attendant Add-On Console Transfer/Camp-On Recall Timer 1-1-64 Selection +BTS Class of Service (Station) Feature Selection 2 1-8-08 +BTT...
  • Page 573: Automated Attendant

    Xen IPK Programming Manual Automated Attendant Menu Access System Data Name Memory Block Keyboard Shortcut 1-1-46/47/48 Access Code (1-, 2-, or 3-Digit) Assignment (Item 501) Automated Attendant Transfer Ring Pattern 1-1-54 Specified Station Access Code Assignment 1-2-08 Automated Attendant First Digit PBR Release Timer...
  • Page 574: Automatic Callback

    NEC Business Solutions Ltd December 2004 Automated Attendant Menu Access System Data Name Memory Block Keyboard Shortcut 1-8-15 Tone Assignment (Table 1) +BCT Trunk Incoming Answer Mode Selection 3-05 Automated Attendant Message to Trunk Selection 3-38 +BTT CO/PBX Ring Assignment (Day Mode)
  • Page 575 Xen IPK Programming Manual Automatic Call Distribution (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +BCT Polarity Reverse Selection 3-90 +BTM Line Key Selection for Telephone Mode 4-12 Card Interface Slot Assignment MIF (ACD) Assignment 7-3-00 Refer to Delay Announcement on page 2566.
  • Page 576: Automatic Hold

    NEC Business Solutions Ltd December 2004 Automatic Day/Night Mode Switching Menu Access System Data Name Memory Block Keyboard Shortcut Automatic Day/Night Mode Switching Time Assignment 1-1-27 Automatic Day/Night Mode by Day of Week Selection 1-1-32 +BTS Class of Service (Attendant) Feature Selection 1...
  • Page 577: Automatic Redial

    Xen IPK Programming Manual Automatic Redial Menu Access Keyboard System Data Name Memory Block Shortcut Automatic Redial Time Selection 1-1-04 Menu Access System Data Name Memory Block Keyboard Shortcut +BCT Polarity Reverse Selection 3-39 Automatic Trunk-to-Trunk Transfer Menu Access System Data Name...
  • Page 578: Call Alert Notification

    NEC Business Solutions Ltd December 2004 Barge-In (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +BTT SLT Data Line Security Assignment 4-90 Busy Lamp Field on Multiline Terminals Menu Access System Data Name Memory Block Keyboard Shortcut Speed Dial Buffer Allocation...
  • Page 579: Callback Request

    Xen IPK Programming Manual Call Arrival Keys Menu Access System Data Name Memory Block Keyboard Shortcut Access Code (1-, 2-, or 3-Digit) Assignment 1-1-46/47/48 Call Arrival Key Block Assignment 1-2-04 +BTD Attendant Add-On Console Key Selection 1-6-05 Line Key Selection...
  • Page 580 NEC Business Solutions Ltd December 2004 Caller ID Indication (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +BTT CO/PBX Ring Assignment (Day Mode) 4-01 +BTT CO/PBX Ring Assignment (Night Mode) 4-02 +BTM Line Key Selection for Telephone Mode...
  • Page 581: Call Pickup Direct

    Xen IPK Programming Manual Call Forward – Off-Premise (MLT/SLT & CAR) Menu Access System Data Name Memory Block Keyboard Shortcut Access Code (1-, 2-, or 3-Digit) Assignment 1-1-46/47/48 Tandem Transfer Automatic Disconnect Timer Selection 1-4-00 1-8-07 +BTS *Class of Service (Attendant) Feature Selection 1 (Pg.
  • Page 582: Call Pickup Group

    NEC Business Solutions Ltd December 2004 Call Pickup Tenant Menu Access System Data Name Memory Block Keyboard Shortcut Access Code (1-, 2-, or 3-Digit) Assignment 1-1-46/47/48 Trunk to Tenant Assignment 2-01 +BTT Telephone to Tenant Assignment 4-09 Call Pickup Group...
  • Page 583: Class Of Service

    Xen IPK Programming Manual Centralised Voice Mail Menu Access System Data Name Memory Block Keyboard Shortcut +BTI Voice Mail/SLT Selection 4-35 +ALN Tie Line Networking Tandem Connection Assignment 5-01 Card Interface Slot Assignment Telephone Type Assignment Class of Service Menu Access...
  • Page 584 NEC Business Solutions Ltd December 2004 Code Restriction (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut System Speed Dial Override by Class Selection 1-1-62 Code Restriction Class Allow/Deny Selection 1-1-65 8-Digit Matching Table to Normal Dial Assignment 1-1-66...
  • Page 585: Cordless Telephone Connection

    Xen IPK Programming Manual CO/PBX Tie Line Digit Restriction Menu Access System Data Name Memory Block Keyboard Shortcut +BTT Trunk Digit Restriction 4-32 Refer to E & M Tie Lines (4-Wire) on page 2573 and to Code Restriction on page 1-563.
  • Page 586: Delayed Ringing

    NEC Business Solutions Ltd December 2004 Delay Announcement Menu Access System Data Name Memory Block Keyboard Shortcut 1-1-46/47/48 Access Code (1-, 2-, 3-Digit) Assignment (Item 501) First Delay Announcement Start Time Selection 1-1-71 First Delay Announcement Repeat Selection 1-1-72 First to Second Delay Announcement Interval Time Selection...
  • Page 587 Xen IPK Programming Manual Dial 9 for Attendant Menu Access System Data Name Memory Block Keyboard Shortcut Access Code (1-Digit) Assignment 1-1-46 Specified Station Access Code Assignment 1-2-08 +BTS Class of Service (Attendant) Feature Selection 1 1-8-07 +BTT Station to Class of Service Feature Assignment...
  • Page 588: Digital Voice Mail

    NEC Business Solutions Ltd December 2004 Digital Voice Mail Menu Access System Data Name Memory Block Keyboard Shortcut +BTD Attendant Add-On Console Key Selection 1-6-05 1-8-08 +BTS Class of Service (Station) Feature Selection 2 (Pg.4, LK5 & LK6) Line Key Selection for Tenant Mode...
  • Page 589 Xen IPK Programming Manual Direct Inward Dialling (DID) (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +ALT Trunk Type Selection 3-91 +ALN Digit Add/Delete for Tie Line Networking 5-00 Card Interface Slot Assignment Direct Inward System Access (DISA) without VRS Message...
  • Page 590 NEC Business Solutions Ltd December 2004 Direct Inward System Access (DISA) with VRS Message Menu Access System Data Name Memory Block Keyboard Shortcut 1-1-46/47/48 Access Code (1-, 2-, or 3-Digit) Assignment (Items 251, 252, 253, and 501) Automated Attendant First Digit PBR Release Timer...
  • Page 591: Direct Inward Termination

    Xen IPK Programming Manual Direct Inward Termination Menu Access System Data Name Memory Block Keyboard Shortcut Call Forward No Answer Timer Selection 1-2-22 +BCT DIT Assignment 3-42 +BCT ANA Assignment 3-43 Call Forward – Busy Immediately/Delay Selection 4-42 +BTT Direct Paging Access...
  • Page 592: Do Not Disturb

    NEC Business Solutions Ltd December 2004 Distinctive Ringing (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +ALN Tie Line Delay Ring Pattern Selection 1-1-53 +BCS Synchronous Ringing Selection 1-1-59 +BCT CO/PBX Ringing Variation Selection 3-07 +BTT CO Ringing Pattern Selection for Telephone Mode...
  • Page 593: Drop Key

    Xen IPK Programming Manual Drop Key Menu Access System Data Name Memory Block Keyboard Shortcut Line Key Selection 2-05 Line Key Selection for Tenant Mode 2-06 +BTM Line Key Selection for Telephone Mode 4-12 Elapsed Call Timer Menu Access System Data Name...
  • Page 594 NEC Business Solutions Ltd December 2004 E & M Tie Lines (4-Wire) (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +ALM Tie Line Wink/Delay Signal Detect Timeout Selection 3-25 +ALT Tie Line Dial Tone Selection 3-27 +ALT Tie Line Reorder Tone Selection...
  • Page 595: Flexible Line Assignment

    Xen IPK Programming Manual External Zone Paging (Meet-Me) Menu Access System Data Name Memory Block Keyboard Shortcut Access Code (1-, 2-, or 3-Digit) Assignment 1-1-46/47/48 +BTD Attendant Add-On Console Key Assignment 1-6-05 Line Key Selection 2-05 Line Key Selection for Tenant Mode...
  • Page 596: Flexible Ringing Assignment

    NEC Business Solutions Ltd December 2004 Flexible Ringing Assignment Menu Access System Data Name Memory Block Keyboard Shortcut +BTS Distinctive Ring by Telephone or CO Selection 1-1-28 +BCT CO/PBX Ringing Variation Selection 3-07 +BTT CO/PBX Ring Assignment (Day Mode) 4-01...
  • Page 597 Xen IPK Programming Manual Flexible Timeouts (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut Internal Paging Timeout Selection 1-2-00 Automatic Callback Release Timer Selection 1-2-02 Call Forward No Answer Timer Selection 1-2-22 System Call Park Recall Time Selection...
  • Page 598: Full Handsfree Operation

    NEC Business Solutions Ltd December 2004 Flexible Timeouts (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +ALM Tie Line Prepause Time Selection 3-16 +ALM Tie Line Answer Detect Time Selection 3-17 +ALM Tie Line Release Detect Time Selection...
  • Page 599: Headset Connection

    Xen IPK Programming Manual Headset Connection Menu Access System Data Name Memory Block Keyboard Shortcut Line Key Selection 2-05 Line Key Selection for Tenant Mode 2-06 +BTM Line Key Selection for Telephone Mode 4-12 Hold with Recall (Exclusive and Non-Exclusive)
  • Page 600 NEC Business Solutions Ltd December 2004 Internal Voice/Tone Signalling Menu Access System Data Name Memory Block Keyboard Shortcut Intercom Call Voice/Tone Signal Selection 1-2-01 +BTD DSS Call Voice/Tone Signal Selection 1-6-03 Internal Zone Paging (Meet-Me) Menu Access System Data Name...
  • Page 601 Xen IPK Programming Manual ISDN - Caller ID Menu Access System Data Name Memory Block Keyboard Shortcut Caller ID Display Assignment for System Mode 1-1-78 1-8-08 +BTS Class of Service (Station) Feature Selection 2 (Pg. LK3/LK4) Caller ID Display Assignment for CO/PBX Line...
  • Page 602: Message Waiting

    NEC Business Solutions Ltd December 2004 Live Monitoring Menu Access System Data Name Memory Block Keyboard Shortcut 1-8-08 +BTS Class of Service Feature Selection 2 (Page 5 LK6) +BTM Line Key Selection for Telephone Mode 4-12 Message Waiting Menu Access...
  • Page 603: Music On Hold

    Xen IPK Programming Manual Music on Hold Menu Access System Data Name Memory Block Keyboard Shortcut +BCS Music on Hold Pattern Selection 1-8-09 CO External Source Selection 3-11 CO Hold Melody Selection 3-12 Night Call Pickup Menu Access System Data Name...
  • Page 604 NEC Business Solutions Ltd December 2004 Night Transfer (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +BTT Telephone to Tenant Assignment 4-09 +BTT Station to Class of Service Feature Assignment 4-17 +BTM Extension Line Key Ring Assignment (Day Mode)
  • Page 605: Preset Dialling

    Xen IPK Programming Manual Preset Dialling Menu Access System Data Name Memory Block Keyboard Shortcut 1-8-08 +BTS Class of service (Station) Feature Selection 2 Page 5 Line Key 5 Caller ID/Preset Dial Outgoing CO Selection 4-44 Prime Line Assignment Menu Access...
  • Page 606: Ringing Line Preference

    NEC Business Solutions Ltd December 2004 Restriction (Outgoing) Menu Access System Data Name Memory Block Keyboard Shortcut +BTT Trunk Outgoing Restriction 4-19 Ringing Line Preference Menu Access System Data Name Memory Block Keyboard Shortcut +BTS Class of Service (Station) Feature Selection 2...
  • Page 607: Secondary Incoming Extension

    Xen IPK Programming Manual Secondary Incoming Extension Menu Access System Data Name Memory Block Keyboard Shortcut Line Key Selection 2-05 Line Key Selection for Tenant Mode 2-06 +BTM Line Key Selection for Telephone Mode 4-12 +BTM Extension Line Key Ring Assignment (Day Mode)
  • Page 608: Slt Adapter

    NEC Business Solutions Ltd December 2004 Single Line Telephone Access (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +BCT DIT Assignment 3-42 +BCT ANA Assignment 3-43 +BTT CO/PBX Ring Assignment (Day Mode) 4-01 +BTT CO/PBX Ring Assignment (Night Mode)
  • Page 609: Speed Dial System

    Xen IPK Programming Manual Speed Dial Station Menu Access System Data Name Memory Block Keyboard Shortcut Speed Dial Buffer Allocation 1-1-35 Speed Dial System Menu Access System Data Name Memory Block Keyboard Shortcut System Speed Dial Restriction by Tenant 1-1-18...
  • Page 610: Station Outgoing Lockout

    NEC Business Solutions Ltd December 2004 Station Outgoing Lockout Menu Access System Data Name Memory Block Keyboard Shortcut Access Code (1-, 2-, or 3-Digit) Assignment 1-1-46/47/48 Code Restriction Class Assignment when Lockout is Set 1-1-70 +BTS Class of Service (Station) Feature Selection 2...
  • Page 611: Stored Hookflash

    Xen IPK Programming Manual Stored Hookflash Menu Access System Data Name Memory Block Keyboard Shortcut +BCM Hookflash Time Selection 1-1-02 Synchronous Ringing Menu Access System Data Name Memory Block Keyboard Shortcut +BCS Synchronous Ringing Selection 1-1-59 Tandem Switching of 4-Wire E&M Tie Lines...
  • Page 612: Tone Override

    NEC Business Solutions Ltd December 2004 Tone Override Menu Access System Data Name Memory Block Keyboard Shortcut +BTS Class of Service (Station) Feature Selection 2 1-8-08 +BTT Station to Class of Service Feature Assignment 4-17 Trunk Queuing Menu Access System Data Name...
  • Page 613 Xen IPK Programming Manual Uniform Call Distribution (UCD) (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut +BCT ANA Assignment 3-43 +BCT Polarity Reverse Selection 3-90 +BTM Line Key Selection for Telephone Mode 4-12 Card Interface Slot Assignment MIF (UCD) Assignment...
  • Page 614: Menu Access

    NEC Business Solutions Ltd December 2004 Example: The diagram provides an example of Memory Blocks that would be programmed for a Closed Numbering Plan. Abbreviations used in the diagram AC = Access Codes BLK = Block MB = Memory Block...
  • Page 615 Xen IPK Programming Manual Uniform Numbering Network – Open Numbering Plan (Continued) Menu Access System Data Name Memory Block Keyboard Shortcut Station Number Assignment 4-10 +ALN Tie Line Networking Tandem Connection Assignment 5-01 Example: This diagram provides an example of Memory Blocks that would be programmed for a Closed Numbering Plan.
  • Page 616: Universal Slots

    NEC Business Solutions Ltd December 2004 Universal Slots Menu Access System Data Name Memory Block Keyboard Shortcut Card Interface Slot Assignment MIF (ACD) Assignment 7-3-00 MIF (LCR) Assignment 7-3-01 MIF (SMDR) Assignment 7-3-02 MIF (UCD) Assignment 7-3-03 Unsupervised Conference Menu Access...
  • Page 617: Voice Prompt

    Xen IPK Programming Manual Voice Over Split Menu Access System Data Name Memory Block Keyboard Shortcut 1-2-24 Intercom Feature Access Code Assignment (Item 006) 1-8-08 +BTS Class of Service (Station) Feature Selection 2 (Pg. 1, LK8 and Pg. 3, LK3)
  • Page 618 NEC Business Solutions Ltd December 2004 THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 598 – Chapter 2 Section 2, Programming Guide Tables...
  • Page 619: General Information

    PC Programming Chapter 3 SECTION 1 This chapter provides detailed information for programming using the Xen Maintenance Access Terminal (MAT) software. GENERAL INFORMATION PC requirements: Microsoft Windows 95 operating system Available serial communication port on PC MNP Class 4 or V.42 bis modem (if remote programming is required) KTS hardware requirements: MIFM-U( ) KTU IMPORTANT...
  • Page 620: Software Installation

    Follow the instructions on the PC installation program. To start the MAT program: Click the Win 95 start button. Select PROGRAMS, NEC Xen MAT. Click Xen Maintenance Access Terminal (MAT). Enter the password. The default password is PASSWORD in uppercase letters.
  • Page 621: Figure 3-1: Accessing Wizard

    Xen IPK Programming Manual Select from the toolbar. Accessing Wizard Figure 3-1: When Wizard is displayed, the technician can select any feature from the list or can begin entering letters of the feature name. As the name is being entered, Quick Search finds the matching letters and highlights the match.
  • Page 622: Figure 3-3: Sample Wizard

    NEC Business Solutions Ltd December 2004 When a feature is selected, all system related data items for that feature are presented in sequence. Enter the required values in the current tab and click next to advance to the next tab. Click back to go to previous tab. In Figure 3-3: Sample Wizard, the Account Code Entry feature is selected.
  • Page 623: Programming Screens

    When the MAT software program is launched, the Main Menu screen is displayed first. This screen allows the user to access the options used to SCREENS program the Xen system. Figure 3-4: Xen IPK Maintenance Access Terminal Software Screen Samples shows the menu and describes the layout. Pulldown Menu Pulldown menus are available for each function involved in programming the Xen system.
  • Page 624: Main Menu

    Keyboard box surrounding the tab available for this option. displayed. Shortcut. name. Xen IPK Maintenance Access Terminal Software Screen Samples Figure 3-4: DRAFT 3 604 – Chapter 3 Section 5, Programming Screens...
  • Page 625: Toolbar

    When the icon appears shadowed, the tool is not available. When the icon is dark, the tool is available. Refer to Figure 3-4: Xen IPK Maintenance Access Terminal Software Screen Samples for an example.
  • Page 626 NEC Business Solutions Ltd December 2004 Accesses Quick Search. Quick Search provides a detailed list of system data items. Returns to the previous tab group. Advances to the next tab group. Displays the help contents for the Xen MAT software program.
  • Page 627: Xen Ipk Pulldown Menus

    Saves a configuration file using a new name. This option is only available when a configuration file is open. Close Closes the current configuration file. This option is only available when a configuration file is open. DRAFT 3 Section 7, Xen IPK Pulldown Menus Chapter 3 – 607...
  • Page 628: Change Password

    When Designation Labels is selected, MAT automatically opens the DESI for Windows label printing application. The current telephone information is automatically exported to DESI. Labels can then be configured and printed for the telephones. This requires the NEC LASER Labels for printing on InkJet or Laser printers. Note: For the Designation Labels option to be enabled, the DESI for Windows application must be installed on your computer.
  • Page 629: Figure 3-6: Edit Menu

    The user can scroll through the list and click on the desired Memory Block. System data can then be modified as necessary. DRAFT 3 Section 7, Xen IPK Pulldown Menus Chapter 3 – 609...
  • Page 630: Figure 3-7: Basic Menu

    This option allows the technician to assign the terminals to the system. Several selections are available with this option. System Wide Station Base Multiline Single Line DSS/BLF Doorphones DRAFT 3 610 – Chapter 3 Section 7, Xen IPK Pulldown Menus...
  • Page 631 This option allows Call Arrival block assignments to be programmed. Forced Account Codes This option allows the technician to program the account code length and to assign account codes. DRAFT 3 Section 7, Xen IPK Pulldown Menus Chapter 3 – 611...
  • Page 632: Figure 3-8: Application Menu

    TLI/DID This option allows data related to Tie Lines and Direct Inward Dialling to be programmed. Three selections are available with this option: Trunk Base Networking Timers DRAFT 3 612 – Chapter 3 Section 7, Xen IPK Pulldown Menus...
  • Page 633 BRT DTMF duration. This option allows the programming of data related to PHS (Personal Handy-phone System) such Telephone Assignment and PS Out of Area Tone Selection. DRAFT 3 Section 7, Xen IPK Pulldown Menus Chapter 3 – 613...
  • Page 634: Speed Dialling

    The Users pulldown menu allows access to system data items related to speed dialling. User Menu Figure 3-9: Speed Dialling This option allows the technician to program Speed Dial memories for each Multiline Terminal in the Xen system. DRAFT 3 614 – Chapter 3 Section 7, Xen IPK Pulldown Menus...
  • Page 635: Figure 3-10: Communications Menu

    KTS located at a remote location. In either case, after a successful connection is established with the KTS, you are ready to upload and download data to and from the KTS. DRAFT 3 Section 7, Xen IPK Pulldown Menus Chapter 3 – 615...
  • Page 636 NEC Business Solutions Ltd December 2004 Disconnect This option allows the technician to disconnect from the Xen IPK system. Upload This option allows the technician to upload programming changes and configurations to the KTS. Download This option allows the technician to download the current Xen configuration.
  • Page 637: Figure 3-11: Help Menu

    When the cursor is positioned over a data field, the memory block number is displayed above the cursor. About This option provides information about the Maintenance Access Terminal software (MAT). DRAFT 3 Section 7, Xen IPK Pulldown Menus Chapter 3 – 617...
  • Page 638 NEC Business Solutions Ltd December 2004 THIS PAGE INTENTIONALLY LEFT BLANK DRAFT 3 618 – Chapter 3 Section 7, Xen IPK Pulldown Menus...

Table of Contents