Page 3
GENERAL PRECAUTIONS REGARDING THE SERVICE FOR e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283 SERIES The installation and service should be done by a qualified service technician. 1) Transportation/Installation When transporting/installing the equipment, employ two persons and be sure to hold the posi- tions as shown in the figure.
Page 4
If these parts are short-circuited and their functions become ineffective, they may result in fatal accidents such as burnout. Do not allow a short-circuit or do not use the parts not recommended by Toshiba TEC Corporation. 4) Cautionary Labels During servicing, be sure to check the rating plate and cautionary labels such as “Unplug the power cable during service”, “CAUTION.
Page 5
5) Disposal of the Equipment, Supplies, Packing Materials, Used Batteries and IC-RAMs Regarding the recovery and disposal of the equipment, supplies, packing materials, used batter- ies and IC-RAMs including lithium batteries, follow the relevant local regulations or rules. Caution: Dispose of used batteries and IC-RAMs including lithium batteries according to this manual. Attention: Se débarrasser de batteries et IC-RAMs usés y compris les batteries en lithium selon ce manuel.
Page 9
6.2.2 Writing the data to the download jig (PWA-DWNLD-350-JIG) ....... 6-48 6.2.3 K-PWA-DLM-320....................6-50 6.3 Firmware Updating with FSMS (Field Service Manager) (e-STUDIO200L/230/230L/280) 6-60 6.4 Firmware Updating with USB Storage Device (e-STUDIO200L/230/230L/280)....6-72 6.5 Firmware Updating with USB Storage Device (e-STUDIO202L/203L/232/233/282/283).. 6-86 6.6 Appendix..........................
SPECIFICATIONS / ACCESSORIES / OPTIONS / SUPPLIES Specifications Values in { } are for e-STUDIO200L/202L/203L and values in [ ] are for e- STUDIO280/280S/282/ 282S/283/283S in case that the specification is different among e-STUDIO200L/202L/203L, e-STUDIO230/230L/232/232S/233 and e-STUDIO280/280S/282/282S/283/283S. Copy process Indirect electrophotographic process (dry) Type...
(Press to display the screen on the control panel at power-ON.) • Test mode (03): Refer to P. 2-25 "2.2.1 Input check (Test mode 03) (e-STUDIO200L/230/230L/ 280)"/ P. 2-32 "2.2.2 Input check (Test mode 03) (e-STUDIO202L/203L/232/233/282/283)" and P. 2-40 "2.2.3 Output check (test mode 03)".
Page 122
The digit after the hyphen in “Code” of the following table is a sub code. • e-STUDIO200L/230/230L/280:In “RAM”, the NVRAM of the board in which the data of each code is stored is indicated. “M” stands for the LGC board, “SYS” and “UTY” stands for the SYS board and “NIC”...
Page 308
Display in the setting mode (08) Information of pixel count can be also checked in the setting mode (08). For details, see P. 2-84 "2.2.7 Setting mode (08) (e-STUDIO200L/230/230L/280)"/ P. 2-153 "2.2.8 Setting mode (08) (e-STUDIO202L/203L/232/233/282/283)". Print count, pixel count...
Also, make sure to adjust the tray volume when the initialization of EEPROM and automatic sensor adjustment have been performed. Refer to P.2-44 "2.2.5 Adjustment mode (05) (e-STUDIO200L/230/230L/280)" for the details. Errors such as paper jamming may occur if the EEPROM is not initialized and the sensors are not adjusted after the above mentioned parts were replaced.
Page 434
74,000 sheets e-STUDIO280/282/283: every 90,000 sheets • Values under “Replacement” indicate the replacement cycle for the e-STUDIO200L/ e-STUDIO230/e-STUDIO230L/e-STUDIO280 or e-STUDIO202L(203L)/e-STUDIO232(233)/ e-STUDIO282(283). • The replacement cycle of the parts in the feeding section equals to the number of sheets fed from each paper source.
Install DIMM (main memory) to the new SYS board (from the old SYS board). Install NVRAM to the new SYS board (from the old SYS board). Install NIC board to the new SYS board (from the old SYS board). (e-STUDIO200L/230/230L/ 280) Update the version of system ROMs (System Firmware, OS data, UI data) (The ROMs had been used for the old SYS board).
Updating with the download jig P.6-3 "6.1 Firmware Updating with Download Jig (e-STUDIO200L/230/230L/280)" • Updating with PC connected P.6-60 "6.3 Firmware Updating with FSMS (Field Service Manager) (e-STUDIO200L/230/230L/ 280)" • Updating with the USB Storage Device P.6-72 "6.4 Firmware Updating with USB Storage Device (e-STUDIO200L/230/230L/280)"...