Basic 4.3" video hands-free indoor station
Hide thumbs Also See for M22344-W:

Advertisement

VER:1.0 │
│ 31/12/2015
ABB-Welcome
Pos : 2 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Titelbl att - 83220-AP- xxx - ABB @ 19\mod_1323249806476_15.doc x @ 111084 @ @ 1
M22344-W
Basic 4.3" Video hands-free
indoor station
=== Ende der Liste fü r T extmar ke Cover ===

Advertisement

Table of Contents
loading

Summary of Contents for ABB M22344-W

  • Page 1 VER:1.0 │ │ 31/12/2015 ABB-Welcome Pos : 2 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Titelbl att - 83220-AP- xxx - ABB @ 19\mod_1323249806476_15.doc x @ 111084 @ @ 1 M22344-W Basic 4.3" Video hands-free indoor station...
  • Page 2: Table Of Contents

    Pos : 4 /Busch-J aeger (Neus truktur)/M odul-Str uktur/Online-Dokumentation/Inhal ts verz eic hnis (--> Fü r alle D okumente <--)/Inhalts verz eichnis @ 19\mod_1320649044386_15.doc x @ 109653 @ @ 1 Safety ......................3 Intended use ....................3 Environment ....................3 ABB devices ................. 3 Operations ..................... 5 Standard operations ..............5 4.1.1 Control elements ................
  • Page 3: Safety

    ABB devices Pos : 13 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/U mwel t (--> Fü r alle D okumente <--)/Hinweis e/Hi nweis - U mwelt - ABB El ektr ogeräte @ 19\mod_1323162745839_15.doc x @ 110867 @ @ 1 All packaging materials and devices from ABB bear the markings and test seals for proper disposal.
  • Page 4 ABB-Welcome (EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS) (EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)
  • Page 5: Operations

    ABB-Welcome Pos : 18 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Bedi enung @ 18\mod_1302613924165_15.doc x @ 103365 @ 1 @ 1 Operations Pos : 19 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Nor maler Betrieb @ 18\mod_1302768820965_15.doc x @ 103540 @ 2 @ 1 Standard operations Pos : 20 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Bedi enel emente @ 20\mod_1323260220559_15.doc x @ 111647 @ 3 @ 1...
  • Page 6 ABB-Welcome Functions 4.3" Color display Comunication button 2A When a call is coming, press this button to activate the communication within 30 seconds and press it again to end the call. 2B In standby mode, press this button to enter the communication menu.
  • Page 7: Control Actions

    ABB-Welcome Pos : 26 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Bedi enaktionen @ 20\mod_1323262294281_15.doc x @ 111911 @ 2 @ 1 Control actions Pos : 27 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Sprec h- und Videover bindung @ 20\mod_1323262368700_15.doc x @ 111927 @ 3 @ 1 4.2.1...
  • Page 8: Display & Volume Settings During Calling

    ABB-Welcome Pos : 30 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Tuer oeffnen @ 20\mod_1323263277453_15.doc x @ 111935 @ 3 @ 1 4.2.2 Display & volume settings during calling Pos : 31 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/T uer oeffnen - 83220- AP- xxx @ 20\mod_1323267958479_15.doc x @ 112109 @ @ 1...
  • Page 9: Communication Menu

    ABB-Welcome Pos : 33 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Stumm s chalten @ 20\mod_1323263607142_15.doc x @ 111951 @ 3 @ 1 Pos : 66 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ü r all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1 4.2.3...
  • Page 10 ABB-Welcome 4.2.3.2 Switch actuator SWITCH ACTUATOR Actuator 1 (001) Fig. 4: Switch actuator Set the actuator list in the “system settings-switch actuator“ menu first. After chosing a list, press button √ to enable the lock or light which is connected with the...
  • Page 11: Settings

    ABB-Welcome Settings 4.3.1 Overview Press button to enter the system settings menu. The following functions are available: Functions Switch actuator -Set the actuator list in this menu Program button -Set functions for programmable buttons Ringtone -Set the ringtone for outdoor bells, indoor bell or others...
  • Page 12: Switch Actuator Settings

    ABB-Welcome 4.3.2 Switch actuator settings SWITCH ACTUATOR Actuator 1 (001) Add New Add a new list SWITCH ACTUATOR Target Address Rename light Save Cancel Fig. 5: Switch actuator settings Functions Existing switch actuator list: Press button √ to modify the settings.
  • Page 13: Program Button Settings

    ABB-Welcome 4.3.3 Program button settings PROGRAM BUTTON Button 1 Release 2nd-Lock Fig. 6: Program button settings Functions Set functions for the program button, e.g. releasing 2nd-lock, calling guard unit, enabling the switch actuator. *Only the switch actuator list can be assigned...
  • Page 14: Ringtone Settings

    ABB-Welcome 4.3.4 Ringtone settings RING TONE Ring Tone 1 Default Outdoor Ring Tone 2 Other Outdoors Ring Tone 3 Doorbell Ring Tone 4 Others Fig. 7: Ringtone Functions Select the bell sound for the default outdoor station. Select the bell sound for other outdoor stations.
  • Page 15: Volume Settings

    ABB-Welcome 4.3.5 Volume settings VOLUME Volume 3 Ringtone Volume √ Touchbutton Tone √ Repeated Tone Fig. 8: Volume settings Functions Set the volume of bell sound. Enable/disable the feedback tone which sounds when the touch button is pressed. The ringtone can be set fixed or cycled.
  • Page 16: Date And Time Settings

    ABB-Welcome 4.3.6 Date and time settings DATE AND TIME 2013 Date(YYYY-MM-DD) : Time Summer Time √ Fig. 9: Date and time settings Functions Set the date. Set the time. Enable/disable the summer time function.
  • Page 17: Other Settings

    ABB-Welcome 4.3.7 Other settings OTHER SETTINGS Auto Full Screen √ √ Auto-snapshots √ Missed Call Fig. 10: Other settings Functions Enable/disable the auto full screen function. Enable/disable the auto-snapshot function. Enable/disable the missed call function( flashes when there is a missed...
  • Page 18: History Review

    ABB-Welcome 4.3.8 History review HISTORY 1/63 2013-03-21 Outdoor - 1 ● 16:45 ● 2013-03-21 Outdoor - 1 16:45 ● 2013-03-21 Outdoor - 1 14:24 Outdoor -1 Fig. 11: History review Functions Up to 100 events can be recorded in the history menu.
  • Page 19 ABB-Welcome Press this button to view details of this event. Two pictures are always made when a visitor rings the bell. Press this button to delete a record item...
  • Page 20: Language Settings

    ABB-Welcome 4.3.9 Language settings LANGUAGE English Fig. 12: Language settings...
  • Page 21: Information

    ABB-Welcome 4.3.10 Information INFORMATION Flash Version: V1.02_151210_US MCU Version: V1.02_151210_US M/S: Master Indoor St. Add.: Default Outdoor: Fig. 13: Information of the indoor station (scanning the QR code to get the detailed instruction of the indoor station)
  • Page 22: Reseting Factory Default

    ABB-Welcome 4.3.11 Reseting factory default RESET FACTORY DEFAULT Are you sure to reset? Reset All Settings √ Clear All Data × Cancel Fig. 14: Reseting factory default Functions Reset all settings: Reset the device and restore all default configurations. The operation does not delete the programmed data and history, such as switch actuator lists.
  • Page 23: Cleaning

    ABB-Welcome Pos : 67 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Rei nigung @ 19\mod_1310733980533_15.doc x @ 107853 @ 2 @ 1 Cleaning Pos : 68 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Rei nigung/Rei nigung Touc hscreenmonitor @ 19\mod_1310734108978_15.doc x @ 107862 @ @ 1 Caution Risk of damage to the screen surface.
  • Page 24: Adjusting The Device

    ABB-Welcome Pos : 70 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Geraeteei nstellungen @ 18\mod_1302768847744_15.doc x @ 103548 @ 2 @ 1 Adjusting the device Pos : 71 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Absc hlus s widerstand @ 19\mod_1321958079906_15.doc x @ 110083 @ 3 @ 1 Pos : 72 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Absc hl uss widerstand setzen 83220-AP- xxx @ 19\mod_1310723392369_15.doc x @ 107841 @ @ 1...
  • Page 25: Technical Data

    ABB-Welcome Pos : 76 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Tec hnisc he D aten @ 18\mod_1302615863001_15.doc x @ 103416 @ 1 @ 1 Technical data Pos : 77 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/T ec hnische D aten - 83220-AP- xxx @ 18\mod_1303212854559_15.doc x @ 103705 @ @ 1...
  • Page 26: Mounting / Installation

    ABB-Welcome Pos : 79 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Übersc hriften (--> Fü r alle D okumente <--)/1. Ebene/M - O/Montage / Installation @ 18\mod_1302613966111_15.doc x @ 103373 @ 1 @ 1 Mounting / Installation Pos : 80 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Fü r alle Dokumente <--)/Warnhinweis e/Sic herheit - Ni eders pannungs- und 230 V-Leitungen @ 18 \mod_1302617821491_15.doc x @ 103465 @ @ 1...
  • Page 27: General Installation Instructions

    ABB-Welcome General installation instructions • Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station, system device). • Do not install the system controller directly next to the bell transformer and other power supplies (to avoid interference).
  • Page 28: Mounting

    ABB-Welcome Pos : 84 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Übersc hriften (--> Fü r alle D okumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.doc x @ 103424 @ 2 @ 1 Mounting Recommended installation height Dismantling Open the housing of the panel by pulling the clamp at the bottom of the device.
  • Page 29 ABB-Welcome Installation dimension The bottom of the device has screw holes for fastening on the wall according to the above dimension instructions. In addition, the bottom of the device can be fixed to the existing flush -mounted box. The dimension of the compatible flush-mounted box is shown in graphics above.
  • Page 30 ABB-Welcome Settings Set addresses of the preferred outdoor stations and the address of the indoor station on Adjusting the device the jumper (see chapter " "). Three types of installation: Surface-mounted Mounted on the wall Fix the bottom of the device to the wall.
  • Page 31 ABB-Welcome Desktop-mounted Mounted with desktop bracket Fix the bottom of the device to the desktop bracket. Latch the upper part of the device onto its bottom part : place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp.
  • Page 32 We reserve the right to at all times make technical changes as well as changes in the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.