Entering Programming Mode
You may find it convenient to adjust the volume setting before entering the Programming Mode. This
will allow you to clearly hear feedback announcements or system beeps.
1. Power up the LYNX Touch control, when the Home Screen appears, select "More".
2. Select "Tools". The system displays a virtual keypad.
3. Enter: Installer Code (4 + 1 + 1 + 2).
4. The System Programming Screen is displayed. Select "Program". The Armed and Ready LEDs will flash and
the following options will be displayed:
Installer Code
Date Time
Zones
Keys
Use the down
arrow to scroll to the next page of options.
Sounder
Default Config.
Reset Master Code
* This field may not be applicable to the system being installed.
5. Select an option to advance to that Programming screen.
Note:
If a different Installer Code has been programmed, enter: the New Installer Code.
Programming the Data Fields
1. Select each desired programming option, and then select the required entry. The system beeps each time a
selection is made.
2. The system will toggle or scroll through the options or display a new screen as required for the specific
option.
3. To delete or change an entry, simply select the desired option, and then select the required entry.
Loading a Default Set:
1. Enter the Installer Programming Mode and advance to second page of the System Programming.
2. Select 'Default Config' and select the appropriate Default Table Configuration from the following options or
Select Default Downloader to reset all subscriber account numbers and CSID in preparation for an initial
download:
Default Config 1
Default Config 2
Default Config 3
Default Config 4
Default Downloader
Note: Refer to the Programming Default Tables section of this manual to view the default values.
Exiting Programming Mode:
1. Select the " " key to exit the current screen. The system returns to the previous screen.
2. Select the " " key as required until system displays a Confirmation screen.
3. Select "Yes" to allow the installer to re-enter Programming mode or "No" to prevent re-entry. If "No" is
selected, you can still re-enter Program Mode by powering down the unit (remove AC and battery power) and
entering Program Mode within 30 seconds of powering up.
4. Select the " " key again to return to the Home Screen.
System Type