Water Pump Control [Disabled]
[Disabled]
Disable the Water Pump control feature.
[DC mode]
Enable the Water Pump control in DC mode for 3-pin chassis fan.
[PWM mode]
Enable the Water Pump control in PWM mode for 4-pin chassis fan.
The following items appear only when you set the Water Pump Control to [DC mode] or
[PWM mode].
Water Pump Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the Water Pump temperature. The
values range from 45 to 75.
Water Pump Max. Duty Cycle (%) [100]
Use the <+> or <-> keys to adjust the maximum Extension Fan 1-4 duty cycle. The
values range from 60% to 100%. When the CPU temperature reaches the upper limit,
the Water Pump will operate at the maximum duty cycle.
Water Pump Middle Temperature [25]
Use the <+> or <-> keys to adjust the middle limit of the Water Pump temperature. The
values range from 40 to 75.
Water Pump Middle. Duty Cycle (%) [20]
Use the <+> or <-> keys to adjust the maximum Water Pump duty cycle. The values
range from 60% to 100%. When the CPU temperature reaches the upper limit, the
Water Pump will operate at the maximum duty cycle.
Water Pump Lower Temperature [20]
Use the <+> or <-> keys to adjust the lower limit of the Water Pump temperature. The
values range from 0 to 75. The Water Pump will operate at the minimum duty cycle
when the temperature is lower than the limit.
Water Pump Min. Duty Cycle(%) [20]
Use the <+> or <-> keys to adjust the minimum Water Pump duty cycle. The values
range from 60% to 100%. When the CPU temperature is under the limit, the Water
Pump will operate at the minimum duty cycle.
2.7.6
Anti Surge Support [On]
This item allows you to enable or disable the Anti Surge function.
Configuration options: [On] [Off]
ASUS B150 PRO GAMING
2-35