Sign In
Upload
Manuals
Brands
IBM Manuals
Server
Power System 8001-12C
User Manuals: IBM Power System 8001-12C Server
Manuals and User Guides for IBM Power System 8001-12C Server. We have
4
IBM Power System 8001-12C Server manuals available for free PDF download: Installing, Manual, Service Manual, Quick Install Manual
IBM Power System 8001-12C Installing (132 pages)
Brand:
IBM
| Category:
Server
| Size: 28.21 MB
Table of Contents
Table of Contents
5
Safety Notices
7
Installing and Configuring POWER8 Processor-Based Systems and System Features
17
Installing the IBM Power System S821LC (8001-12C) System
17
Prerequisites for Installing the Rack-Mounted 8001-22C System
17
Completing Inventory for Your System
17
Determining and Marking the Location in the Rack for the 8001-12C System
18
Attaching the Rails to the System Chassis and to the Rack
19
Installing the System into the Rack and Connecting and Routing Power Cables
21
Completing Server Setup
24
Installing Drives in the 8001-12C System
24
Drive Installation Details for the 8001-12C System
24
Installing a Front Drive in the 8001-12C System
26
Installing a Drive on Module in the 8001-12C System
30
Installing a Graphics Processing Unit in the 8001-12C System
32
Installing Memory in the 8001-12C System
35
Placement Rules for Memory in the 8001-12C or 8001-22C System
35
Installing Memory in the 8001-12C System
36
Installing a Pcie Adapter in the 8001-12C System
39
Pcie Adapter Placement Rules and Slot Priorities for the 8001-12C or 8005-12N System
39
Pcie Adapter Information by Feature Type for the 8001-12C or 8005-12N
47
Gb/S Eight-Port SAS Internal HBA Adapter (Adapter FRU Number: AOC-S3008L-L8E-P)
48
Pcie3 X4 Intel X550 10Gbase-T Converged Network Adapter with Dual RJ45 Ports (FC EKA0)
50
Network Adapter with Dual RJ45 Ports (FC EKA0)
50
Cavium (Qlogic) BCM57840 4-Port SFP+ 10 Gb Ethernet Adapter Pcie3.0 X8 LP (FC EKA1)
51
Intel 82599ES Ethernet Converged Network Adapter X520-DA2 Dual-Port 10G/1G SFP+ Pcie2.0 X8 LP (FC EKA2)
53
Intel 82575EB Dual-Port Gigabit Ethernet Controller Pcie X4.0 LP (FC EKA3)
55
Broadcom (LSI) Megaraid 9361-8I SAS3 Controller with 8 Internal Ports (1 GB Cache) Pcie3.0 X8 LP with Cables (FC EKAA and EKEA)
57
SMC AOC-K-S3008L-L8I 12 Gbps SAS3/RAID 0,1 and 10 Pcie3.0 X8 LP with Cables (FC EKAB and EKEB)
59
Broadcom (LSI) 9300-8E SAS3 HBA Pcie3.0 X8 LP Adapter (FC EKAD and EKED)
61
Pcie3 X8 Dual-Port Internal Nvme Host Bus Adapter (FC EKAE and EKEE)
63
Emulex LPE16002B-M6-O Dual-Port 16 Gb Fibre Channel Card Pcie3.0 X8 LP (FC EKAF)
65
SMC Quad-Port Nvme Host Bus Adapter (PEX9733) Pcie3.0 X8 LP with Cables (FC EKAG and EKEG)
67
Broadcom (LSI) Megaraid 9361-8I SAS3
69
Pcie3.0 X8 with Cables (FC EKAH and EKEH)
69
NVIDIA Tesla K80 24 GB GPU Accelerator (FC EKAJ)
71
Mellanox MCX456A-ECAT Connectx-4 VPI EDR IB 100 Gb/S and 100 Gbe Dual-Port QSFP28 Pcie3.0 X16 LP (FC EKAL)
73
Mellanox MCX415A-CCAT Connectx-4 en 100 Gbe Single-Port QSFP28 Pcie3.0 X16 LP (FC EKAM)
76
Qlogic QLE2562 Dual-Port 8 Gb Fibre Channel Adapter Pcie X8 LP (FC EKAP)
77
Qlogic QLE2692OP Dual-Port 16 Gb Fibre Channel Adapter Pcie3 X8 LP (FC EKAQ)
79
Alpha-Data CAPI Adapter: ADM-Pcie KU3 (FC EKAT)
81
Mellanox MCX4121A-ACAT Connectx-4 Lx en 25Gbe Dual-Port SFP28 Pcie3.0 X8 LP (FC EKAU)
84
NVIDIA Tesla P100 16GB Pcie3.0 X16 Dual-Slot FHFL with Cables (FC EKAZ)
85
Intel XL710 Ethernet Converged Network Adapter Quad-Port 10G/1G SFP+ Pcie3.0 X8 LP (FC EKFH)
87
Pcie3 1.6 TB Nvme Flash Adapter (FC EKN2)
89
Installing a Pcie Adapter in the 8001-12C System
91
Common Procedures for Servicing or Installing Features in the 8001-12C or 8005-12N
96
Before You Begin
96
Identifying the System that Contains the Part to Replace
99
Leds on the 8001-12C or 8005-12N System
99
Identifying the 8001-12C, 8001-22C, 8005-12N, or 8005-22N that Needs Servicing
101
Preparing the 8001-12C or 8005-12N System to Remove and Replace Internal Parts
101
Preparing the 8001-12C or 8005-12N System for Operation after You Remove and Replace Internal Parts
103
Starting and Stopping the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
104
Starting the 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
104
Stopping the 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
106
Drive Commands for 8001-12C, 8001-22C, 8005-12N, or 8005-22N
106
Mvcli Commands
106
Storcli Commands
107
Sas3Ircu Commands
108
Nvme Commands
108
Sensor Readings GUI Display
109
Removing and Replacing a Power Supply in the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
109
Removing a Power Supply from the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
109
Replacing a Power Supply in the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
111
Removing and Replacing Covers on an 8001-12C or 8005-12N System
111
Removing the Service Access Cover from an 8001-12C or 8005-12N System
111
Installing the Service Access Cover on an 8001-12C or 8005-12N System
112
Service and Operating Positions for 8001-12C
113
Placing an 8001-12C System into the Service Position
113
Placing an 8001-12C System into the Operating Position
114
Power Cords
116
Disconnecting the Power Cords from an 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
116
Connecting the Power Cords to an 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
116
Notices
119
Accessibility Features for IBM Power Systems Servers
120
Privacy Policy Considerations
121
Trademarks
122
Electronic Emission Notices
122
Class a Notices
122
Class B Notices
126
Terms and Conditions
129
Advertisement
IBM Power System 8001-12C Manual (130 pages)
Problem analysis, system parts, and locations
Brand:
IBM
| Category:
Server
| Size: 15.91 MB
Table of Contents
Table of Contents
5
Safety Notices
7
Beginning Troubleshooting and Problem Analysis
17
Determining the Problem Analysis Procedure to Perform
17
Resolving a BMC Access Problem
18
Resolving a Power Problem
20
Resolving a System Firmware Boot Failure
21
Resolving a VGA Monitor Problem
22
Resolving an Operating System Boot Failure
23
Resolving a Sensor Indicator Problem
25
Resolving a Hardware Problem
26
Resolving a GPU, Pcie Adapter, or Device Problem
27
Resolving a RAID Adapter Problem
28
Resolving a Network Adapter Problem
29
Resolving a Graphics Processing Unit Problem
31
Resolving an Nvme Flash Adapter Problem
31
Resolving a Storage Device Problem
32
Identifying the Location of the Pcie Adapter by Using the Slot Number
34
Identifying the Location of the GPU by Using the Slot Number
35
Identifying the Location of the Nvme Flash Adapter
36
Identifying the Location of the Storage Device
36
User Guides for Gpus and Pcie Adapters
37
Identifying a Service Action
37
Identifying a Service Action by Using System Event Logs
37
Identifying Service Action Keywords in System Event Logs
42
Identifying a Service Action by Using Sensor and Event Information
43
Identifying a Service Action by Using Sensor and Event Information for the 8001-12C and 8005-12N
43
Identifying a Service Action by Using Sensor and Event Information for the 8001-22C and 8005-22N
59
Isolation Procedures
76
EPUB_PRC_FIND_DECONFIGURE_PART Isolation Procedure
77
EPUB_PRC_SP_CODE Isolation Procedure
77
EPUB_PRC_PHYP_CODE Isolation Procedure
77
EPUB_PRC_ALL_PROCS Isolation Procedure
78
EPUB_PRC_ALL_MEMCRDS Isolation Procedure
78
EPUB_PRC_LVL_SUPPORT Isolation Procedure
79
EPUB_PRC_MEMORY_PLUGGING_ERROR Isolation Procedure
79
EPUB_PRC_FSI_PATH Isolation Procedure
79
EPUB_PRC_PROC_AB_BUS Isolation Procedure
80
EPUB_PRC_PROC_XYZ_BUS Isolation Procedure
80
EPUB_PRC_EIBUS_ERROR Isolation Procedure
81
EPUB_PRC_POWER_ERROR Isolation Procedure
82
EPUB_PRC_MEMORY_UE Isolation Procedure
82
EPUB_PRC_HB_CODE Isolation Procedure
82
EPUB_PRC_TOD_CLOCK_ERR Isolation Procedure
83
EPUB_PRC_COOLING_SYSTEM_ERR Isolation Procedure
84
Verifying a Repair
85
Collecting Diagnostic Data
87
Contacting IBM Service and Support
87
Finding Parts and Locations
89
8001-12C or 8005-12N Locations
89
8001-12C or 8005-12N Parts
94
Finding Parts and Locations
103
8001-22C or 8005-22N Locations
103
8001-22C or 8005-22N Parts
109
Notices
117
Accessibility Features for IBM Power Systems Servers
118
Privacy Policy Considerations
119
Trademarks
120
Electronic Emission Notices
120
Class a Notices
120
Class B Notices
124
Terms and Conditions
127
IBM Power System 8001-12C Service Manual (118 pages)
Brand:
IBM
| Category:
Power Supply
| Size: 57.4 MB
Table of Contents
Table of Contents
5
Safety Notices
7
Removing and Replacing Parts
17
Removing and Replacing a Storage Drive in the 8001-12C or 8005-12N
18
Removing a Disk Drive from the 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
19
Replacing a Disk Drive in the 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
22
Removing a Drive on Module from the 8001-12C or 8005-12N System
26
Replacing a Drive on Module in the 8001-12C or 8005-12N System
27
Removing and Replacing the Disk Drive Backplane in the 8001-12C or 8005-12N
28
Removing the Disk Drive Backplane from the 8001-12C or 8005-12N
28
Replacing the Disk Drive Backplane in the 8001-12C or 8005-12N
31
Removing and Replacing Fans in the 8001-12C or 8005-12N
33
Removing a System Fan from the 8001-12C or 8005-12N
33
Replacing a System Fan in the 8001-12C or 8005-12N
37
Removing and Replacing a Graphics Processing Unit in the 8001-12C or 8005-12N
40
Removing the Graphics Processing Unit from the 8001-12C or 8005-12N System
40
Replacing the Graphics Processing Unit in the 8001-12C or 8005-12N System
42
Removing and Replacing Memory in the 8001-12C or 8005-12N
45
Removing and Replacing Pcie Adapters in the 8001-12C or 8005-12N
48
Removing a Pcie Adapter from the 8001-12C or 8005-12N System
48
Replacing a Pcie Adapter in the 8001-12C or 8005-12N System
52
Removing and Replacing the System Backplane in the 8001-12C or 8005-12N
56
Removing the System Backplane in the 8001-12C or 8005-12N
56
Replacing the System Backplane in the 8001-12C or 8005-12N
61
Removing and Replacing a System Processor Module in the 8001-12C or 8005-12N
70
Removing a System Processor Module from the 8001-12C or 8005-12N System
70
Replacing a System Processor Module for the 8001-12C or 8005-12N
74
Removing and Replacing the Time-Of-Day Battery in the 8001-12C or 8005-12N
79
Common Procedures for Servicing or Installing Features in the 8001-12C or 8005-12N
81
Before You Begin
81
Identifying the System that Contains the Part to Replace
84
Leds on the 8001-12C or 8005-12N System
84
Identifying the 8001-12C, 8001-22C, 8005-12N, or 8005-22N that Needs Servicing
85
Preparing the 8001-12C or 8005-12N System to Remove and Replace Internal Parts
86
Preparing the 8001-12C or 8005-12N System for Operation after You Remove and Replace Internal Parts
88
Starting and Stopping the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
89
Starting the 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
89
Stopping the 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
90
Drive Commands for 8001-12C, 8001-22C, 8005-12N, or 8005-22N
90
Mvcli Commands
90
Storcli Commands
91
Sas3Ircu Commands
92
Nvme Commands
93
Sensor Readings GUI Display
93
Removing and Replacing a Power Supply in the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
94
Removing a Power Supply from the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
94
Replacing a Power Supply in the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
96
Removing and Replacing Covers on an 8001-12C or 8005-12N System
96
Removing the Service Access Cover from an 8001-12C or 8005-12N System
96
Installing the Service Access Cover on an 8001-12C or 8005-12N System
97
Service and Operating Positions for 8001-12C
98
Placing an 8001-12C System into the Service Position
98
Placing an 8001-12C System into the Operating Position
100
Power Cords
101
Disconnecting the Power Cords from an 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
101
Connecting the Power Cords to an 8001-12C, 8001-22C, 8005-12N, or 8005-22N System
102
Additional Information
103
Drive Installation Details for the 8001-12C System
103
Notices
105
Servers
106
Electronic Emission Notices
108
Class a Notices
108
Trademarks
108
Class B Notices
112
Terms and Conditions
115
Advertisement
IBM Power System 8001-12C Quick Install Manual (16 pages)
Brand:
IBM
| Category:
Server
| Size: 22.24 MB
Table of Contents
System Parts
3
Miscellaneous Parts
8
Rear Ports
8
Installing and Removing
8
Advertisement
Related Products
IBM Power Systems 8005-12N
IBM Power Systems 8001-22C
IBM Power Systems 8005-22N
IBM 8038
IBM 8039
IBM 88701RX
IBM Netfinity 5100 8658 5RY
IBM iSeries 825
IBM 8648 - eServer xSeries 226
IBM 8408-E8E
IBM Categories
Server
Desktop
Storage
Laptop
Monitor
More IBM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL