Cisco Nexus 93120TX Hardware Installation Manual (76 pages)
NX-OS Mode Switch
Brand:
Cisco
| Category:
Switch
| Size: 3.9 MB
Table of Contents
Table of Contents
3
Preface
7
Audience
7
Documentation Conventions
7
Related Documentation for Cisco Nexus 9000 Series NX-OS Software
8
Documentation Feedback
10
Obtaining Documentation and Submitting a Service Request
10
Chapter 1
11
Overview
11
CHAPTER 2 Preparing the Site
17
Temperature Requirements
17
Humidity Requirements
17
Altitude Requirements
17
Dust and Particulate Requirements
18
Minimizing Electromagnetic and Radio Frequency Interference
18
Shock and Vibration Requirements
19
Grounding Requirements
19
Planning for Power Requirements
19
Airflow Requirements
21
Rack and Cabinet Requirements
21
Clearance Requirements
22
Installation Options with Rack-Mount Kits, Racks, and Cabinets
25
Installing the Chassis
25
Install a Rack
26
Unpacking and Inspecting a New Switch
26
Planning How to Position the Chassis in the Rack
27
Installing the Chassis in a Two-Post Rack
28
Attaching Center-Mount Brackets to the Chassis
28
Installing the Chassis in a Two-Post Rack
29
Installing the Chassis in a Four-Post Rack
31
Installing the Switch Using the N9K-C9300-RMK Rack-Mount Kit
31
Attaching the Bottom-Support Rails to the Rack
31
Attaching Front-Mount Brackets to the Chassis
34
Installing the Chassis in a Four-Post Rack
35
Grounding the Chassis
37
Powering up the Switch
38
CHAPTER 4 Connecting the Switch to the Network
41
Overview of Network Connections
41
Connecting a Console to the Switch
41
Creating the Initial Switch Configuration
43
Setting up the Management Interface
44
Connecting Interface Ports to Other Devices
45
CHAPTER 5 Replacing Components
47
Replacing a Fan Module During Operations
47
Replacing a Power Supply Module
49
Removing an AC Power Supply
49
Removing an HVAC/HVDC Power Supply
50
Removing a DC Power Supply
50
Installing an AC Power Supply
51
Installing an HVAC/HVDC Power Supply
52
Installing a DC Power Supply
53
Wiring a 48 V DC Electrical Connector Block
53
Rack Specifications
57
Overview of Racks
57
General Requirements for Cabinets and Racks
57
Requirements Specific to Standard Open Racks
58
Requirements Specific to Perforated Cabinets
58
Cable Management Guidelines
58
System Specifications
59
Environmental Specifications
59
Switch Dimensions
59
Switch and Module Weights and Quantities
60
Transceiver and Cable Specifications
60
Switch Power Input Requirements
60
Power Specifications
61
1200-W AC Power Supply Specifications
61
1200-W HVAC/HVDC Power Supply Specifications
61
930-W DC Power Supply Specifications
62
Power Cable Specifications
63
AC Power Cables Supported by NX-OS Mode Switches
63
HVAC/HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches
64
DC Power Cable Specifications
65
Regulatory Standards Compliance Specifications
65
Appendix
67
Fan Module Leds
68
Power Supply Leds
68
Leds
67
Switch Chassis Leds
67
Additional Kits
71
Rack Mount Kit N9K-C9300-RMK
71
Site Preparation and Maintenance Records
73
Site Preparation Checklist
73
Contact and Site Information
74
Chassis and Module Information
75
Advertisement
Cisco Nexus 93120TX Hardware Installation Manual (76 pages)
NX-OS Mode
Brand:
Cisco
| Category:
Switch
| Size: 3.83 MB
Table of Contents
Table of Contents
3
Preface
7
Audience
7
Documentation Conventions
7
Related Documentation for Cisco Nexus 9000 Series NX-OS Software
8
Documentation Feedback
10
Obtaining Documentation and Submitting a Service Request
10
Chapter 1
11
Overview
11
CHAPTER 2 Preparing the Site
15
Temperature Requirements
15
Humidity Requirements
15
Altitude Requirements
15
Dust and Particulate Requirements
16
Minimizing Electromagnetic and Radio Frequency Interference
16
Shock and Vibration Requirements
17
Grounding Requirements
17
Planning for Power Requirements
17
Airflow Requirements
19
Rack and Cabinet Requirements
20
Clearance Requirements
20
Installation Options with Rack-Mount Kits, Racks, and Cabinets
23
Install a Rack
24
Unpacking and Inspecting a New Switch
24
Planning How to Position the Chassis in the Rack
25
Installing the Chassis in a Two-Post Rack
26
Attaching Center-Mount Brackets to the Chassis
26
Installing the Chassis in a Two-Post Rack
27
Installing the Chassis in a Four-Post Rack
29
Installing the Switch Using the N9K-C9300-RMK Rack-Mount Kit
29
Attaching the Bottom-Support Rails to the Rack
29
Attaching Front-Mount Brackets to the Chassis
32
Installing the Chassis in a Four-Post Rack
32
Grounding the Chassis
35
Starting the Switch
36
CHAPTER 4 Connecting the Switch to the Network
39
Setting up the Management Interface
39
Uplink Connections
39
Downlink Connections
40
Guidelines for Connecting Ports
40
Maintaining Transceivers and Optical Cables
42
CHAPTER 5 Replacing Modules
43
Replacing a Fan Module During Operations
43
Replacing a Power Supply Module
46
Removing an AC Power Supply
46
Removing an HVAC/HVDC Power Supply
47
Removing a DC Power Supply
48
Installing an AC Power Supply
48
Installing an HVAC/HVDC Power Supply
49
Installing a DC Power Supply
50
Wiring a 48 V DC Electrical Connector Block
51
Rack Specifications
55
Overview of Racks
55
General Requirements for Cabinets and Racks
55
Requirements Specific to Standard Open Racks
56
Requirements Specific to Perforated Cabinets
56
Cable Management Guidelines
56
System Specifications
57
Environmental Specifications
57
Switch Dimensions
57
Switch and Module Weights and Quantities
58
Transceiver and Cable Specifications
58
Switch Power Input Requirements
58
Power Specifications
59
1200-W AC Power Supply Specifications
59
1200-W HVAC/HVDC Power Supply Specifications
59
930-W DC Power Supply (Port-Side Intake) Specifications
60
930-W DC Power Supply (Port-Side Exhaust) Specifications
61
930-W DC Power Supply Specifications
61
Power Cable Specifications
62
AC Power Cables Supported by NX-OS Mode Switches
62
HVAC/HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches
63
DC Power Cable Specifications
64
Regulatory Standards Compliance Specifications
65
Appendix
67
Fan Module Leds
68
Power Supply Leds
68
Leds
67
Switch Chassis Leds
67
Additional Kits
71
Rack Mount Kit N9K-C9300-RMK
71
Site Preparation and Maintenance Records
73
Site Preparation Checklist
73
Cisco Nexus 93120TX Installation Manual (68 pages)
NX-OS Mode Switch Hardware
Brand:
Cisco
| Category:
Switch
| Size: 3.43 MB
Table of Contents
Table of Contents
3
Preface
7
Audience
7
Documentation Conventions
7
Related Documentation for Cisco Nexus 9000 Series NX-OS Software
8
Documentation Feedback
10
Obtaining Documentation and Submitting a Service Request
10
Overview
11
Preparing the Site
15
Temperature Requirements
15
Humidity Requirements
15
Altitude Requirements
16
Dust and Particulate Requirements
16
Minimizing Electromagnetic and Radio Frequency Interference
16
Shock and Vibration Requirements
17
Grounding Requirements
17
Planning for Power Requirements
17
Airflow Requirements
18
Rack and Cabinet Requirements
19
Clearance Requirements
20
Installing the Chassis
23
Install a Rack
23
Unpacking and Inspecting a New Switch
24
Planning How to Position the Chassis in the Rack
25
Installing the Chassis in a Two-Post Rack
25
Attaching Center-Mount Brackets to the Chassis
25
Installing the Chassis in a Two-Post Rack
27
Installing the Chassis in a Four-Post Rack
29
Attaching the Bottom-Support Rails to the Rack
29
Attaching Front-Mount Brackets to the Chassis
30
Installing the Chassis in a Four-Post Rack
32
Grounding the Chassis
35
Powering up the Switch
37
Step
37
Connecting the Switch to the Network
41
Setting up the Management Interface
41
Uplink Connections
41
Downlink Connections
42
Guidelines for Connecting Ports
42
Maintaining Transceivers and Optical Cables
43
Replacing Modules
45
Replacing a Fan Module During Operations
45
Replacing a Power Supply Module
48
Removing an AC Power Supply
49
Removing a DC Power Supply
50
Installing an AC Power Supply
50
Installing a DC Power Supply
51
Wiring a 48 V DC Electrical Connector Block
52
Appendix A Rack Specifications
55
Overview of Racks
55
General Requirements for Cabinets and Racks
55
Requirements Specific to Standard Open Racks
56
Requirements Specific to Perforated Cabinets
56
Cable Management Guidelines
56
Appendix B System Specifications
57
Environmental Specifications
57
Switch Dimensions
57
Switch and Module Weights and Quantities
58
Transceiver and Cable Specifications
58
Power Input Requirements
58
Power Cord Specifications
58
Appendix Cleds
61
Switch Chassis Leds
61
Fan Module Leds
62
Power Supply Leds
62
Appendix D Site Preparation and Maintenance Records
65
Site Preparation Checklist
65
Contact and Site Information
67
Chassis and Module Information
67
Advertisement
Advertisement
Related Products
Cisco Nexus 93128TXNX
Cisco Nexus 93128TX
Cisco Nexus 93180YC-EX
Cisco Nexus 93180LC-EX
Cisco Nexus 93180YC-FX
Cisco Nexus 9316D-GX
Cisco Nexus 93108TC-FX3P
Cisco Nexus 93180YC-FX3
Cisco Nexus 93180YC-FX3S
Cisco Nexus 93108TC-FX
Cisco Categories
Switch
IP Phone
Network Router
Wireless Access Point
Network Hardware
More Cisco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL