Part 2: Repair Information
4. OPTICAL PARTS DISASSEMBLIES
Before taking this procedure, remove Cabinet Top, Cabinet Front and Main Board
following to the "Mechanical Disassemblies".
Disassembly requires a 2.0mm hex wrench.
4.1 Projection Lens Removal
1. Remove 4 screws (M2.5×8) and remove the Projection Lens.
4.2 Integrator Lens-In Disassembly
1. Remove 2 screws A (M2.5×5) and pull the Integrator Lens-In ass'y upward.
2. Unhook 4 stoppers B and then take the Lens off from the holder.
Fig. 2-12
A
A
Fig. 2-13
2-10
Integrator Lens
* Lens should be placed as the rugged
surface side comes to the holder side.
B
Stoppers
B