hit counter script

Installation °Rest (Duct) - LG DLEX3570 Series Owner's Manual

Dryer lg dlex3570 series/ dlex3370 series/ dlex3170 series/ dlgx3571 series/ dlgx3371 series/ dlgx3171 series
Hide thumbs Also See for DLEX3570 Series:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLAiTION
INSTRUCTIONS
29
Installation
test
(Duct)
Once you have completed
the installation
of the dryer,
use this test to make sure the condition
of the exhaust
system is adequate for proper operation
of the dryer.
This test should be performed
to alert you to any serious
problems
in the exhaust system of your home.
• Your dryer features FLOW SENSE
TM,
an innovative
sensing system that automatically
detects blockages
and restrictions
in dryer ductwork.
Keeping ductwork
clean of lint buildup
and free of restrictions
allows
clothes to dry faster and reduces energy use.
It @NOTE
The dryer should be cool before starting
this test. If
the dryer was warmed
up during
installation,
run the
AIR DRY cycle for a few minutes to reduce the interior
emperature
To activate
the
Installation
test:
1. Remove the drying
race and literature,
and then
dose the door.
Do not load anything
in the drum for this test, as in
may affect the accuracy of the results.
2. Press and hold the SIGNAL ON/OFF and TEMP.
CONTROL buttons and then
press the POWER
button.
This button
sequence activates
the
installation
test. The code _
will display if the
activation
is successful.
4, Checkthe
dispJayfor
results.
During the two minute test cycle, monitor the FLOW
SENSE
TM
display on the control
panel. If no bars
are displayed, when the cycle ends, the exhaust
system is adequate.
If the exhaust system is severely
restricted,
the display will show four bars.
Other problems
may also be shown with error codes.
Refer to the next page for error code details and
solutions.
II
NO BARS:
FOUR BARS:
OK
RESTRICTED
Four bars indicates
that the exhaust system is severely
restricted. Have the system checked
immediately,
as
performance
will be poor.
S. End of cycle.
At the end of the test cycle, _
will display.
The test cycle will end and thor
will shut off
automatically
after a short delay.
3. Press START/PAUSE button.
The dryer will start the test, which will last about
two minutes.
The heat will be turned on and the
temperatures
in the drum will be measured.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents