hit counter script
LG PQNUD1S00 Owners & Installation Manual
LG PQNUD1S00 Owners & Installation Manual

LG PQNUD1S00 Owners & Installation Manual

Power distribution indicator
Hide thumbs Also See for PQNUD1S00:

Advertisement

LG
Power Distribution
Indicator
OWNER'S & INSTALLATION MANUAL
Models: PQNUD1S00
Visit us at : http://www.lgservice.com
IMPORTANT
• Please read this user's manual completely
before installing the product.
• Installation work must be performed in
accordance with the national wiring standards
by authorized personnel only.
• Please retain this user's manual for future
reference after reading it thoroughly.
LG

Advertisement

Table of Contents
loading

Summary of Contents for LG PQNUD1S00

  • Page 1 Visit us at : http://www.lgservice.com Power Distribution Indicator OWNER'S & INSTALLATION MANUAL Models: PQNUD1S00 IMPORTANT • Please read this user's manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
  • Page 2: Table Of Contents

    Power Distribution Indicator Owner's & Installation Manual TABLE OF CONTENTS FOR YOUR RECORDS Write the model and serial numbers here: Cautions for safety ......3 Model # Overview ........6 Serial # You can find them on a label on the side of each unit. Available Watt-hour meter ..7 Dealer's Name Wiring Diagram ......10...
  • Page 3: Cautions For Safety

    Cautions for safety Cautions for safety To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
  • Page 4 Cautions for safety Don’t install it where rain falls on. Don’t install it in humid place. • Otherwise it may cause product failure. • Otherwise it may cause product failure. I WHEN USING Don’t change or extend Don’t let there exist fire heat Don’t use heat equipment electric supply wire at your near the product.
  • Page 5 Cautions for safety I WHEN USING Don’t clean the product with If water has been smeared Don’t let metallic products strong detergent of solvents on electric charge part, use of necklace, coin, key, watch but only use soft cloth. it after removing water. etc.
  • Page 6: Overview

    Overview Overview I Functions • Accumulation of total power consumption • Indication of current power in use • Indication of accumulated power for period • Indication of standby power (option setting) I Specification • Power Supply: 220~240V AC 50/60HZ 1Ø •...
  • Page 7: Available Watt-Hour Meter

    Overview I Parts of a PDI 1. Indicator LCD Display 2. Name Plate of each room 3. Menu Button 4. Up and Down Button 5. Right Shift Button 6. SHIFT Button for LCD Screen Change Available Watt-hour meter(Local purchase) • Use the digital watt meter which send the pulse signal depending on the power consumption. •...
  • Page 8: Wiring Diagram

    Wiring Diagram Wiring Diagram I Independent operation of PDI - Connect the product as shown in the below connection diagram 1. MultiV / MultiV PLUS 3Ø 380VAC or Watt meter 1Ø 220VAC Address setup Pulse type Start -> End (00) -> (03) 1Ø...
  • Page 9 Wiring Diagram I Operation with PC Central controller - Connect the product as shown in the below connection diagram. Address setup Start -> End (00) -> (03) Watt meter 3Ø 380VAC or 1Ø 220VAC PI-485 Multi/ Multi V Outdoor unit Address setup Start ->...
  • Page 10 Internal Wiring Diagram Internal Wiring Diagram I Install the product as per the following wiring diagram PI-485 Multi V Indoor unit PI-485 communications A/B or 220~240VAC MultV/MultiV PLUS A/B 1P, 50/60Hz [ A->A / B->B ] Watt meter CN-POWER WHITE BLACK The color and polarity of the communications line can differ from what’s indicated on the PCB depending on the manufacturer of watt meter.
  • Page 11: Installation

    Installation Installation How to set Option 1. You must start the key operation within 10 minutes after turning on the power for setting options. 2. When you press the Menu and Shift key at the same time, the following option screen will be shown. Initial Screen E L E C T R I C P O W E R D I S T R I B U T O R...
  • Page 12 Installation - After setting the product, press to select the next option. Press the key to set up the Option for remote reading service company LGAP selection. • Remote reading service company selection (Don't care selecting remote reading service ID.) - When two digits flash, use the L or M key to select the remote reading service company.
  • Page 13 Installation - After setting the product, press to select the next option. Press the key to set up the option for watt meter LGAP selection. • Watt meter selection - When the third 3 digits flash, use the L or M key to select the meter constant of the watt meter.
  • Page 14 Installation Press the key to select the option for standby power. LGAP • Standby power indication selection - When the forth digit flashes, use the L or M key to select the standby power. [0] NO-STBP -> Does not show the standby power [1] CAL-STEP ->...
  • Page 15 Installation LGAP 3. After setting the option, press the Shift key to enter the remote reading service ID setup mode. (In case of selecting reading service ID in ) • This function is applicable to only korean marcket (Domestic) So, skip this setting in the procedure for overseas marcket Press the "SHIFT"...
  • Page 16: Initial Screen

    Installation Press the Shift key to enter the indoor selection mode Initial Screen ( S t a r t ) - > ( E n d ) ( 0 0 ) - > ( 0 0 ) LGAP • You can select the option for indoor address selection mode only when Master / Slave is selected.
  • Page 17: How To Set Interface Unit

    How to set Interface unit How to set Interface unit PI-485 Selection air- Selection conditioner type network type ON KSDO 4H & MPS MULTI Products Configuration Methods ON KSDO4H 1.4 ON + ALL OFF: & MPS Non-Inverter Product applied Common PCB &...
  • Page 18: How To Set Each Indoor Unit

    How to set each Indoor Unit How to set each Indoor Unit I Using wired remote controller 1. Press the "Program" & AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp "Set/Clr" keys at the same AUTO Heater Preheat Defrost Humidify...
  • Page 19 How to set each Indoor Unit I Using wireless remote controller 1. Address setting mode 1) With the top left key pressed, press the Reset button. (Press the left key for more than 3 second) 2) Using the temperature adjustment key, set up the indoor unit address ❉...
  • Page 20: Installation Guide

    Installation Guide Installation Guide Power Distribution Indicator and WHM should be installed in the specified cabinet which can protect the Power Distribution Indicator from water and humidity. EX1) EX2) EX3) EX4) ✱ NOTE : WHM (Watt-hour meter) • Suppl power after completing the Wiring •...
  • Page 21: Usage

    Usage Usage (The distributed power consumption is based on current operating condition) • Press the Menu key once to display the current power consumption. • Consecutively press the Menu key to switch the screen. • The PDI will operate normally after 3 minutes, when all options are set . 1.
  • Page 22 Usage • When selecting the option for classifying the stand by power, the stand by power is displayed in the last page. The stand by power page P W R D i s t ( 0 0 ) 0 0 0 0 . 0 S T B P : 0 0 0 0 .
  • Page 23 Usage 3. Period accumulated power distribution mode • It displays the power consumption of each indoor unit (Kwh) • When 1-2 indoor units are connected, only 1 page is displayed. • When 4 or more indoor units are connected, press the Shift key to check the next page. Total SUM Value P e r i d A C C M ( 0 1 ) X X X X .
  • Page 24 Memo 24 Electricity Distribution Indicator...
  • Page 25 (L'assorbimento della potenza distribuita si basa sulle condizioni operative correnti) • Premere il tasto del Menu per visualizzare l'assorbimento corrente della potenza. • Successivamente premere il tasto di menu per cambiare la schermata. • Il PDI funzionerà normalmente per 3 minuti, quando tutte le impostazioni sono state configurate. 1.
  • Page 26 • Quando si seleziona l'opzione per la classificazione dell'alimentazione di standby, l'alimentazione di standby viene visualizzata sull'ultima pagina. La pagina dell'alimentazione di standby P W R D i s t ( 0 0 ) 0 0 0 0 . 0 S T B P : 0 0 0 0 .
  • Page 27 3. Modalità distribuzione potenza accumulata sul periodo • Visualizza il consumo di potenza di ciascuna unità interna (Kwh) • Quando sono connesse 1-2 unità interne, solo la pagina 1 viene visualizzata. • Quando sono connesse 4 o più unità interne, premere il tasto Maiusc per vedere la pagina successiva. Valore complessivo SOMMA P e r i d A C C M ( 0 1 ) X X X X .
  • Page 28 Nota 24 Indicatore distribuzione elettrica...

Table of Contents