hit counter script
Mitsubishi Electric PUMY-P112 Installation Manual
Mitsubishi Electric PUMY-P112 Installation Manual

Mitsubishi Electric PUMY-P112 Installation Manual

Hide thumbs Also See for PUMY-P112:

Advertisement

Air-Conditioners
PUMY-P112, P125, P140VKM
PUMY-P112, P125, P140YKM

INSTALLATION MANUAL

For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung
und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
intérieur pour une utilisation sûre et correcte.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior
antes de instalar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d'installazione dell'unità
interna prima di installare il condizionatore d'aria.
EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ
Για σωστή και ασφαλή χρήση, διαβάστε προσεκτικά αυτό το εγχειρίδιο καθώς και το εγχειρίδιο εγκατάστασης
της εσωτερικής μονάδας, προτού εγκαταστήσετε τη μονάδα του κλιματιστικού.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
interior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan luftkonditioneringen installeras
så att den används på ett säkert och korrekt sätt.
MONTAJ ELKİTABI
Emniyetli ve doğru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve iç ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство
и руководство по установке внутреннего прибора перед установкой кондиционера.
For use with R410A
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Eλληνικά (GR)
Português (P)
Dansk (DA)
Svenska (SW)
Türkçe (TR)
Русский (RU)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PUMY-P112

  • Page 1: Installation Manual

    Air-Conditioners PUMY-P112, P125, P140VKM PUMY-P112, P125, P140YKM For use with R410A INSTALLATION MANUAL FOR INSTALLER English (GB) For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch (D) Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung...
  • Page 2: Table Of Contents

    This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
  • Page 3 1. Safety precautions 1.1. Before installation Caution: • When installing the unit in a hospital or communications office, be prepared for • Do not use the unit in an unusual environment. If the air conditioner is installed in areas exposed to steam, volatile oil (including machine oil), or sulfuric gas, noise and electronic interference.
  • Page 4: Installation Location

    You should note that indoor units that can be connected to this outdoor unit are the following models. • Indoor units with model numbers 15-140 (PUMY-P112:15-125) can be connected. Refer to the table 1 below for possible room, indoor unit combinations.
  • Page 5: Installation Location

    . Installation location 2.5. Ventilation and service space 2.5.2. When installing multiple outdoor units Leave 25 mm space or more between the units. 2.5.1. When installing a single outdoor unit 1 Obstacles at rear only (Fig. 2-9) Minimum dimensions are as follows, except for Max., meaning Maximum dimen- 2 Obstacles at rear and above only (Fig.
  • Page 6: Installing The Outdoor Unit

    . Installation location 2.5.3. Windy location installation When installing the outdoor unit on a rooftop or other location unprotected from the wind, situate the air outlet of the unit so that it is not directly exposed to strong winds. Strong wind entering the air outlet may impede the normal airflow and a malfunction may result.
  • Page 7 4. Installing the refrigerant piping (mm) A+B+C+D+a+b+c+d+e 300 m L = A+B+C+D+e 150 m È Liquid pipe É Gas pipe PUMY-P112-140 ø9.52 ø15.88 ℓ = B+C+D+e 30 m 50 m (Outdoor lower H 40 m) B, C, D (mm) 15 m Ê Total capacity of indoor units È...
  • Page 8 4. Installing the refrigerant piping 4.3. Refrigerant piping (Fig. 4-4) Remove the service panel D (three screws) and the front piping cover A (two screws) and rear piping cover B (two screws). 1 Perform refrigerant piping connections for the indoor/outdoor unit when the outdoor unit’s stop valve is completely closed.
  • Page 9: Additional Refrigerant Charge

    4. Installing the refrigerant piping Precautions when using the charge valve (Fig.4-8) Do not tighten the service port too much when installing it, otherwise, the valve core * The figure to the left is an example could be deformed and become loose, causing a gas leak. only.
  • Page 10 Outdoor unit controller – Cable diameter 0.3 to 1.25 mm (0.75 to 1.25 mm PUMY-P112 1 to 9 units per 1 OC When 10 m is exceeded, use cable with the Indoor unit controller PUMY-P125 1 to 10 units per 1 OC Remarks same specifications as 1. Wiring transmission...
  • Page 11: Wiring Of Main Power Supply And Equipment Capacity

    6. Electrical work <Permissible Lengths> 1 M-NET Remote controller • Max length via outdoor units: and L and L 500 m (1.25 mm or more) • Max transmission cable length: L and L and L and L and L and L 200 m (1.25 mm or more) • Remote controller cable length: ℓ...
  • Page 12 6. Electrical work Indoor unit PLFY-VBM, PMFY-VBM, PEFY-VMS, Type 1 18.6 PCFY-VKM, PKFY-VHM, PKFY-VKM Type 2 PEFY-VMA Type 3 PEFY-VMHS 13.8 Sample chart Others Other indoor unit 6000 C : Multiple of tripping current at tripping time 0.01s Please pick up “C” from the tripping characteristic of the breaker. SAMPLE <Example of “F2” calculation>...
  • Page 13: Test Run

    7. Test run 7.1. Before test run ► After completing installation and the wiring and piping of the indoor and 3. After connecting the wires to the compressor, the compressor will start to warm outdoor units, check for refrigerant leakage, looseness in the power supply up after power is supplied.
  • Page 14 EG-DEKLARATION OM ÖVERENSSTÄMMELSE EY-VAATIMUSTENMUKAISUUDEN VAKUUTUS EG-CONFORMITEITSVERKLARING MITSUBISHI ELECTRIC CORPORATION, SHIZUOKA WORKS 18-1, OSHIKA 3-CHOME, SURUGA-KU, SHIZUOKA-CITY 422-8528, JAPAN hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
  • Page 15 EG-DEKLARATION OM ÖVERENSSTÄMMELSE EY-VAATIMUSTENMUKAISUUDEN VAKUUTUS EG-CONFORMITEITSVERKLARING MITSUBISHI ELECTRIC CORPORATION, SHIZUOKA WORKS 18-1, OSHIKA 3-CHOME, SURUGA-KU, SHIZUOKA-CITY 422-8528, JAPAN hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
  • Page 16 <ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idioma original. CAUTION CUIDADO • Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1. •...
  • Page 17 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V BH79D391H01 Printed in Japan...

Table of Contents