ELEC
STARTING SYSTEM
STARTER RELAY
1. Inspect:
Brown lead terminal
Black lead terminal
Loose → Tighten.
2. Check:
Relay operation
Does not function → Replace.
Checking steps:
Connect the tester between the termi-
nals of the starter relay as shown.
Connect a 12 V battery.
Brown lead 1 → Positive terminal
Black lead 2 → Negative terminal
Check that there is continuity between
the starter relay terminals.
FUSE
1. Check:
Fuse
Blown → Replace.
Fuse rating:
12 V - 10 A
8-21
E