52. OSM OBITER
Function
Each time OSM is displayed, OSM is shifted in order to
reduce the glare on the screen during OSM display.
Transmit Data
DFH 80H 60H 5FH 01H DATA00 CKS
DATA00 01H : obiter on
02H : obiter off
ACK
DFH 80H 60H 5FH 01H DATA00 CKS
DATA00 01H : obiter on
02H : obiter off
53. Input Skip
Function
When there is no signal in the input switch key on the
monitor side, it skips to the next channel.
Transmit Data
DFH 80H 60H 5FH 01H DATA00 CKS
DATA00 01H : on
02H : off
ACK
DFH 80H 60H 5FH 01H DATA00 CKS
DATA00 01H : on
02H : off
54. SERIAL No. Request
Function
The external control apparatus read out the serial number
of the set that is entered into the EEPROM of the plasma
display.
Transmit Data
1FH 80H 60H 15H 00H CKS
ACK
The plasma display returns the following ACK.
7FH 60H 80H 15H 0CH DATA00–DATA11 CKS
DATA00–DATA11are set as follows.
Set value 00H–09H : 0–9
96H
: blank (no display)
10H–29H : alphabet A–Z
RS-232C Adjustment Mode
55. S1/S2 SELECT
Function
The external control apparatus switches between the S1/
S2 detection function setting of the plasma display.
Transmit Data
DFH 80H 60H 89H 01H DATA00 CKS
DATA00 01H : auto
02H : off
ACK
The plasma display returns the following ACK.
7FH 60H 80H 89H 01H DATA00 CKS
DATA00 01H : auto
02H : off
56. SOFT FOCUS
Function
The external control apparatus switches the SOFT FOCUS
function setting of the plasma display.
Transmit Data
DFH 80H 60H 65H 01H DATA00 CKS
DATA00 01H : off
02H : 1
03H : 2
04H : 3
05H : 4
ACK
The plasma display returns the following ACK.
7FH 60H 80H 65H 01H DATA00 CKS
DATA00 01H : off
02H : 1
03H : 2
04H : 3
05H : 4
77