3. Fuser section

3-1. Fuser unit removal

1 Open the front panel
2 Remove the table glass.
3 Turn the open/close lever to the right and open the upper unit
slowly.
4 Remove the connectors (2 pin × 2), slightly lift the right side of the
unit and pull it out.
5 Move the copy lamp unit to the left of the body (the paper exit
side).
6 Disconnect the connector (2-pin) of the dehumidifier heater which
extends from the dark box cover. Insert a long screwdriver (+) into
that port and remove the screw which is fixing the fuser cover.
7 Remove the fuser cover in the direction of arrow
A
.
A
8 Remove an E-ring and two connectors.

3-2. Heater lamp replacement

1 Remove the fuser cover fixing screw (1 pc.), and slide it to the
front side, and remove it.
2 While pushing the projection of the Faston terminal connected to
the thermostat, remove the lead wire from the connected section.
3 Remove the lamp holder fixing screw on the top of the rear frame,
and remove the holder.
4 Pull out the heater lamp from the front frame.
For assembly, reverse the disassembly procedures.