Configurable Zone Type Programming (*83 Menu Mode)

Start Configurable Zone Type Programming Mode by pressing ∗ 83 while in Data Programming mode.
PROMPT
E n t e r Z o n e T y p e
( 0 0 = q u i t )
9 0
9 0 Z n A t t r i b u t e s
0
9 0 B y p a s s O p t i o n
0
9 0 R e s p t o S h o r t
A r m e d 0
D A r m d 0
9 0 R e s p t o o p e n
A r m e d 0
D A r m d 0
9 0 V e n t Z o n e
0 = N o , 1 = Y e s
9 0 A l m / T r b l P r o c
0
VALID ENTRIES
Zone Type Number
90-93 = zone type
[∗] to continue
Zone Attributes
0 = none
1 = exit delay only
2 = entry/exit 1
3 = entry/exit 2
4 = follows entry/exit
5 = has verification (resets
power upon event and when
code + OFF to clear condition. If
condition persists, zone
activates)
6 = resettable (upon code + OFF)
[∗] to continue
Bypass Option
0 = zone type cannot be
bypassed
1 = auto bypassed when armed
in stay mode
[∗] to continue
Response to Shorts
0=none
2=trouble
1=Alarm
3=fault
[∗] to continue
Response to Opens
0 = none
2 = trouble
1 = Alarm
3 = fault
[∗] to continue
Vent Zone?
0=no
1=yes
[∗] to continue
Alarm/Trouble Processing
0=none
1=Zone type has automatic
restore
2=zone type uses Misc. Fault
Delay Time and automatic
restore
[∗] to continue
EXPLANATION
Enter the configurable zone type number being
programmed.
Enter the desired zone attributes.
NOTE: If 6 is selected for the Zone Attribute,
enter 0 for Alarm/Trouble Processing at the below
Alm/Trbl Proc prompt.
Enter the desired bypass option.
Select the type of response when zones assigned to
this zone type are shorted when the system is
armed.
NOTES: 1. For double-balanced zones, this entry
must be 0.
2. For zone-doubled zones, both zones of
the doubled pair must be assigned the
same response to a short.
Select the type of response when zones assigned to
this zone type are opened when the system is
armed.
If selected, the system can be armed even if zones
assigned to this zone type are faulted.
NOTE: After arming, faults on these zones will be
ignored until the zone is restored.
Select desired actions for zones assigned to this
zone type.
Option 2: Select Miscellaneous Fault Delay in
field *87.
NOTE: If 6 was selected above for the Zone
Attribute, enter 0 for this prompt.
5-22