BEFORE OPERATION

Read section titled "SAFETY" (pages 4 – 7).
Make sure of the followings before operation.

WORKING ENVIRONMENT

WARNING
● No flammable gas, liquid or other
flammable objects at worksite.
● Clear the area of children or
unauthorized personnel.

AIR SUPPLY

DANGER
WARNING
● Never connect Nailer to pressure which
potentially exceeds 200 psi (13.7 bar
14 kgf/cm
2
).
● Never use non relieving coupler on
Nailer.
1.
Power source
Use only clean, dry, regulated
compressed air as a power source for
this Nailer.
Air compressors used to supply
compressed air to this Nailer must
comply with the requirements of the
latest version of ANSI Standard B 19.3
"Safety Standard For Compressors For
Process Industries".
Moisture or oil in the air compressor may
accelerate wear and corrosion in the
Nailer.
Drain daily.
● NEVER use oxygen or
other
bottled
gases. Explosion may
occur.
2.
Filter-Regulator-Lubricator
Use a regulator with a pressure range of
0 – 120 psi (0 – 8.3 bar 0 – 8.5 kgf/cm
Filter-regulator-lubricator units supply
an optimum condition for the Nailer and
extend the Nailer life.
These units should always be used.
Filter ............ The
moisture and dirt mixed in
compressed air.
Drain daily unless fitted
with an automatic drain.
Keep the filter clean by
regular maintenance.
Regulator .... The regulator controls the
operating pressure for safe
operation of the Nailer.
Inspect the regulator
before operation to be sure
it operates properly.
Lubricator ... The lubricator supplies an
oil mist to the Nailer.
Inspect the lubricator
before operation to be sure
the supply of lubricant is
adequate.
Use Hitachi pneumatic tool
lubricant.
Nailer
Side
Lubricator
3.
Air hose
Air hose must have a minimum working
pressure rating of 150 psi (10.4 bar 10.6
2
kgf/cm
) or 150% of the maximum
pressure produced in the system,
whichever is higher.
4.
Air consumption
Using the Air consumption table and the
Air compressor size formula, find a
correct compressor size.
English
2
).
filter
removes
Regulator
Compressor
Side
Filter
11