1-9-7. DCP-31/1 Board
Switches
Ref. No.
Name
S1
ENG Disable Select
S2
Character Select
_
S4-1
S4-2
Remote Connector
S4-3
VF CAM Select
S4-4
CAM Mode
_
S4-5 to 7
S4-8
Data reset
DNW-7/90/90WS
C
D
B
S2
A
S1
S4
DCP-31/1 A Side
Description
ON : Disables
OFF : Enables
Selects whether to display the character
on the viewfinder and TEST OUT connector.
1: Both viewfinder and TEST OUT connector
2: Viewfinder only
3: TEST OUT connector only
(For the character to be displayed on neither
the viewfinder nor TEST OUT connector,
set off the DISPLAY switch of the viewfinder.)
Factory use
ON : Connects except RM-P9 and VA-DN1.
OFF : Connects RM-P9 or VA-DN1.
ON : Outputs the camera signal on the viewfinder
when the OUTPUT switch is set BARS.
OFF : Outputs the color bars signal on the viewfinder
when the OUTPUT switch is set BARS.
OFF : Uses the VTR START button as the INCOM
TALK ON button.
ON : Uses the VTR START button as the RET 2
button.
(When S4-4 is set ON, use the VTR SAVE/STBY
switch as the INCOM TALK ON button.)
Not used
ON : Resets in the setting menu
when the power is turn on.
OFF : Uses in normal times.
1-9. Switch/Slit Land Settings on the Boards
E
F
1
2
3
4
5
6
Factory setting
OFF
2
OFF
OFF
OFF
OFF
OFF
OFF
1-9-7. DCP-31/1 Board
1-23