These log messages refer to the TIMESYNC (Firewall time synchronization events) category.

2.31.1. synced_clock (ID: 03500001)

Default Severity
Log Message
Explanation
Gateway Action
Recommended Action
Revision
Parameters
2.31.2. failure_communicate_with_timeservers (ID:
03500002)
Default Severity
Log Message
Explanation
Gateway Action
Recommended Action
Revision

2.31.3. clockdrift_too_high (ID: 03500003)

Default Severity
Log Message
Explanation
Gateway Action
Recommended Action
NOTICE
The clock at <oldtime>, was off by <clockdrift> second(s) and
synchronized with <timeserver> to <newtime>
The clock has been synchronized with the time server.
None
None.
2
oldtime
newtime
clockdrift
timeserver
WARNING
Communication with the timeserver(s) failed. Clock not updated.
The unit failed to establish a connection with the time sync server. The
clock has not been updated.
clock_not_synced
Verify that the time sync server is running.
1
WARNING
According to the timeserver the clock has drifted <clockdrift>
seconds(s) which is NOT in the allowed correction interval
(+/-<interval> seconds)
The clock has drifted so much that it is not within the allowed +/-
correction interval. The clock will not be updated.
clock_not_synced
If the correction interval is too narrow, it can be changed in the
Advanced Settings section.