hit counter script
Bosch HBN456AUC Installation Instructions Manual

Bosch HBN456AUC Installation Instructions Manual

Electric built-in single & double oven
Hide thumbs Also See for HBN456AUC:
Table of Contents

Advertisement

Available languages

Available languages

BOSCH
INSTALLATION
INSTRUCTION
MANUAL
for
Bosch Electric
Built-in
Single & Double Oven Models HBN 44../45../46..
MANUEL
D'INSTALLATION
four 61ectrique
Bosch encastr6,
simple et double
Models HBN 44../45../46..
Ed. 01-02

Advertisement

Table of Contents
loading

Summary of Contents for Bosch HBN456AUC

  • Page 1 BOSCH INSTALLATION INSTRUCTION MANUAL Bosch Electric Built-in Single & Double Oven Models HBN 44../45../46.. MANUEL D'INSTALLATION four 61ectrique Bosch encastr6, simple et double Models HBN 44../45../46.. Ed. 01-02...
  • Page 3 BOSCH INSTALLATION INSTRUCTION MANUAL Bosch Electric Built-in Single & Double Oven Models HBN 44../45../46.. BEFORE YOU BEGIN, READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY IMPORTANT: Save these instructions for the local electrical inspector's INSTALLER: Please leave this manual with owner for future reference.
  • Page 4: Table Of Contents

    Table of Contents INTRODUCTION ..........................TOOLS YOU WILL NEED ......................POWER REQUIREMENTS ....................... CHOOSING OVEN LOCATION ....................STEPS FOR INSTALLATION ....................TECHNICAL DATA ......................... SINGLE OVEN ..........................DOUBLE OVEN .......................... UNDERCOUNTER INSTALLATION ..................SINGLE OVEN ..........................WALL INSTALLATION ......................... SINGLE OVEN ..........................
  • Page 5: Introduction

    INTRODUCTION a 208 volt circuit must be used, wiring inside oven must be modified. See Connection to a 208 Volt Circuit, in this manual. A circuit breaker Please read these instructions COMPLETELY time-delay fuse sized not to exceed the circuit rat- AND CAREFULLY.
  • Page 6: Single Oven

    TECHNICAL DATA SINGLE OVEN For cutout dimensions see following sections titled: Preparing Location Electrical Ratings and Maximum Connected Load Convection Single Oven Models Oven Watts Volts Hertz Amperes @240V/208V @240V/208V HBL 442A UC 240/208 13.5/13.6 3,250/2,820 HBL 445A UC 240/208 13.5/13.6 3,250/2,820 HBL 446A UC...
  • Page 7: Undercounter Installation

    UNDERCOUNTER INSTALLATION, SINGLE Oven electrical supply: Locate junction box in adjacent cabinet or below bottom support surface. 25-3/8" opening width ¥ Bottom support surface must be solid level and able to support at least of 150 Ibs, !/4' min. distance between oven door frame and adjacent...
  • Page 8: Wall Installation

    WALL INSTALLATION, SINGLE OVEN 25-3/8" opening width Electrical o=¢ supply junction Note: l. Do not slide oven across floor. Dam- 6. Be careful when placing oven. age to floor covering or floor could re- pinch the conduit between sult. oven back or wall and the inner cabi- net wall or floor.
  • Page 9: Double Oven

    WALL INSTALLATION, DOUBLE OVEN Secure oven to cabinet usingthe screws provided. Screws should inserted through mounting holes positions indicated in the frame (open door to see frame and mounting holes). Do not overtighten screws, Note: 1. Do not slide oven across floor.
  • Page 10: Electrical Supply

    ELECTRICAL SUPPLY WIRING REQUIREMENTS When making the wire connections, use the entire length of the conduit provided (3 feet). The con- Before installing the oven have a qualified electri- duit must not be cut. cian verify that your home is provided with ade- Before making connections...
  • Page 11: Connecting To 208 Volt Circuit

    To connect to 208 volt circuit: CONNECTING TO 208 V CIRCUIT Remove the access panel(s) located on the ovens are pre-wired for connection to 240 back of the oven(s). volt, 60 Hertz supply. If connecting to a 208 volt, Loosen the first and second screws in the ter- 60 Hz.
  • Page 12: Electrical Connections

    3-WIRE BRANCH CIRCUIT ELECTRICAL CONNECTIONS Refer to Figure A, where local codes allow connection of GROUND wire from the oven to This appliances is manufactured with a green GROUND wire connected to the oven chassis. the branch circuit NEUTRAL wire (grey or white colored wire): After making...
  • Page 13: Final Checklist

    FINAL CHECK LIST you have modified the oven(s) for use on 208 volt the voltage reading between the black and red wires should be 190 to 208 volts. To prevent improper connections leading to dam- time by pressing age of electrical components and so voiding Clock button...
  • Page 15 BOSCH MANUEL D'INSTALLATION four 61eetrique Bosch eneastr6, simple et double Models 44../45../46.. VEUILLEZ LIRE ATTENTIVEMENT CE MANUEL AVANT DE COMMENCER L'INSTALLATION IMPORTANT: Conservez ce manuel pour l'inspecteur 61ectrique local. INSTALLATEUR: Veuillez remettre ce manuel au propri6taire de l'appareil pour r6f6rence.
  • Page 16 Table des mati_res INTRODUCTION ..........................OUTILS DONT VOUS AUREZ BESOIN ................SPECIFICATIONS ELECTRIQUES REQUISES ..............CHOIX DE L'EMPLACEMENT DU FOUR ................ETAPES DE L'INSTALLATION ....................DONNI_ES TECHNIQUES ......................FOUR SIMPLE ..........................FOUR DOUBLE .......................... INSTALLATION SOUS LE COMPTOIR ..................FOUR SIMPLE ...........................
  • Page 17: Introduction

    INTRODUCTION une source de courant alternatif (C.A.) separde, par un circuit/_ trois ou quatre ills/_ phase unique, 240 volts, 60Hz. Si vous devez utiliser un circuit Veuillez lire enti_rement et attentivement les in- de 208 volts, il faut absolument modifier le filage structions contenues...
  • Page 18: Donni_Es

    DONNI_ES TECHNIQUES FOUR SIMPLE Pour les dimensions, rdfdrez-vous _ la section intitulde Prdparation de l'emplacement Spdcifications dlectriques Four it Mod61es charge dlectrique maximale convection four simple Watts Volts Hertz Amperes 240V/208V 240V/208V HBN 442A UC 240/208 13.5/13.6 3,250/2,820 HBN 445A UC 240/208 13.5/13.6 3,250/2,820...
  • Page 19: Installation Sous Le Comptoir

    INSTALLATION SOUS LE COMPTOIR, FOUR SIMPLE Alimentation en electrique du four: Localisez la bo'ite de derivation dans larmoire adjacente ou sous la surface de support inferieure, 25-3/8' Largeur de Iouverture La surface de support inferieure dolt @re solide, de niveau et capable supporter au moins !50 Ibs,...
  • Page 20: Installation Murale

    INSTALLATION MURALE, FOUR SIMPLE de Pouverture 25-3/8" Large © Fixez le four a I'armoire a I'aide des vis fournies. Les vis doivent 8tre ins6r6es dans les trous montage, dans les positions indiqu6es sur le ca- dre (ouvrez la porte pour voir le cadre et les trous de montage).
  • Page 21: Four Double

    INSTALLATION MURALE, FOUR DOUBLE Fixez le four & larmoire & laide des vis fournies. Les vis doivent @re inserees dans les trous montage, dans les positions indiquees sur le ca- dre (ouvrez la porte pour voir le cadre et les trous de montage).
  • Page 22: Alimentation En I_Lectriciti

    ALIMENTATION FILS I_LECTRIQUES REQUIS I_LECTRICITI_ Lors des connexions des ills de votre appareil, tilisez toute la longueur du conduit electrique foumi (3 pieds). Ne coupez pas ce conduit. Avant d'installer le four, demandez /_ un electri- Avant de brancher l'appareil/_ la source d'electri- cien qualifie...
  • Page 23: Connexiona Un Circuita 208 Volts

    CONNEXION A UN CIRCUIT Pour une telle connexion, effectuez ce qui suit: 208 VOLTS Enlevez le(s) panneau(x) d'accas situes l'arriare du(des) four(s). tours sont equipes filage pour Devissez legarement premiare connexion /_ un circuit de 240 volts, 60 Hz. Si deuxiame vis du bloc du terminal, tel qu'il-...
  • Page 24: Les Connexions I_Lectriques

    CIRCUIT A 3 FILS LES CONNEXIONS I£LECTRIQUES Refdrez-vous/_ la figure A pour laquelle les codes et rbglements, locaux permettent la connexion du Ce four est fourni avec un fil electrique de MISE fil de MISE A LA TERRE du four au fil du cir- LA TERRE vert, rattache au chfissis.
  • Page 25: Liste De ¥1_Rification

    LISTE DE VITRIFICATION FINALE avez modifie le tour pour un circuit de 208 volts, la lecture doit alors atre entre 190 et Afin d'eviter toute connexion incorrecte pouvant 208 volts. causer des dommages aux composantes electri- Reglez l'horloge en appuyant sur le bouton ques et entrainer...
  • Page 28 Code 09BH0300 TPS Gallarate- (02-001)

Table of Contents