DIGITAL VIDEO RECORDER
DIGITAL VIDEO RECORDER
3
GB
System Connection for Alarm Recording
<Rear Side Connection Terminal of SHR-1010>
1
2
3
4
5
6
ALARM IN
1
2
GND
3
ALARM OUT
4
ALARM RESET IN
5
GND
1 SHOT REC IN
6
7
REC START IN
GND
8
9
REC END
TRIGGER OUT
10
Alarm recording is a function for recording the input video when an alarm signal is input
while a device with alarm output is connected to this unit.
Connect to the corresponding terminals, as the numbers may be different for external
devices.
For external devices, if the alarm input (ALARM INPUT) and alarm cancel (ALARM
CANCEL) are not available, you can leave them unconnected.
2-3
<Outside Product>
7
8
9
10
1
2
3
4
5
GND
1
2
TRIGGER IN
ALARM IN
3
4
ALARM CANCEL
ALARM OUT
5
4
Connection with PC for Use
Connection with RS-232C
You can control the system remotely through the parallel communication of RS-232.
Data Code: ASCII Code
Data Transmission Method : Start-Stop Asynchronized Serial Interface
Protocol: 8 bit Data, 1 Stop bit, None Parity
Transmission speed: 4800, 9600, 19200, 38400 bps
RS-232 Port behind SHR-1010 System
GB
2
TXD (Transmitted Data)
3
RXD (Received Data)
5
SG (Signal Ground)
1, 4, 6~9
NO Connection