hit counter script
AEG AGN2400B Original Instructions Manual

AEG AGN2400B Original Instructions Manual

Portable generator set agn2400b

Advertisement

AGN2400B
PORTABLE GENERATOR SET
Original Instructions

Advertisement

Table of Contents
loading

Summary of Contents for AEG AGN2400B

  • Page 1 AGN2400B PORTABLE GENERATOR SET Original Instructions...
  • Page 2 carburetor circuit breaker drain screw Fig. 1 Fig. 2 fuel tank fuel cap fuel level gauge choke lever filter fuel valve recoil oil cap/ dipstick starter grip Fig. 3 fuel fuel tank fuel cap level gauge oil cap/ oil cap/ dipstick dipstick oil fill hole...
  • Page 3 recoil starter grip Fig. 6 to start (choke closed) choke lever CHOKE to run (choke open) fuel valve Fig. 7 Fig. 8 filter elements latches air filter unit filter cover Fig. 9...
  • Page 4 oil cap/ dipstick Fig. 10 spark plug fuel valve filter o-ring sediment spark plug Fig. 11 Fig. 12 fuel fuel line valve barb Fig. 13...
  • Page 5 English INTRODUCTION Do not touch bare wire or receptacles. Do not use the generator with electrical cords which are This product has many features for making its use more pleasant worn, frayed, bare, or otherwise damaged. and enjoyable. Safety, performance, and dependability have Before storing, allow the engine to cool.
  • Page 6 English spECIfIC sAfETy RULEs Keep children a minimum of 10 feet away from the generator at all times. WARNING: The unit operates best in temperatures between 5°C and When this generator is used to supply a building 40°C with a relative humidity of 30~95%. wiring system: the generator must be installed by Do not operate the generator at altitudes above 1000m.
  • Page 7 English symBOLs Some of the following symbols may be used on this tool. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the tool better and safer. symBOL NAmE DEsIGNATION/EXpLANATION Volts Voltage Amperes Current Hertz...
  • Page 8 English...
  • Page 9 English...
  • Page 10 English CAUTION: ELECTRICAL Do not overload the generator’s capacity. Exceeding the generator’s wattage/amperage capacity can damage the GENERATOR CApACITy generator and/or electrical devices connected to it. Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you will power at the Typical Typical Continuous*...
  • Page 11 English fEATUREs model AGN2400B AC Output AC Frequency (Hz) AC Output voltage (V) Rated AC Output (W) 2,000 Rated Current (A) Circuit Breaker (A) Power Factor DC Output Volts Amps Engine Engine Number UP168 Engine Type 4-Stroke; air-cooled OHV; Gasoline...
  • Page 12 English fEATUREs RECEpTACLEs Your generator has the following single phase, 50 Hz outlets: one 230 Volt AC, 16 Amp receptacle. These can be used for KNOW yOUR GENERATOR operating appropriate appliances, electrical lighting, tools, and See Figure 3. motor loads. The safe use of this product requires an understanding of the information on the product and in this operator’s manual as well RECOIL sTARTER GRIp...
  • Page 13 English WARNING: WARNING: If any parts are damaged or missing do not operate Do not use any attachments or accessories not this product until the parts are replaced. Failure to recommended by the manufacturer of this product. heed this warning could result in serious personal The use of attachments or accessories not injury.
  • Page 14 English UsING fUEL sTABILIsER Connecting the battery cables: Before connecting the battery charging cables to Fuel gets old, oxidizes, and breaks down over time. Adding a a battery that is installed in a vehicle, disconnect the fuel stabiliser extends the usable life of fuel and helps prevent vehicle ground battery cable from the battery negative (-) deposits from forming that can clog the fuel system.
  • Page 15 English sTOppING THE ENGINE CHANGING ENGINE OIL See Figures 6- 7. See Figure 10. To stop the engine under normal operating conditions: Remove the oil cap/dipstick. Place a container underneath the oil drainage bolt to Remove any load from the generator. collect used oil as it drains.
  • Page 16 English CLEANING THE EXHAUsT pORT AND mUffLER DRAINING THE CARBURETOR See Figure 2. Depending on the type of fuel used, the type and amount of oil used, and/or your operating conditions, the exhaust port Turn the engine switch off ( O ). and muffler may become blocked with carbon deposits.
  • Page 17: Maintenance Schedule

    English mAINTENANCE sTORAGE When preparing the generator for storage, follow the guidelines below. sTORAGE TImE pRIOR TO sTORING No special preparation is required. Less than 1 month Empty fuel from fuel tank. 1 to 2 months Empty fuel from fuel tank. 2 months to 1 year Drain fuel from carburetor.
  • Page 18 English mAINTENANCE pROBLEm pOssIBLE CAUsE sOLUTION Engine will not start. Engine switch is OFF. Turn engine switch to ON. No fuel. Fill fuel tank. Oil level is low. Check engine oil level and fill, if necessary. Turn fuel valve ON. Fuel valve is OFF.
  • Page 19 English...
  • Page 20: Limited Warranty

    LImITED WARRANTy TTI warrants this outdoor product to be free of defects in material and workmanship for 24 months from the date of purchase by the original purchaser, subject to the limitations below. Please keep your invoice as proof of date of purchase. This warranty is only applicable where the product is used for personal and non-commercial purposes.
  • Page 21 Tsuen Wan, Hong Kong. Tel.: (+45) 43 56 55 55 Tel : + 852 2402 6888 Fax: (+45) 43 56 55 56 Machine: portable Generator set Type: AGN2400B Name of company: Homelite Far East Co., Ltd. Name / title: Sven Eschrich Address:...

Table of Contents