Instruction Manual SF450EN
Carbon Monoxide Alarm
User Manual 2109M5500_5
EN50291:2001
INTRODUCTION
Thank you for purchasing this
Green
Red
alarm which is designed to
Power
Test
Alarm
detect the presence of Carbon
light
Button
light
Buzzer
Monoxide. This manual contains
information on the installation
and operation of the Carbon
Monoxide alarm.
The green power light flashes at
approximately 1 minute intervals
to indicate that the unit is
operating correctly. The red alarm
light will flash continuously and
the buzzer will sound if Carbon Monoxide is present.
The unit is suitable for use in areas where cooking and heating
appliances burn fuels such as wood, charcoal, coal, coke, oil,
petrol, gas, etc.
WHAT IS CARBON MONOXIDE
Carbon Monoxide (CO) is a highly poisonous gas which is released
when fuels are burnt. It is invisible, has no smell and is therefore
very difficult to detect with the human senses. The first warning
symptoms that CO is present in the air are usually headaches and
nausea. Under normal operating conditions, in a room where fuel-
burning appliances are well maintained and correctly ventilated,
the amount of Carbon Monoxide released into the room by the
appliances is not dangerous. A dangerous quantity of Carbon
Monoxide can occur if one or more of the following conditions
exists:
1. An appliance is faulty or is badly maintained.
2. A flue is partially or totally blocked.
3. A room is not adequately ventilated.
CAREFULLY READ AND UNDERSTAND THE CONTENTS
OF THIS INSTRUCTION MANUAL BEFORE USING THE
ALARM. RETAIN THE MANUAL IN A SAFE PLACE FOR
FUTURE REFERENCE.
PAY PARTICULAR ATTENTION TO THE SAFETY
WARNINGS. PASS THE MANUAL ONTO ANY
SUBSEQUENT USERS OF THE ALARM.
WARNING
THIS Carbon Monoxide ALARM MAY NOT PROTECT
PEOPLE WHO ARE AT SPECIAL RISK FROM Carbon
Monoxide EXPOSURE BY REASON OF AGE, PREGNANCY
OR MEDICAL CONDITION. IF IN DOUBT, CONSULT YOUR
MEDICAL PRACTITIONER.
This Carbon Monoxide Alarm is NOT:
•
A substitute for either a smoke alarm or a combustible
gas detector.
•
To be seen as a substitute for the proper servicing of
fuel-burning appliances or the sweeping of chimneys
•
To be used on an intermittent basis, or as a portable detector
for the spillage of combustion products from fuel-burning
appliances or chimneys.
CAUTION
This Carbon Monoxide alarm is designed for indoor use only.
Do not expose to rain or moisture. Do not knock or drop
the unit. Do not open or tamper with the unit as this
could cause malfunction.
The alarm will not protect against the risk of Carbon
Monoxide poisoning when the battery has drained.
IMPORTANT
•
Carbon Monoxide is produced by the incomplete combustion
of fuels such as wood, charcoal, coal, heating oil, paraffin,
petrol, natural gas, propane, butane etc.
•
Ideally, it is recommended that a Carbon Monoxide alarm
should be installed in or near to every room that has a fuel
Gas inlet
burning appliance such as any gas fires, central heating boiler,
room heaters, water heaters, cookers, grills, etc.
•
This alarm should only be installed by a competent person.
•
Ensure that the audible alarm can be heard by all those who
are intended to hear it.
•
This product should not be used if any fault signals are given.
•
Seek medical help if it is suspected that a member of the
household is suffering from Carbon Monoxide poisoning.
•
If further details are required which do not appear in this
manual, contact Honeywell Analytics.
This pack contains:
One unit
One fixing kit
One instruction manual
EFFECTS OF CARBON MONOXIDE POISONING
Carbon Monoxide binds to the haemoglobin in the blood and
reduces the amount of oxygen being circulated in the body.
200ppm
Slight headaches, tiredness, dizziness, nausea after
2-3 hours.
400ppm
Frontal headache within 1-2 hours, life threatening
after 3 hours.
800ppm
Dizziness, nausea and convulsions within 45 minutes.
Unconsciousness with 2 hours. Death within 2-3
hours.
1600ppm
Headache, dizziness and nausea within 20 minutes.
Death within 1 hour.
6400ppm
Headache, dizziness and nausea within 1-2 minutes.
Death within 10-15 minutes.
POSITIONING THE ALARM
1. Units located in the same room as a fuel-burning
appliance
•
If the unit is located on the wall it should be located at a height
greater than the height of any door or window but at least
150mm from the ceiling. If the unit is mounted on the ceiling it
should be at least 300mm from any wall.
•
The unit should be at a distance of between 1m and 3m from
the potential source.
•
If there is a partition in a room, the unit should be located on
the same side of the partition as the potential source.
•
In rooms with sloped ceilings, the unit should be located at the
high side of the room.
2. Units located in sleeping rooms and in rooms remote from
a fuel burning appliance
•
Units should be located relatively close to the breathing area
of the occupants.
WHERE NOT TO PUT THE ALARM
Do not place the unit in the following areas:
•
Outside the building.
•
In or below a cupboard.
•
In a damp or humid area.
•
Directly above a sink or cooker.
•
Next to a door or window or anywhere that would be affected
draughts, eg, extractor fan or air vent.
•
Where the air flow to the unit would be obstructed by curtains
or furniture.
•
Where dirt or dust could collect and block the sensor, and stop
it working.
•
In an area where the temperature could drop below -10˚C or
rise to above 40˚C.
•
Where it could be easily knocked, damaged, or where it could
be inadvertently removed.
IN WHICH ROOM TO PUT THE ALARM
Ideally, an alarm should be fitted in every room that contains a fuel-
burning appliance. However, if there is more than one appliance
and the number of units is limited, the following points should be
taken into consideration when deciding on the best location:
•
If there is an appliance in a room where people sleep, a unit
should be placed in that room.
•
A unit should be located in a room containing a flueless or
open-flued appliance.
•
If there is an appliance in a room which people use a lot, such
as a sitting room, a unit should be placed in that room.
•
In a bedsit, the unit should be placed as far away from the
cooking appliance as possible but near to where the person
sleeps.
•
If the appliance is in a room not normally used, such as a boiler
room, the unit should be placed just outside the room so that
the alarm will be heard more easily.
INSTALLING THE ALARM
The unit can either be free-standing or wall mounted, using the
fixings provided.
WALL MOUNTING INSTALLATION
Find a position to install the unit (see"where to put the alarm" and
"where not to put the alarm").
mounting pad
Option 1 Special Mounting Pad with
Fixing Pin (supplied)
Place the fixing pin through the
mounting pad. Using a hammer,
gently knock the fixing pin into the wall
fixing pin
wall
ensuring that the mounting pad is not
wall plug
hammered too firmly into the wall.
5mm
Option 2 Screw and wall plug
(NOT supplied)
If the wall is too hard to use the fixing
screw
pin, use a No. 4 round head screw and
wall
wall plug.
Once activated and tested (see "using the alarm"), the unit can
be hung on the protruding fixing pin using one of the 'keyholes'
indicated on the back of the unit by the lines shown.
USING THE ALARM
To activate the unit, pull out the activation strip at the base of the
unit. The green and red lights will flash briefly and the buzzer will
sound a short chirp.
Press the test button and hold for up to 5 seconds and check that
the red light flashes and the buzzer sounds.
The unit is now operating and is ready for use.
P
U
L
L
O
U
T
S
T
R
P I