INSTALLATION
AND SERVICE
MUST BE PERFORMED
BYA QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S
USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
Clearances
and Dimensions
1.
Provide adequate clearances between the range and adjacent combustible surfaces.
2.
Location--Check
location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3.
Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
F.ON
30÷
..................
Minimum to
wall on either
1"41
to
side of range
above 36" height.
/ iiiiiiii
i
_® _
®®)18
eitherside
I
/
of range.
SIDE
VIEW
I_13"_'1
Maximum
depth
r-
for cabinets
[F
above range top.
Fig. 1
_
30-1/8"
_
0'clearancebelowcooldngl_pandatrearofrange.
RANGE
OVERALL
DIMENSIONS
with door handle
T
Fig. 2
253/4'*
445_"
Door Open
,,'_"_
\
29 7/8
_- _-
Centerline
of range
I
.i
i
2-5/8" for models equipped
with warmer drawers"
3-1/2" for models equipped
with storage drawers
Fig. 3
Wall
Edge
*30"MiNiMUM CLEARANCE BETWEEN THETOP OFTHE COOKING SURFACEANDTHE
BOTTOM OF AN UN PROTECTED
WOOD OR METAL CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET iS PROTECTED BY NOT
LESS THAN 1/4" FLAM E RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SH EET STEEL, 0.015"
STAINLESS STEEL, 0.024" ALUMINUM OR 0.020" COPPER. 0" CLEARANCE IS THE MINIMUM FOR THE REAR OF THE
RANGE. FOLLOWALL DIMENSION REQUIREMENTS PROVIDEDABOVETO
PREVENT PROPERTY DAMAGE, POTENTIAL
FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE
SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED,
TH E RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJ ECTS HORIZONTALLY
A MINIMU M OF 5"
BEYOND THE BOTTOM OF THE CABINETS.