Determining a Physical Location
The controller can be installed almost anywhere, but it is more secure and reliable if installed in a secure
equipment room or wiring closet.
For maximum reliability, mount the controller using the following constraints:
•
•
•
•
•
Note
Class 1 laser product. Statement 1008
Warning
Waarschuwing
Klasse-1 laser produkt.
Varoitus
Luokan 1 lasertuote.
Attention
Produit laser de classe 1.
Warnung
Laserprodukt der Klasse 1.
Avvertenza
Prodotto laser di Classe 1.
Advarsel
Laserprodukt av klasse 1.
Aviso
Produto laser de classe 1.
¡Advertencia!
Producto láser Clase I.
78-17155-01
802.11a network enabled or disabled?
802.11g network enabled or disabled?
Radio Resource Management (RRM) (Auto-RF) enabled or disabled?
Be sure you can reach the controller and all cables.
Be sure that water or excessive moisture cannot get into the controller.
Ensure that airflow through the controller is not obstructed. Leave at least 4 inches clear on both
sides of the controller chassis.
Verify that the ambient temperature remains between 0 to 40˚ C (32 to 104˚ F).
Be sure that the controller is within one of the following distances of equipment connected to the
optional 1000BASE-SX port:
220 m (722 ft.) when using 160 MHz-km rated 62.5/125 m multimode f i ber.
–
275 m (902 ft.) when using 200 MHz-km rated 62.5/125 m multimode f i ber.
–
–
400 m (1312 ft.) when using 400 MHz-km rated 50/125 m multimode f i ber.
–
500 m (1641 ft.) when using 500 MHz-km rated 50/125 m multimode f i ber.
Each 1000BASE-SX connector provide 100/1000 Mbps wired connections to a network through
850nM (SX) fiber-optic links using LC physical connectors.