The client PC IP address is now displayed. In this example, we have assumed
IP address 10.11.12.13.
3. Type route add 192.168.100.0 mask 255.255.255.0 10.11.12.13 and press the
Enter key.
The ensuing network route ensures device accessibility.
Note that you should enter your own client PC IP address instead of
10.11.12.13.
4. Check that there is communication with the device by typing ping
192.168.100.100.
5. You must now allocate the desired IP address to the device via the device's
homepage. See section 10.1 Changing the device IP
Establishing initial communication with the device
address.