hit counter script
Table of Contents

Advertisement

Selector
No.
1
Maximum OGM recording time
2
3
Time length from CML ON to
start of pseud ring backtone
4
transmission
Attenuator for playback of ICM/
5
OGM to the line
|
(Selectable from the range of
8
0-15 dB)
Selectors 1 and 2: Maximum OGM recording time (For those models equipped with a built-in
TAD)
These selectors set the allowable maximum recording time for an OGM.
Selectors 3 and 4: Time length from CML ON to start of pseud ring backtone transmission
These selectors set the time length after CML becomes ON until the start of pseud ring
backtone transmission.
In those versions which have an OGM facility instead of pseud ring backtone, these selec-
tors set the time length after CML becomes ON until the start of OGM transmission.
Selectors 5 through 8:
Setting two or more selectors to "1" produces addition of attenuation assigned to each selec-
tor.
This setting will not be limited by selector 8 of WSW23.
WSW24
(TAD setting 2)
Function
Attenuator for playback of ICM/OGM to the line (For those models
equipped with a built-in TAD)
V – 54
Setting and Specifications
No. 1
2
0
0
:
15 sec.
0
1
:
20 sec.
1
0
:
30 sec.
1
1
:
50 sec.
No. 3
4
0
0
:
4 sec.
0
1
:
3 sec.
1
0
:
2 sec.
1
1
:
1 sec.
0: 0 dB
1: 8 dB
0: 0 dB
1: 4 dB
0: 0 dB
1: 2 dB
0: 0 dB
1: 1 dB