HP DDS-2 Tape Drive
User's Guide
Workstation Systems Group
Order No. A1658–90701
Edition E1296
Printed in U.S.A.

Advertisement

Table of Contents
loading

Summary of Contents for HP Model 705 - Workstation

  • Page 1 HP DDS-2 Tape Drive User’s Guide Workstation Systems Group Order No. A1658–90701 Edition E1296 Printed in U.S.A.
  • Page 2 Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard.
  • Page 3: Table Of Contents

    Contents Preface Audience ............. . Safety and Regulatory Statements .
  • Page 4 Contents Chapter 2 Using Your DDS Drive Your DDS-2 Drive Configuration ......... . 2–2 Controls and Features of the DDS-2 Drive .
  • Page 5 Contents Figures 1–1. HP DDS-2 Drive ........... 1–2 1–2.
  • Page 6: Preface

    Preface The HP DDS-2 Tape Drive User’s Guide describes how to install, configure, and use the HP DDS-2 tape drive. We’ve organized this guide as follows: Chapter 1 Provides a general description of the drive and the procedures for installing it into a system. Chapter 2 Describes the drive configurations, the controls and features of the drive, and provides directions for using it.
  • Page 7: Safety And Regulatory Statements

    Hewlett-Packard’s system certification tests were conducted with HP-supported peripheral devices and HP shielded cables, such as those you receive with your computer. Changes or modifications not expressly approved by Hewlett-Packard could void the user’s authority to operate the equipment. Operation of this device is subject to the following conditions: This device may not cause harmful interference.
  • Page 8 Preface Emissions Regulations Compliance Any third-party I/O device installed in HP system(s) must be in accordance with the requirements set forth in the preceding Emissions Regulations statements. In the event that a third-party noncompliant I/O device is installed, the customer assumes all responsibility and liability arising therefrom.
  • Page 9: Installation Notice

    Preface Installation Notice Products designated in the applicable Hewlett-Packard price list as customer-installable can be installed by computer-knowledgeable customers who carefully read and follow the instructions provided. Customers who elect to have the product installed by our field personnel are charged the applicable field installation charge, as covered under the standard terms and conditions.
  • Page 10: Questions And Problems

    Preface Questions, Suggestions, and Problems If you have any questions, suggestions, or problems with our hardware, software, or documentation, please call 1-888-301-5932 (toll free in U.S.A. and Canada), or contact your HP Response Center for your country. Documentation Conventions Unless otherwise noted in the text, this guide uses the following symbolic conventions: literal values Bold words or characters in formats and command descriptions represent commands that you must use literally.
  • Page 11: Chapter 1 Introduction

    Chapter 1 Introduction This document describes the HP DDS-2 (HP model number C1539A) drive, its installation, operation, troubleshooting, and removal/replacement procedures. This chapter introduces the DDS-2 drive and contains the following information: General description of the drive Major features of the drive Preparing to install the drive Preparing the system Powering off the workstation and any peripherals.
  • Page 12: General Description

    Introduction General Description The HP DDS-format drives have been developed by Hewlett Packard for data storage drives that build on DAT technology. The DDS-2 drive has 4-GB native capacity, yielding up to 8 GB of stored data and has data compression functionality. Figure 1–1 shows the DDS-2 drive.
  • Page 13: Major Features Of Dds Drives

    Introduction Major Features of DDS Drives The DDS-1 format incorporates error correction techniques used in audio DAT drives with additional techniques specifically designed to provide the integrity of data necessary for computer use. These extra methods of error detection and correction are as follows: C3 ECC, a third level of Error Correction Code providing correction across frames within groups.
  • Page 14 Introduction DDS-2 Drive The HP C1539A implements the DDS-2 format. This includes all of the features of the DDS-1 and DDS-DC formats, plus the ability to read and write with much higher capacity as follows: Reads and writes using DDS-1 and DDS-DC formats when using DDS-1 media (60 m and 90 m).
  • Page 15: Dds-2 Drive

    Introduction DDS-2 Drive Physical Specifications The following illustration describes the physical specifications of the DDS-2 drive. 41.3 mm +/– 0.6 60 mm 4 mm +/– 0.2 21 mm 5 mm 90 mm +/– 0.3 +/– 0.2 +/– 0.2 41.3 mm +/–...
  • Page 16: Preparing To Install The Dds-2 Drive

    Introduction Preparing to Install the DDS-2 Drive The following information describes how to prepare the DDS-2 drive for installation. Tools Required The following tools are needed to install the DDS-2 drive: #2 Phillips screwdriver Small needle-nose pliers T10 torx wrench Verifying Kit Contents Verify that the kit contains one of each of the following: DDS-2 drive (manufacturing part number 0950–2658)
  • Page 17: Setting The Scsi-2 Address

    Introduction Setting the SCSI-2 Address The DDS-2 drive must have a unique SCSI-2 target address. The DDS-2 drive’s jumpers are set at the factory to the SCSI-2 default address of 3 as shown in Figure 1–3. You must also ensure that the Operation Mode jumpers are set for correct drive operation, as shown in Figure 1–4.
  • Page 18: Address Jumpers

    Introduction If you need to change the Operation Mode switches, locate the switches on the un- derside of the DDS-2 tape drive. Switches 1 and 2 are used to configure the data compression operation mode. Switches 3 through 8 are used to specify drive connec- tivity and functionality according to host or customer requirements.
  • Page 19: Rear View Of Dds-2 Drive And Scsi Address/Jumper Settings

    Introduction Bit 0 Bit1 Bit 2 Term SCSI Connector Power Connector SCSI Term SCSI Term PWR* Bit 2 PWR* Bit 1 Bit 0 Bit 2 Bit 1 Bit 0 (Default) *Term PWR is not used in HP workstation configurations. Figure 1–3. Rear View of DDS-2 Drive and SCSI Address/Jumper Settings 1–9...
  • Page 20: Switch Settings For Data Compression Operation Mode

    Introduction Figure 1–4. Switch Settings for Data Compression Operation Mode 1–10...
  • Page 21: Preparing The System

    Introduction Preparing the System Perform the following steps to prepare the system for the DDS-2 drive installation: Determine the existing SCSI-2 address settings currently in use on your system by completing the following steps:. If you are using HP-UX 9.X, enter the following at the prompt: /etc/ioscan -d scsitape RETURN If you are using HP-UX 10.X, enter the following at the prompt:...
  • Page 22 Introduction H/W Path Class Description ========================================== I/O Adapter ext_bus GSC built-in Fast/Wide SCSI Interface 8/0.0 target 8/0.0.0 disk QUANTUM LPS1080WD 8/0.5 target 8/0.5.0 disk DEC DSP3210SW 8/0.6 target 8/0.6.0 disk DEC DSP3210SW 8/12 Core I/O Adapter 8/12/5 ext_bus Built-in SCSI 8/12/5.3 target 8/12/5.3.0...
  • Page 23: Scsi-2 Connection And Termination

    Introduction You must have superuser privileges to use the /etc/shutdown command. If you do not have superuser privileges, contact your system administrator. If your workstation is part of a cluster, refer to Managing Clusters of HP 9000 Com- puters for instructions on shutting down. SCSI-2 Connection and Termination Only single-ended SCSI-2 configuration is supported, with a maximum sustained transfer rate of 5.0 MB/second.
  • Page 24: Powering Off The Workstation And Any Peripherals

    Introduction Powering Off the Workstation and any Peripherals To power off the workstation and any peripherals, perform the following steps: Power off the workstation, using the power switch on the front of the workstation. CAUTION: Do not power off your workstation without first shutting down HP-UX.
  • Page 25: Adding Or Removing The Dds-2 Drive Bezels Or Expansion Brackets

    Introduction Adding or Removing the DDS-2 Drive Bezels or Expansion Brackets Depending on the size of the drive opening in your system, you may need to add or remove a bezel or expansion brackets to ensure that your DDS-2 drive fits in your system.
  • Page 26: Removing A Bezel From The Dds-2 Drive

    Introduction To remove a bezel from a drive, use a straight blade screwdriver to lift the bezel tabs from the sides of the drive. Refer to Figure 1–6. Figure 1–6. Removing a Bezel from the DDS-2 Drive To add expansion brackets to the drive or to remove them, use a T10 torx wrench to either tighten or remove the four torx screws that hold each expansion bracket to the drive.
  • Page 27 Introduction You are now ready to begin the hardware installation of your DDS-2 drive. The step-by-step instructions for installing the drive are found in the Owner’s Guide that came with your workstation. 1–17...
  • Page 28 Chapter 2 Using the DDS-2 Drive This chapter provides the following information on using your DDS-2 drive: DDS-2 drive configuration Controls and features of the DDS-2 drive Using the DDS-2 drive To verify HP-UX system operation, see the Owner’s Guide that came with your workstation.
  • Page 29: Chapter 2 Using Your Dds Drive

    Using Your DDS Drive Your DDS-2 Drive Configuration Your HP-UX operating system comes with preconfigured device files and drivers. If you use these preconfigured device files and drivers, you won’t need to configure your DDS-2 drive with the operating system. To find out more about creating and using device files, the the Owner’s Guide that came with your system.
  • Page 30: Leds

    Using Your DDS Drive LEDs The front panel has two colored LEDs: the Tape Light and the Clean/Attention Light. The Tape Light flashes green to show activity (loading, unloading, reading, and writing). Steady green means a cartridge is loaded. The Clean/Attention Light flashes amber to indicate head cleaning is needed or a cartridge is near the end of its life.
  • Page 31: Cleaning The Tape Heads

    Using Your DDS Drive The relative humidity in your operating environment is consistently less than 50%. You know that the backup software you are using makes multiple passes over sections of the tape during backups or restores. You notice that when you do backups and restores the tape stops and starts fre- quently.
  • Page 32: Setting The Write-Protect Tab On A Dds Tape

    Using Your DDS Drive Figure 2–2. Setting the Write-Protect Tab on a DDS Tape To protect information on a data cassette from being overwritten, set the write-protect tab to the write-protect position, as shown in Figure 2–2. NOTICE: The write-protect tab should always be in the write position for transferring data to a cassette.
  • Page 33: Using The Dds-2 Drive

    Using Your DDS Drive Using the DDS-2 Drive This section describes how to perform tasks with your DDS-2 tape drive. Loading and Unloading a Data Cassette Follow these steps to load and unload a data cassette from the DDS-2 tape drive: Turn on power to the tape drive.
  • Page 34: Verifying The Dds-2 Tape Drive Operation

    Using Your DDS Drive Push the data cassette about three quarters of the way into the drive. The drive automatically pulls the data cassette the rest of the way in. When the LEDs on the front of the drive stop flashing, the drive has loaded the data cassette. To remove the data cassette, press and release the eject button on the front of the drive, as shown in Figure 2–3.
  • Page 35: Media Interchangeability Restrictions

    Using Your DDS Drive For information on using device files or archiving data to or from the DDS-2 drive, see the Owner’s Guide that came with your workstation. Media Interchangeability Restrictions If you interchange media between DDS-format tape drives, note that data cassettes with compressed data can only be read by tape drives that have data compression capabilities.
  • Page 36: Ordering Information

    Using Your DDS Drive Ordering Information To order Hewlett-Packard data cassettes and cleaning cassettes for use in your DDS-2 tape drive, use the following order numbers: HP92283A Box of five 60-meter DDS data cassettes HP92283B Box of five 90-meter DDS data cassettes...
  • Page 37: Chapter 3 Troubleshooting And Removal/Replacement Procedures

    Chapter 3 Troubleshooting and Removal/Replacement Procedures This chapter provides the following information on troubleshooting and removal/replacement procedures for your DDS-2 drive: Checking the address settings Checking the hardware installation Verifying system operation Field Replaceable Units Powering off the system Removing and replacing the DDS-2 drive Adding or removing DDS-2 drive bezels and expansion brackets 3–1...
  • Page 38: Troubleshooting

    Troubleshooting and Removal/Replacement Procedures Troubleshooting If you have trouble with any of these procedures, see the Owner’s Guide that came with your system. This chapter explains what to do if you experience problems during the configuration process. It also explains how to run the Support Tool Manager or the Extended Self Test to verify your system.
  • Page 39 Troubleshooting and Removal/Replacement Procedures A screen similar to the following appears: H/W Path Description Status ==================================== 1.0.0 graphics ok(0x577) 2.0.1 scsi ok(0x7071) 2.0.1.3.0 tape_drive ok(0x1800202) 2.0.2 ok(0x7072) 2.0.3 ok(0x7073) 2.0.4 serial ok(0x7075) 2.0.5 serial ok(0x7075) 2.0.6 parallel ok(0x7074) 2.0.7 scsi ok(0x707c) 2.0.7.6.0 disk...
  • Page 40: Checking The Hardware Installation

    Troubleshooting and Removal/Replacement Procedures H/W Path Class Description ============================================ I/O Adapter ext_bus GSC built-in Fast/Wide SCSI Interface 8/0.0 target 8/0.0.0 disk QUANTUM LPS1080WD 8/0.5 target 8/0.5.0 disk DSP3210SW 8/0.6 target 8/0.6.0 disk DSP3210SW 8/12 Core I/O Adapter 8/12/5 ext_bus Built-in SCSI 8/12/5.3 target 8/12/5.3.0...
  • Page 41 Troubleshooting and Removal/Replacement Procedures Attach the static-grounding wrist strap by following the instructions on the package that contains the strap. Shut down HP-UX. NOTICE: If you are already at the boot administration level, you do not need to shut down; skip this step and go on to Step 4. If you are running HP-UX under HP VUE, shut down your system by performing the shutdown procedure described in the Owner’s Guide that came with your work- station.
  • Page 42: Rechecking The Address Settings

    Troubleshooting and Removal/Replacement Procedures Recheck the device list (see “Recheck the Address Settings” below). Rechecking the Address Settings Check the address settings again to see if the drive is now listed (see “Checking the Address Settings for Single-Ended Drives,” earlier in this chapter). If the DDS-2 drive and all other SCSI-2 devices available to you before you installed the DDS-2 drive are now listed, run the system verification test for your software version, as explained in the next sections.
  • Page 43 Troubleshooting and Removal/Replacement Procedures To access the Support Tools Manager, perform the following steps: Click on the Terminal Control on the Front Panel of your Workspace. Terminal Control A terminal window opens. Move the mouse cursor into the terminal window and click the left mouse button. Enter the following at the prompt: cstm RETURN...
  • Page 44 Troubleshooting and Removal/Replacement Procedures To verify the system operation, type the following at the prompt: CSTM> CSTM> verify all RETURN Messages similar to the following appear: Verification has started on device (CPU). Verification has started on device (FPU). CSTM>Verification of (FPU) has completed. CSTM>Verification of (CPU) has completed.
  • Page 45: Removal/Replacement Procedures

    Troubleshooting and Removal/Replacement Procedures Removal/Replacement Procedures The removal/replacement procedures for the DDS-2 drive follow. CAUTION: Electrostatic charges can damage the integrated circuits on printed circuit boards. To prevent such damage from occurring, follow proper ESD precautions. Field Replaceable Units The following components are authorized for field replacement. Description Part Number DDS-2, Repalcement...
  • Page 46: Removing And Replacing The Dds-2 Drive

    Troubleshooting and Removal/Replacement Procedures Removing and Replacing the DDS-2 Drive To open your system, remove and reinstall the DDS-2 drive, refer to the Owner’s Guide that came with your system. Read “Preparing to Install the DDS-2 Drive” in Chapter 1 of this guide before beginning an installation.
  • Page 47: Adding A Bezel To The Dds-2 Drive

    Troubleshooting and Removal/Replacement Procedures Figure 3–1. Adding a Bezel to the DDS-2 Drive Figure 3–2. Removing a Bezel from the DDS-2 Drive 3–11...
  • Page 48: Adding Or Removing Expansion Brackets

    Troubleshooting and Removal/Replacement Procedures Figure 3–3. Adding or Removing Expansion Brackets 3–12...
  • Page 49: Appendix A Scsi Connector Pinnouts

    Appendix A SCSI Connector Pinouts Table A–1. SCSI Connector Pinouts SIGNAL SIGNAL TERMPWR DB(0) DB(1) DB(2) –ATN DB(3) DB(4) –BSY DB(5) –ACK DB(6) –RST DB(7) –MSG DB(P) –SEL –C/D –REQ OPEN –I/O A–1...
  • Page 50 Index DDS–format tape drive, write–protecting a data cassette, 2–4– 2–9 bezels, adding or removing, 1–15, 3–10 electrostatic discharge precautions, ix CD–ROM disc, caring for, 3–2 emissions regulations, viii–xi CD–ROM drive emissions regulations compliance, ix controls and features, 2–2 exit command, SupportWave, 3–8 troubleshooting, 3–2–3–12 using, 2–6 commands...
  • Page 51 safety and regulatory statements, viii ordering information, DDS–format tape SCSI IDs, jumpers, DDS drive, 1–9 cassettes, 2–9 troubleshooting, CD–ROM drive, 3–2–3–12 regulatory statements emissions regulations compliance, ESD precautions, ix verify command, 3–8 Index-2...
  • Page 52 HP DDS-2 Tape Drive User’s Guide Workstation Systems Group Order No. A1658–90701 Edition E1296 Printed in U.S.A.
  • Page 53 Order Number: A1658–90701 Edition E1296 Printed in U.S.A.

Table of Contents