hit counter script
IBM 7316 - TF1 Rack Console Installation And Maintenance Manual
IBM 7316 - TF1 Rack Console Installation And Maintenance Manual

IBM 7316 - TF1 Rack Console Installation And Maintenance Manual

17-inch flat panel rack-mounted monitor and keyboard

Advertisement

ERserver
7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard
Installation and Maintenance Guide
SA38-0643-00

Advertisement

Table of Contents
loading

Summary of Contents for IBM 7316 - TF1 Rack Console

  • Page 1 ERserver 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard Installation and Maintenance Guide SA38-0643-00...
  • Page 3 ERserver 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard Installation and Maintenance Guide SA38-0643-00...
  • Page 4 A reader’s comment form is provided at the back of this publication. If the form has been removed, address comments to Information Development, Department H6DS-905-6C006, 11501 Burnet Road, Austin, Texas 78758-3493. To send comments electronically, use this commercial internet address: aix6kpub@austin.ibm.com. Any information that you supply may be used without incurring any obligation to you.
  • Page 5: Table Of Contents

    Contents Safety Notices........v Rack Safety Instructions ......v Relocating the Rack .
  • Page 6 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 7: Safety Notices

    Safety Notices A danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury. A caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury. Note: For a translation of these notices, see System Unit Safety Information, order number G229-9054-00.
  • Page 8: Relocating The Rack

    Relocating the Rack When relocating the rack, make sure you follow these guidelines: CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building: v Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack cabinet.
  • Page 9 DANGER Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. Ensure outlet supplies proper voltage and phase rotation according to the system rating plate.
  • Page 10 viii 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 11: Data Integrity And Verification

    Data Integrity and Verification IBM computer systems contain mechanisms designed to reduce the possibility of undetected data corruption or loss. This risk, however, cannot be eliminated. Users who experience unplanned outages, system failures, power fluctuations or outages, or component failures must verify the accuracy of operations performed and data saved or transmitted by the system at or near the time of the outage or failure.
  • Page 12 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 13: About This Book

    About This Book ® This book provides information on how to install the IBM 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard. References to AIX Operating System This document may contain references to the AIX operating system. If you are using another operating system, consult the appropriate documentation for that operating system.
  • Page 14 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 15: Chapter 1. Introduction

    Chapter 1. Introduction The IBM Eserver 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard is a flat-panel monitor and keyboard tray. A special keyboard, available for a variety of languages, fits inside the front of the keyboard tray. The monitor and keyboard tray occupy 1 EIA (Electronics Industries Association) unit of space in a rack cabinet.
  • Page 16 h One 1.8 m (6 ft) power cord h One 2.4-m (8-ft) IEC connector power cable h One thin keyboard with built-in pointing device h Keyboard extension cable h Mouse extension cable h One CD containing Windows keyboard and mouse drivers (not for use with Eserver pSeries systems or any AIX, Linux, or OS/400-based system) h Monitor and keyboard documentation (including this...
  • Page 17: Chapter 2. Installing The 7316-Tf3 17-Inch Flat Panel Rack-Mounted Monitor And Keyboard

    Chapter 2. Installing the 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard The IBM 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard occupies 1.75 inches (1 EIA) of rack-mounting space in a rack cabinet. You can use the brackets that are provided with this kit to install an optional console switch in the same rack-mounting space as the monitor console kit.
  • Page 18: Installing The Monitor And Keyboard Tray Into A Rack

    Installing the Monitor and Keyboard Tray into a Rack Removing rack doors and side panels might make installation easier. For additional information about removing the doors, refer to the documentation that was provided with your rack cabinet. To install the tray into the rack: 1.
  • Page 19 3. Loosen the two rail-adjustment screws on each of the outer slide rails. Then, extend the rails to their maximum outward adjustment. Rail-adjustment screws 4. Adjust the outer slide-rail brackets to fit the depth of the rack cabinet. Then, loosely attach the front of the slide-rail brackets to fit the depth of the rack cabinet using four screws from the miscellaneous hardware kit.
  • Page 20 rack-cabinet mounting flanges. 6. Tighten the two rail-adjustment screws on each of the outer rails that you loosened in step 3 on page 7. Insert the rail-alignment spacer into the slide-rail middle holes. The rail-alignment spacer must wrap around the rails (top and bottom of the front of the rail) to align them correctly. Tighten the front four screws;...
  • Page 21 9. Carefully slide the flat-panel monitor and keyboard tray into the ball-bearing assemblies in the rails. 10. Press the release latches and push the flat-panel monitor and keyboard tray completely into the rack. There will be resistance initially as the ball-bearing assemblies align between the inner and outer rails.
  • Page 22 13. Pull the tray out of the rack until it is extended fully on the rails. 14. Carefully lift the front of the flat-panel monitor, then raise the monitor to the full upright position. 15. Carefully insert the keyboard into the tray. Then, route the keyboard-and-mouse cable through the cord clip on the bottom of the tray, up through the opening on the right side of the tray, and toward the cable-management arm.
  • Page 23 20. Still from the rear of the rack, remove the rail-adjustment screw closest to the back of the rack from the left-slide rail. Attach the cable-management arm to the rail using this screw. 21. Connect the video, keyboard, and mouse connectors to either a server or optional console switch in the rack cabinet.
  • Page 24: Installing The Optional Console Switch

    Note: When the monitor and keyboard are not in use, if the rack cabinet is in a vibration-prone area, or during cabinet relocation, tighten the two thumbscrews on the front of the tray to secure the tray inside the rack cabinet. Thumbscrew Installing the Optional Console Switch Attention:...
  • Page 25 2. Install the console switch behind the flat-panel monitor and keyboard tray using four (two on each side) of the Phillips screws supplied in your miscellaneous hardware kit. 3. Route the power, video, and keyboard-and-mouse cables through the channel in the left-side bracket on the console switch.
  • Page 26 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 27: Chapter 3. Using The Monitor

    Place your LCD monitor in a location with low humidity and a minimum amount of dust. v If the LCD monitor accidentally gets wet, unplug it and contact your IBM representative or reseller immediately. You can clean the LCD monitor with a damp cloth when necessary, but be sure to unplug the LCD monitor first.
  • Page 28: Technical Specifications

    v Moves the selector left and right on the OSD menu v Increases or deceases the value of the selected adjustment or selects the proper setting v Adjusts the brightness of the back light lamp by pressing the t or u buttons without the OSD menu (Hot key) Menu v Opens the OSD menu...
  • Page 29: Chapter 4. Hardware Maintenance Information

    Chapter 4. Hardware Maintenance Information This chapter contains information about IBM customer-replaceable units (CRUs) for the 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard. Customer-Replaceable Unit Part Numbers Only two components of the 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard are customer replaceable: the entire kit itself (CRU part number 80P3750) and the thin keyboard with built-in pointing device.
  • Page 30 2. If you installed a console switch in the rear of the rack cabinet, remove the console switch from the rack. 3. Remove the screw that attaches the cable-management arm to the outer slide-rail bracket. 4. Fully extend the monitor and keyboard tray from the front of the rack cabinet. Push in the release latch on each side of the tray and slide the monitor and keyboard tray assembly out of the rack.
  • Page 31 6. Loosen the four rail-adjustment screws on both new outer slide-rail brackets and extend the brackets to their maximum outward adjustment. Rail-adjustment screws 7. Adjust the new outer slide-rail brackets to fit the depth of the rack cabinet. Attach the front of the new slide-rail brackets to the rack cabinet using four screws.
  • Page 32 8. Repeat the previous step for the rear of the slide-rail brackets. Again, make sure that the slide-rail brackets extend outside of the rack-cabinet mounting flanges. 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 33 9. Tighten the two rail-adjustment screws on each of the outer rails that you loosened in step 6 on page 10. Loosen the front four slide-rail bracket screws; then, insert the rail-alignment spacer into the slide-rail middle holes. The rail-alignment spacer must wrap around the rails to align them correctly. Tighten the front four screws and remove the spacer.
  • Page 34: Replacing The Keyboard

    Replacing the Keyboard To replace the keyboard, complete the following steps: 1. Place the keyboard on a stable flat surface and remove the two adhesive rubber pads from the bottom of the new keyboard. (If you leave the rubber pads on the keyboard, they will extend into the space below the tray.) Attention: Do not extend the keyboard feet.
  • Page 35 cable-management arm. Pull the full length of the cable through the opening. Keyboard-and-mouse cable routing 8. Secure the keyboard-and-mouse cable to the cable-management arm using the existing cable straps. 9. Reconnect the keyboard-and-mouse cable to the server or console switch. Chapter 4.
  • Page 36 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 37: Appendix A. Communications Statements

    Appendix A. Communications Statements The following statement applies to this product. The statement for other products intended for use with this product appears in their accompanying documentation. Federal Communications Commission (FCC) Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 38: European Union Emc Directive Conformance Statement

    European Union EMC Directive Conformance Statement This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. The manufacturer cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of option cards supplied by third parties.
  • Page 39: Radio Protection For Germany

    Dieses Gerät ist berechtigt in Übereinstimmung mit Dem deutschen EMVG vom 9.Nov.92 das EG–Konformitätszeichen zu führen. Der Aussteller der Konformitätserklärung ist die IBM Germany. Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse A. Für diese von Geräten gilt folgende Bestimmung nach dem EMVG: Geräte dürfen an Orten, für die sie nicht ausreichend entstört sind, nur mit besonderer Genehmigung des...
  • Page 40 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 41: Appendix B. Environmental Notices

    Before this unit is disposed of, these materials must be removed and recycled or discarded according to applicable regulations. IBM offers product-return programs in several countries. For country specific instructions refer to the following web site: http://www.ibm.com/ibm/environment/products/prp.phtml This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery.
  • Page 42 Dette produkt kan indeholde et f orseglet batteri, der indeholder b ly, nikkel-kadmium, nikk el-metal-hydrid, litium eller litium-ion. Der er flere oplysninger om batter iet i bruger- eller servicevejledningen. Batteriet må ikke kasseres sammen med det almindelige aff ald. Batteriet skal kasseres i henhold til de lokale bestemmelser . Spørg eventuelt kommunens teknisk e forvaltning (Miljø...
  • Page 43 Questo prodotto potrebbe contenere una batteria al piombo, al nichel-cadmio, all ’idruro di nichel, al litio o agli ioni di litio. Consultare il manuale utente o il manuale di assistenza per informazioni specifiche sulla batteria. La batteria deve essere appropriatamente riciclata o smaltita. Il servizio per il riciclaggio potrebbero non essere disponibile nella vostra zona.
  • Page 44 Produkten kan innehålla ett förseglat batteri av någon av typerna blyackumulator , nickel-kadmium, nickel-metallhydrid, litium eller litiumjon. Detaljerad batteriinformation finns I användar - eller servicehandboken. Batteriet måste lämnas till återvinning eller kastas på ett miljösäkert sätt. Det kanske inte finns några återvinningsmöjligheter där du bor . När det gäller omhändertagande av batterier ber vi att få...
  • Page 45: Environmental Design

    In the United States, IBM has established a collection process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and other battery packs from IBM Equipment. For information on proper disposal of these batteries, please contact IBM at 1-800-426-4333.
  • Page 46: Ergonomic Information

    The Healthy Computing Web site gives ergonomic guidelines to help you understand the ergonomic considerations that you should know when working at a computer workstation. The address is: http://www.us.pc.ibm.com/healthycomputing 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 47: Appendix C. Notices

    Appendix C. Notices This information was developed for products and services offered in the U.S.A. The manufacturer may not offer the products, services, or features discussed in this document in other countries. Consult the manufacturer’s representative for information on the products and services currently available in your area.
  • Page 48 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 49: Index

    Index recycling 27 replacing battery customer-replaceable unit (CRU) part numbers 15 disposal, recycling 27 inner slide rails 15 keyboard 20 outer slide rails 15 slide rails 15 console switch installing 10 rack preparation 4 customer-replaceable parts 15 safety v slide rails, replacing 15 specifications technical 14 ergonomic information 32...
  • Page 50 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard: Installation and Maintenance Guide...
  • Page 51 Thank you for your responses. May we contact you? h Yes h No When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you. Name...
  • Page 52 Readers’ Comments — We’d Like to Hear from You Cut or Fold Along Line SA38-0643-00 Fold and Tape Please do not staple Fold and Tape _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ NO POSTAGE NECESSARY IF MAILED IN THE...
  • Page 54 Part Number: 80P3752 Printed in USA May 2004 SA38-0643-00...

This manual is also suitable for:

Eserver 7316-tf3

Table of Contents