11-12. Presser foot installation position
11-13. Changing the intermittent stroke
The intermittent stroke can be adjusted to within 2 − 10 mm by adjusting the position of the stepping clamp connecting rod
and changing the installation position of stepping clamp link A.
<Changing the installation position of stepping clamp link A>
1. Remove the face plate.
2. Remove the two screws (1) and the two shoulder screws (2), and then remove stepping clamp link A (3).
3. Change the installation position for stepping clamp link A (3) to either A, B or C above.
If the position of the stepping clamp connecting rod is adjusted as described in the following at any one of the installation
positions, the adjustment range for the intermittent stroke will as given in the following table. (Refer to the next page.)
Installation position
A
B
C
1894B
2 − 4.5mm
4.5 − 10mm
0 mm (Presser foot does not move up and down)
BAS-342G PS
Install the intermittent presser foot (1) with the screw (2) so
that the distance from the bottom of the intermittent presser
foot to the top of the needle plate is 19.5 mm when the
sewing machine is stopped and the intermittent presser foot
(1) is raised.
Intermittent stroke range
11. STANDARD ADJUSTMENTS
4049M
5012Q