6. USING THE OPERATION PANEL (BASIC OPERATIONS)
6-6. Checking the sewing pattern
Use test feed mode to check the needle movement with only the work clamp operating.
Check that the needle hole in the needle plate does not come out from the frame of the work clamp.
1
TEST indicator illuminates
2
COUNTER indicator illuminates
3
Starting continuous test feed mode
TEST indicator illuminates
TEST indicator switches off
4
If test feeding continues until the
final stitch, the work clamp will move
to the sewing start position and then
stop.
TEST indicator switches off
31
Press the TEST key.
Select the program number to be checked, and then set the X-scale and
the Y-scale.
• The program number will flash.
Depress the work clamp switch (1) to lower the work clamp, and then
depress the start switch (2).
• The work clamp will move to the sewing start position, and then the
program number will stop flashing and illuminate steadily.
• The number of stitches will appear in the menu display.
Depress the work clamp switch (1) to lower the work clamp, and then
depress and release the start switch (2).
• The work clamp will start moving continuously one stitch at a time.
[Fast-forward test mode]
If the work clamp switch (1) is depressed while the work clamp is moving,
the feeding speed can be increased while the work clamp switch (1) is
depressed.
When the
forward by one stitch, and when the
pressed, the work clamp will move backward by one
stitch. (It will move quicker if you keep the key pressed
down.)
If you would like sewing to start while test feeding is in
progress, press the TEST key to switch off the TEST
indicator.
When the start switch (2) is depressed, sewing will
start.
Press the TEST key.
BAS-342G PS
key is pressed, the work clamp will move
4957Q 4014M
4014M
4443Q
key is
4014M