hit counter script
Philips HX7990/02 User Manual

Philips HX7990/02 User Manual

Uv brush head sanitizer
Hide thumbs Also See for HX7990/02:

Advertisement

UV Sanitizer
HX7990
4235.020.2467.3.indd 1
02-10-2007 14:07:16

Advertisement

Table of Contents
loading

Summary of Contents for Philips HX7990/02

  • Page 1 UV Sanitizer HX7990 4235.020.2467.3.indd 1 02-10-2007 14:07:16...
  • Page 2 Fig. 1 4235.020.2467.3.indd 2 02-10-2007 14:07:16...
  • Page 3 EnglisH 4 4235.020.2467.3.indd 3 02-10-2007 14:07:17...
  • Page 4 EnglisH introduction The Sonicare UV Sanitizer uses a specially designed UV light bulb that helps kill germs on the brush head of your rechargeable toothbrush in a 10-minute sanitizing cycle. When used properly on Sonicare ProResults, Sonicare e-series, Oral-B Flexisoft* and Oral-B FlossAction** brush heads, this device is designed and demonstrated to act upon the following germs: Streptococcus mutans, Herpes...
  • Page 5 EnglisH WARnings Toreducetheriskofburns,electricshock, fire or injury: 1 DO NOT plug into an outlet with a voltage other than specified on the bottom of the sanitizer. Voltage converters and plug adapters DO NOT guarantee voltage compatibility. Never force the plug into an outlet; if it does not easily fit into the outlet, discontinue use.
  • Page 6: GeneralDescription(Fig.1)

    EnglisH 8 Do not use attachments other than those recommended by the manufacturer. 9 Do not use if dropped into water. 10 Do not use this product or any of its components for purposes other than described in this manual. 11 Do not operate the UV sanitizer where aerosol (spray) products are being used or where oxygen is being administered.
  • Page 7: Before First Use

    Do not crush or break the bulb. UV light bulbs contain a small amount of mercury. Note: Use only the UV light bulb supplied or a replacement UV light bulb ordered from Philips or Philips Authorized Service Centers. Note: To remove the UV light bulb, pull it out of the lamp holder. Align the pegs on the protective screen with the slots in the reflective surface of the sanitizer on either side of the UV light bulb.
  • Page 8 EnglisH Insert and gently push down the screen to secure it in the sanitizer. Reattach the drip tray. Preparingforuse sanitizingsonicaree-seriesbrushheads Place your finger in the door recess on the right-hand side of the sanitizer and pull open the door. Place the brush heads directly on the drip tray with the bristles facing the UV light bulb. sanitizingsonicareProResults,Oral-B FlexisoftandOral-BFlossActionbrush heads Note: This sanitizer is NOT suitable for other brush heads. Place your finger in the door recess on the right-hand side of the sanitizer and pull open the door. Remove the drip tray. Select the appropriate brush head holder (see chapter ‘General description’). 4235.020.2467.3.indd 8 02-10-2007 14:07:22...
  • Page 9 EnglisH Attach the brush head onto the appropriate brush head holder (see chapter ‘General description’). Attach the left brush head holder (L) to the left side of the center post until it clicks into place. Note: The brush head holders do not fit properly when you place the right brush head holder first. Always start with the left brush head holder. Attach the right brush head holder (R) to the right side of the center post until it clicks into place. Place the drip tray back into the sanitizer. Place the brush heads onto the brush head holders with the bristles pointing towards the UV light bulb. Sanitizing brush heads of two different types If you want to sanitize brush heads of two different types, use the appropriate brush head holder for...
  • Page 10 EnglisH Usingtheappliance Do not place the travel cap on the brush head during sanitization. After brushing, rinse the brush head and shake off excess water. Place your finger in the door recess on the right-hand side of the sanitizer and pull open the door. Put the brush heads into the sanitizer (see chapter ‘Preparing for use’). Note: Make sure the bristles of the brush head face the light bulb. Close the sanitizer door. Note: The sanitizer does not work when the door is not properly closed. Put the plug in a live power outlet. Press the power on/off button to start the UV clean cycle.
  • Page 11: Cleaning And Maintenance

    EnglisH Cleaningandmaintenance Do not clean any of the sanitizer accessories in a dishwasher. Do not clean the sanitizer when the UV light bulb is hot. For optimal effectiveness, it is recommended to clean your sanitizer as follows: Unplug the sanitizer. Remove the drip tray, protective screen and the light bulb (see chapter ‘Before first use’). Thoroughly rinse the brush head holders and the drip tray with warm soapy water and wipe them clean with a damp cloth. Wipe the bulb, the protective screen, and all internal and external surfaces with a damp cloth. Let all items dry before you reinstall them. Reattach the drip tray, protective screen and light bulb (see chapter ‘Before first use’). storage If you are not going to use the sanitizer for an extended period of time, unplug it from the electrical outlet, clean it and store it in a cool and dry place away from direct sunlight.
  • Page 12 EnglisH Replacement Replacement parts are available through your Sonicare Customer Service Center. Refer to the Guarantee and Service section of this manual for phone number and website information. The parts available for ordering are: UV light bulb Brush head holders Protective screen ReplacingtheUVlightbulb When the UV clean LED flashes quickly, the UV light...
  • Page 13: Warranty Exclusions

    ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. liMiTATiOnOFREMEDiEs IN NO EVENT SHALL PHILIPS OR ANY OF ITS AFFILIATED OR SUBSIDIARY COMPANIES BE LIABLE FOR ANY SPECIAL, INCIDENTAL 4235.020.2467.3.indd 13 02-10-2007 14:07:28...
  • Page 14: Troubleshooting

    EnglisH OR CONSEQUENTIAL DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, TORT, OR ANY OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE, WITHOUT LIMITATION, LOSS OF SAVINGS OR REVENUE; LOSS OF PROFIT; LOSS OF USE; THE CLAIMS OF THIRD PARTIES INCLUDING, WITHOUT LIMITATION, DENTISTS AND DENTAL HYGIENISTS;...
  • Page 15 EnglisH Problem Solution Make sure you use the correct brush head holder (see chapter ‘General description’). Make sure the bristles point towards the UV light bulb. The bristles of my Exposure to UV light may cause bristles to brush head change slightly change color over time.
  • Page 16 For support call 1-800-682-7664 © 2007 Philips Oral Healthcare, Inc. All rights reserved. PHILIPS and the Philips shield are registered trademarks of Koninklijke Philips Electronics NV. Elite, Sonicare and the Sonicare logo are trademarks of Philips Oral Healthcare, Inc.