Ductwork; Installation Instructions - GE PP989DNBB - Profile 30" Smoothtop Electric Downdraft Cooktop Use And Care Manual

Radiant downdraft cooktop
Hide thumbs Also See for PP989DNBB - Profile 30" Smoothtop Electric Downdraft Cooktop:
Table of Contents

Advertisement

Available languages

Available languages

Tools AND mATeRIAls
you WIll NeeD
• Saw
• Flat-blade screwdriver
• Electrician's pliers
• Duct tape
• Measuring tape or scale
• Carpenter's square
• 7/16≤ wrench or socket set
• Drill and drill bit
• Sheet metal screws
• Junction box*
• 3/4≤ flexible conduit*
• Electrical wire per local code*
• Wire nuts*

• Ductwork

* N oTe: Electrical installation kit JXCK89 may be
ordered separately and includes all the parts
necessary to connect the cooktop to typical
rough-in wiring .
CAuTIoN:
foR PeRsoNAl sAfeTy,
RemoVe house fuse oR CIRCuIT BReAkeR
BefoRe BeGINNING INsTAllATIoN.
30" CookToP (DImeNsIoNs foR RefeReNCe oNly)
Installation Instructions
PRePARATIoN
unit shown fully assembled.
22
"
7
16
(22
" SS)
9
16
20
"
1
2
unit must be vented to the outside!
15
eleCTRICAl RequIRemeNTs
This appliance must be supplied with the proper voltage
and frequency, as listed in these Installation Instructions,
and connected to an individual, properly grounded branch
circuit, protected by a 40-amp circuit breaker or time delay
fuses .
All wire connections must be made in accordance with
local codes and properly insulated . Check with your local
utility for governing electrical codes and ordinances . In the
absence of local electrical codes, the National Electrical
Code, ANSI/NFPA No . 70 – Latest Edition, governing electric
range installations, must be followed .
A copy of the National Electrical Code can be obtained by
writing to:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02260
Effective January 1, 1996, the National Electrical Code
requires that new, but not existing, construction utilize a
four-conductor connection to an electric range . When
installing an electric range in new construction, follow
the instructions in NEW CONSTRUCTION AND FOUR-
CONDUCTOR BRANCH CIRCUIT CONNECTION .
You must use a three-wire, single-phase AC 208Y/120 Volt
or 240/120 Volt, 60 Hertz electrical system with separate
ground . If you connect to aluminum wiring, properly
installed connectors approved for use with aluminum
wiring must be used
.
29
7
(30" SS)
22"
28
3
"
8
2
3
(2
1
4
"
4
"
16
" SS)