Configuring ISDN PRI
Table 3-3
Area
none
Australia
Europe
Japan
North America
Verify
To verify that you have configured the interfaces correctly:
•
Cisco AS5350 and Cisco AS5400 Universal Gateway Software Configuration Guide
3-16
ISDN Service-Provider PRI Switch Types
Keyword
none
primary-ts014
primary-net5
primary-ntt
primary-4ess
primary-5ess
primary-dms100
primary-ni
Enter the show controller t3 command and specify the slot and port numbers. Verify that the
controller is up and that you do not have excessive errors; otherwise your controller might go down
frequently. This could indicate switch problems.
AS5400# show controller t3 1/0
T3 1/0 is up.
Applique type is Channelized T3
No alarms detected.
MDL transmission is disabled
FEAC code received:No code is being received
Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Internal
Data in current interval (270 seconds elapsed):
0 Line Code Violations, 0 P-bit Coding Violation
0 C-bit Coding Violation, 0 P-bit Err Secs
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs
0 Unavailable Secs, 0 Line Errored Secs
0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
Total Data (last 32 15 minute intervals):
0 Line Code Violations, 0 P-bit Coding Violation,
0 C-bit Coding Violation, 0 P-bit Err Secs,
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
0 Unavailable Secs, 0 Line Errored Secs,
0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
Chapter 3
Basic Configuration Using the Command-Line Interface
Switch Type
No switch defined
Australia PRI switches
European, New Zealand, and Asia ISDN PRI
switches (covers the Euro-ISDN E-DSS1
signaling system and is European
Telecommunication Standards Institute or
ETSI-compliant)
Japanese ISDN PRI switches
AT&T 4ESS switch type for the United States
AT&T 5ESS switch type for the United States
NT DMS-100 switch type for the United States
National ISDN switch type