Page 1
1U68REEFRA 1U25BEEFRA 1U42S2SM1FA-2 1U50S2SJ2FA-2 1U25S2SM1FA-2 1U35YEGFRA-1 1U35S2SM1FA-2 1U25YEGFRA-1 1U35YEGFRA-2 1U25YEFFRA-1 1U68WEGFRA 1U35MEEFRA-1 Please read this manual carefully before installation. This appliance is filled with R32. Keep this operation manual for future reference. Manufactured: Qingdao Haier Air Conditioner General Co, Ltd.
Page 3
Warning ..........................1 Indoor/Outdoor Unit Installation Drawings.................. 12 Safety Precautions ........................13 Read Before Installation ......................17 Installation Procedure.......................20 Outdoor Unit Troubleshooting....................25...
Page 4
The air conditioner can not be discarded or scrapped Randomly If you need please contact customer service personnel of Haier to scrap in order to obtain the correct disposal methods. Reusable mechanical connectors and flared joints are not allowed indoor.
CAUTION Do not install the air conditioner at any place where there is danger of flammable gas leakage. In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out. Tighten the flare nut according to the specified method such as with a torque wrench.If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
Page 6
Loading and Unloading/Transporting Management/Storage Requirements The products shall be carefully handled during loading and unloading. Rude and barbarous handling such as kicking, throwing, dropping, bumping, pulling and rolling is not allowed. The workers engaged in loading and unloading must be subject to necessary trainings on the potential hazards caused by barbarous handling.
Page 15
The models adopt HFC refrigerant R32. For installation of the indoor units,refer to the installation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit.)
Page 23
Air outlet Wind direction Cushion rubber 4.Installation dimension(Unit:mm) Power Wiring Terminal Power Wiring Distribution Hole The values of The installation dimension are shown in table 3...
The values of The piping size are shown in table 4 Connection of pipes To bend a pi pe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side rst makes working easier.
Page 27
table6 ceramic type of T 25A/250V. The explosion-proof breaker of the air conditioner should be all-pole switch. The distance between its two contacts should not be no A explosion-proof breaker must be installed.
Page 29
Appendix English Español Italiano Français Deutsch Português Appendix Apéndice Appendice Apéndice Blinddarm Apêndice Tabelle 1 - Die Werte Tabela 1 - Os valores table 1-The values of tabla 1-Los valores de tabella 1-I valori di co2 tableau 1-Les valeurs des CO2-Äquivalents de equivalente de CO2 co2 equivalent (t) co2 equivalente (t)
Page 30
Appendix Polski Türkiye Hrvatski Nederlands dodatek dodatak Bijlage tabela 1 - Warto ci tablo 1-CO2 e de eri tablica 1-Vrijednosti tabel 1-De waarden ekwiwalentu CO2 (t) de erleri (t) CO2 (t) co2 ekvivalenta (t) van co2-equivalent (t) 2 (t) Model Model Model Model...
Page 31